GHP Group Pleasant Hearth SL-4011BL Manual de usuario

WARNING!
Never close the Fireplace Glass Doors while a re is burning in the replace! Excessive
replace temperatures may result which could cause the glass doors to shatter and cause
personal injuries or property damage.
SAVE THIS MANUAL FOR FUTURE REFERENCE
MODEL NUMBER: ______________ SIZE: _______
MODEL NAME: _________________
(This information will be found on your sales ticket and/or carton label.)
REV. 05/27/2022
Linear Aluminum Fireplace Glass Door
Français p. 25
Español p. 13
WARNING: Carefully read this entire manual before you begin installing your Glass Door.
LIT0022
Questions, problems, missing parts? Before returning to your retailer, call our customer
service department at 1-877-447-4768, 8:00 a.m. – 4:30 p.m. CST, Monday – Friday, or
Owner’s Manual
NEVER attempt to use your replace until you rst read and understand the following Safety
Rules that will help prevent possible bodily injury or property damage.
Please check with your local city or municipal code before installing this Fireplace Glass Door.

2
This Fireplace Glass Door is intended for surface mount installation on a masonry replace ONLY
DO NOT use this glass door on a pre-fabricated replace.
To determine the type of replace:
A. Masonry Fireplaces are constructed of brick and mortar with a brick chimney.
B. Pre-fabricated Fireplaces have a metal rebox and a sheet metal duct chimney.
Still not sure? Refer to our helpful video online at https://www.youtube.com/watch?v=CGJdgmoVLWY
A Pre-fabricated Fireplace, also called a Zero Clearance Fireplace, will require a different type of
Glass Door. While Fireplace Glass Doors appear interchangeable, they are not! If your replace is a
factory built pre-fab, Do Not use this rescreen. Check the make and model number of your
pre-fab replace and consult your dealer for the appropriate Fireplace Glass Door.
Please check the chart below to make certain you have purchased the correct Glass Door for your
replace opening.
*HEIGHT INCLUDES A 1.5” RISER BAR (NOT ASSEMBLED). SEE ASSEMBLY
INSTRUCTIONS FOR DETAILS.
Model Overal Door Dimension Fits Openings
Width x Height* Width Height*
SL-4011BL 36 x 29” 31.5” - 35.5” 25.25” - 28.75”
SL-4012BL 36 x 31” 31.5” - 35.5” 27.25” - 30.75 “
SL-4013BL 36 x 33” 31.5” - 35.5” 29.25” - 32.75”
SL-4014BL 40 X 29” 35.25” - 39.5” 25.25” - 28.75”
SL-4015BL 40 X 31” 35.25” - 39.5” 27.25” - 30.75”
SL-4016BL 40 X 33” 35.25” - 39.5” 29.25” - 32.75”
NOTE: This Fireplace Glass Door is designed to surface mount, with an overlap, on the outside of the
replace opening. This unit will cover a range of sizes.
(See the Chart below.)
TABLE OF CONTENTS
Safety Information ......................................................................................................................................3
Package Contents ......................................................................................................................................4
Preparation.................................................................................................................................................5
Installation Instructions...............................................................................................................................6
Care & Maintenance.................................................................................................................................12
Warranty ...................................................................................................................................................12

3
SAFETY INFORMATION
Please read and understand this entire manual before attempting to assemble, operate or install the
product. If you have any questions regarding the product, please call customer service at 1-877-447-4768,
8:00 a.m. – 4:30 p.m., CST, Monday – Friday.
1. NEVER LEAVE YOUR FIREPLACE UNATTENDED WHILE IT IS IN USE.
2. NEVER CLOSE THE FIREPLACE GLASS DOORS WHILE A FIRE IS BURNING IN THE
FIREPLACE. Excessive replace temperatures may result which could cause the glass doors to
shatter and cause personal injuries or property damage. Tempered glass does not imply unbreakable
glass. In the unlikely event of glass failure, it will shatter into small pieces to reduce the risk of
personal injury or property damage.
3. Always keep the wire mesh screen completely closed when the replace is in use, except when
adding wood. A closed screen acts as a safety barrier for sparks.
4. Always conrm that the chimney damper is open before starting a re and during use so that smoke
will not exhaust into the room. Always use the damper control knob(s) located at the bottom of the
rescreen to adjust the draft and re intensity.
5. Always position the rewood grate close to the back wall of the rebox and at least 7” back from the
wire mesh screen. Never build too large of a re, to assure safe use of the replace. Always keep all
combustible materials at least 3’ from the front of the replace when in use.
6. Never put any volatile substance in the replace. Always conrm that volatile liquids such as gasoline,
charcoal starter, lighter uid, lantern fuel, or kerosene are NOT located near the front of the replace.
Only use kindling or prepackaged re starter materials to start a re.
7. Always provide adult supervision for children and pets when the replace is in use, and keep them at
a safe distance to prevent accidental burns. To prevent burns, always wear an insulated mitt before
touching the damper control knobs, door handles, wire mesh screen, glass doors, or door frames
whenever the replace is in use.
8. Never use the replace for incinerating trash, newspapers, or waste materials which may release
toxic/noxious fumes.
9. Never allow cold water or other cold substances to come in contact with the replace doors before
they have cooled completely, as the glass could shatter.
10. Never attempt to dispose of ashes until they have cooled completely, as hot ashes are a potential
source of ignition. Always use the replace clean-out door (if available) for removing the ashes and
always use a metal container for safe disposal.
WARNINGS

4
PART DESCRIPTION QTY. PART NO.
A 1/4-20 X 1/4” Machine Screw 2 10-09-115
B 1/4-20 X 1/2” Thread Cutting Screw 2 10-09-116
C 1/4-20 X 2” Thumbscrew (for lintel clamp) 2 10-09-117
D Lintel Clamp 2 10-04-122
E Key Bracket 2 10-04-123
F Pressure Bracket 2 10-04-124
G 1/4-20 X 3 1/2” Thumbscrew (for pressure bracket) 2 10-09-120
H 36” Riser Bar (SL-4011BL, SL-4012BL, SL-4013BL) 1 10-07-452
H 40” Riser Bar (SL-4014BL, SL-4015BL, SL-4016BL) 1 10-07-453
PACKAGE CONTENTS
Some parts and specications may change without notice.

5
PREPARATION
NEUTRALIZE THE HEARTH:
Newly-built replaces often contain a residue of acid used during construction. If allowed to remain in the
pores of the brick, this acid will release a gas that rusts iron and creates pitmarks or red spots. If your
builder has not neutralized the replace, follow these instructions prior to installing your Glass Door:
1. Brush a mild solution of household ammonia on all brick, stone, or cement
surfaces in your replace.
2. Remove all neutralizing solution by rinsing thoroughly with warm water,
followed by several cool rinses.
Before beginning assembly of product, make sure all parts are present. Compare parts with the package
contents list. If any part is missing or damaged, do not attempt to assemble the product. Contact
customer service for replacement parts.
Estimated Assembly Time: 60 minutes
TOOLS REQUIRED:
Phillips and Flathead Screwdrivers, Measuring Tape
CAUTION
THIS UNIT IS HEAVY. Two people are required for safe assembly.

6
INSTALLATION INSTRUCTIONS
Carefully remove all contents from the carton
and place the Fireplace Glass Door on a at,
padded surface to avoid damaging the nish.
Always lift the door by the sides, not the top
frame. Check the included hardware against
the parts list.
If you are missing parts, please call GHP
customer service at 1-877-447-4768.
CAUTION: Before installing the Glass
Door, make sure the replace is cool.
STOP! Please refer to our installation video at:
https://www.youtube.com/watch?v=reR-LUvl62g
1. This step may NOT be necessary!
The frame height (shown on Page 2) includes
a 1.5” riser bar. If your replace opening height
matches the dimensions noted below, DO NOT
ATTACH THE RISER BAR:
If the riser bar is required, lay the door face
down on a at, padded surface. Attach the
riser bar with two included Machine Screws as
shown in Figure 1. Use caution to protect your
hands from possible sharp metal edges. The
back edges of the riser bar and the back edges
of the bottom frame should be ush. In some
cases, the riser bar will extend in front of the
assembly frame which is correct.
NOTE: If your frame does not require a riser
bar, the riser bar and included hardware may
be discarded.
BOTTOM OF DOOR
1
Model Opening height
SL-4011BL 27 1/4”
SL-4012BL 29 1/4”
SL-4013BL 31 1/4”
SL-4014BL 27 1/4”
SL-4015BL 29 1/4”
SL-4016BL 31 1/4”
NOTE: In some models, a riser bar is provided with two sets of holes (top and bottom).
For proper ush t, use the top or bottom set of holes, whichever are suitable to your
frame. Remember that proper ush means the back edges of the riser bar and the back
edges of the bottom frame assembly are even. In some cases, the riser bar will extend in
front of the frame assembly, which is correct.

7
INSTALLATION INSTRUCTIONS
2. The lintel bar is the “L” shaped angle iron that
supports the bricks along the top of the replace
opening. This bar is built into your masonry
replace when originally constructed. Measure
the width of the lintel bar. If the lintel bar is
less than 3” or more than 4” wide, refer to the
Alternative Mounting Method Instructions
(Page 8) and skip steps 2-5 in this section.
To determine the proper bracket assembly for
your replace, measure the distance from the
bottom of the Lintel Bar to the bottom of the
replace. Use this measurement to determine
where the Lintel Bar will line up with the slotted
brackets on the back of your frame. If the
measurement reaches the top of the slotted
brackets, follow Bracket Assembly A. If the
measurement is not the same height as the
slotted brackets, follow Bracket Assembly B.
Assemble the Key Bracket (E) to the lintel clamp
(D) with the 1/4-20 x 1/4” Machine Screw (A).
Do not tighten. Thread 1/4-20 x 2” Thumbscrew
(C) into lintel clamp. Do not tighten.
Bracket Assembly A
Lintel Bar
Bracket Assembly B
2
3. While keeping the door panels fully open,
place the Glass Door against the replace.
Place the “T” head of the Key Bracket (E) into
the slotted bracket on the back of the door as
shown in the inset and turn bracket assembly
to horizontal position as shown in Figure 3.
Repeat on opposite end.
Bracket
Assembly A
Bracket
Assembly B
3

8
INSTALLATION INSTRUCTIONS
4. Center the Glass Door against the replace
opening. (A second person may be necessary
to hold the door tightly against the replace
opening.) Reach inside and slide the Lintel
Clamp (D) back or forward until the lip of
the Lintel Clamp (D) is rmly against the
lintel bar. Tighten the 1/4-20 x 1/4” Machine
Screw (A). Making sure the Glass Door is
against the replace, tighten the 1/4-20 x 2”
Thumbscrew (C) until the door is secure on
top as shown in Figure 4.
Repeat on opposite end.
5. Insert 1/4-20 x 3 1/2” Thumbscrew (I) into
Pressure Bracket (H). Insert Pressure Bracket
(H) into the pair of holes closest to the side
of the replace opening. Making sure the
Thumbscrew (I) is pointing towards the sidewall
of the replace, tighten the Thumbscrew (I) into
the wall. Repeat on opposite end.
4
5

9
INSTALLATION INSTRUCTIONS
6. There are four door panel hinges (two in
the top track and two in the bottom track).
The door panel hinges are designed to be
adjusted. If the door panels are not evenly
aligned or if there is too much space
between the center of the door panels
(when they are in a closed position), you
may adjust them as follows:
Open the door panels. Reach inside and
loosen the panel hinge screws. Do not
remove the screws. Slide the door panel
hinges left or right until the space between
the center of the door panels is even, as
shown in Figure 6.
Return door panels to their original
position.Carefully maintain the door panel
hinge position and tighten screws.
6

10
INSTALLATION INSTRUCTIONS
1A. There are two slotted brackets attached to
the back of the glass door frame (at the top).
Attach a Key Bracket (E) to each of
the slotted brackets as in Figure 1A. Place
the glass door against the replace opening,
center it, and mark the lintel bar through the
slots in the Key Brackets (2 places). (A
second person may be necessary to
hold the door tightly against the replace
opening.) Remove the glass door and drill a
7/32” hole at each location marked. (Wear
your safety glasses while drilling.) Place the
glass door against the replace opening and
align the holes with the slot in each Key
Bracket (E). Use 1/4-20 x 1/2” Thread
Cutting Screws (B) to attach both Key
Brackets to the lintel bar.
2A. Insert 1/4-20 x 3 1/2” Thumbscrew (I) into
Pressure Bracket (H). Insert Pressure
Bracket (H) into the pair of holes closest to
the side of the replace opening. Making
sure the Thumbscrew (I) is pointing towards
the sidewall of the replace, tighten the
Thumbscrew (I) into the wall. Repeat on
opposite end.
ALTERNATIVE MOUNTING METHOD (for top of glass door)
ADDITIONAL TOOLS REQUIRED:
Electric Drill, 7/32” High Speed Steel Bit, Pencil, and Safety Glasses
1A
2A
Este manual sirve para los siguientes modelos
5
Tabla de contenidos
Idiomas:
Otros manuales de Accesorios para chimeneas de GHP Group
Manuales populares de Accesorios para chimeneas de otras marcas

Bronpi
Bronpi KIT-1 Manual de usuario

Town & Country Fireplaces
Town & Country Fireplaces 22150051 Manual de usuario

Travis Industries
Travis Industries 33 DVI Manual de usuario

Superior
Superior ASD3628-TI Manual de usuario

pleasant hearth
pleasant hearth OFP28WG Manual de usuario

IHP
IHP Astria Series Manual de usuario