CAUTION
1. WHEN DEVICE IS IN USE, DO NOT LOOK DIRECTLY INTO THE LASER BEAM–PERMANENT EYE DAMAGE MAY RESULT.
2. USE EXTREME CAUTION WHEN OPERATING THE LASER.
3. NEVER POINT THE DEVICE TOWARDS ANYONE’S EYES.
4. KEEP OUT OF REACH OF ALL CHILDREN
STORAGE & CLEANING
It should be stored at room temperature. The sensor lens is the most delicate part of the thermometer. The lens should be kept
clean at all times, care should be taken when cleaning the lens using only a soft cloth or cotton swab with water or medical
alcohol, allowing the lens to fully dry before using the thermometer. Do not submerge any part of the thermometer.
LCD ERROR MESSAGES
The thermometer incorporates visual diagnostic messages as follows:
‘Hi’ or ’Lo’ is displayed when the temperature being measured is outside of the settings of HAL and LAL.
‘Er2’ is displayed when the thermometer is exposed to rapid changes in the ambient temperature. ‘Er3’ is displayed
when the ambient temperature exceeds 0℃ (32° ) or +50℃ (122° ). The thermometer should be allowed plenty of
time (minimum 30 minutes) to stabilize to the working/room temperature.
Error 5~9, for all other error messages it is necessary to reset the thermometer. To reset it, turn the instrument off,
remove the battery and wait for a minimum of one minute, reinsert the battery and turn on. If the error message
remains, please contact the Service Department for further assistance
BATTERIES
The thermometer incorporates visual low battery indication as follows
When the ‘Low Battery’ icon indicates the battery is low, the battery should be replaced immediately with AAA, 1.5V batteries.
Please note: It is important to turn the instrument off before replacing the battery otherwise the thermometer may malfunction
Dispose of used battery promptly and keep away from children.
SPECIFICATION
Item Non-contact Infrared Scan function Thermocouple Probe Scan function (K type; a
bead wire included.)
Measurement Range -35 ~ +1500℃ K Type: -64 ~ +1400℃
Bead: -50 ~ +250℃
Operating Range 0 ~ 50℃
Accuracy ±2% of reading or 2℃ ±2% ±1% of reading or 1℃
Emissivity Range 0.1 ~ 1.0 (Default 0.95)
Response Time 1 sec
D:S (Distance:Spot) 75:1
Memory Detailed 24 Memories with Temperature & Emissivity
Battery Life min 140 hours continuous use (Alkaline, without Laser and Back Light.)
Dimensions 204.14 x 179.19 x 58.40mm
Weight 355g
including batteries (AAA*2pcs)
Note: Under an electromagnetic field of 3V/m from 700 to 1,000 MHz the maximum error is ±30°C (54 º ),
from 1.4~1.5 GHz the maximum error is ±6 °C (10.8 º ).
EMC/RFI
: Readings may be affected if the unit is operated within radio frequency electromagnetic field strength of
approximately 3 volts per meter, but the performance of the instrument will not be permanently affected.
‘Battery Exhausted’:
measurements are not possible
‘Battery Low’: battery needs to be replaced,
measurements are still possible
‘Battery OK’: measurements
are possible