FuturePlus Systems FS2010 Manual de usuario

FuturePlus Systems Corporation
FS2010 Users Manual
For use with Agilent Logic Analyzers
Revision – 1.2
Copyright 2005 FuturePlus® Systems Corporation
FuturePlus is a trademark of FuturePlus Systems Corporation

2
How to reach us ......................................................................................... 4
Product Warranty....................................................................................... 5
Limitation of Warranty...................................................................................5
Exclusive Remedies....................................................................................................5
Assistance..........................................................................................................5
Introduction................................................................................................ 6
How to Use This Manual .................................................................................6
Analyzing the PCI-X Local Bus................................................................ 7
Accessories Supplied........................................................................................7
Minimum Equipment Required......................................................................7
Additional Equipment Required.....................................................................7
Signal Naming Conventions............................................................................8
Determining which logic analyzer card is the Master...................................8
Configuration Files...........................................................................................9
Connecting the 167xx Agilent logic analyzer to the FS2010.......................10
How to install a PCI-X add-in card into the FS2010 ..................................10
System operation with the PCI-X add-in card ............................................10
Setting up the 167xx Analyzer.......................................................................11
Setting up the 1680/90/900 Analyzer............................................................12
1680/90/900 Licensing....................................................................................12
Loading 1680/90/900 configuration files ......................................................12
Connecting the 1680/90/9xx Agilent logic analyzer to the FS2010 ............12
Offline Analysis ..............................................................................................13
The Format Menu..........................................................................................16
The PCI-X Transaction Decode Software....................................................17
FS2010 Software and Timing mode........................................................ 18
The ADDR, ADDR_B and DATA variables............................................................18
The CYCLE variable................................................................................................19
Bit Re-ordering.........................................................................................................20
State Analysis ........................................................................................... 21
Acquiring Data...............................................................................................21
Configuring the Workspace for PCI-X Analysis.........................................22
The State Listing Display...............................................................................23
Functionality of the FS2010 Transaction Decode Software .......................25
Timing Analysis ....................................................................................... 26
Acquiring Data...............................................................................................26
The Waveform Display..................................................................................27

3
Use of EyeFinder/Eyescan.............................................................................27
Transaction Viewer.................................................................................. 28
General Information................................................................................ 29
Characteristics................................................................................................29
State/Timing Adapter Probe Interface Compatibility...............................................29
Card Edge Extender Connector ................................................................................29
Standards Supported.................................................................................................29
Power Requirements.................................................................................................29
Logic Analyzer Required..........................................................................................29
Number of Probes Used............................................................................................29
Minimum Clock Period (State).................................................................................29
Etch length................................................................................................................30
Operations.................................................................................................................30
Environmental Temperature .....................................................................................30
Altitude.....................................................................................................................30
Humidity...................................................................................................................30
Testing and Troubleshooting....................................................................................30
Servicing...................................................................................................................30
Signal Connections.........................................................................................30
The State/Timing Adapter Probe interface pinout....................................................30
J2 Signal Connector ................................................................................ 31
J3 Signal Connections............................................................................. 33
J4 Signal Connections............................................................................. 35

4
How to reach us
For Technical Support:
FuturePlus Systems Corporation
36 Olde English Road
Bedford NH 03110
TEL: 603-471-2734
FAX: 603-471-2738
On the web http://www.futureplus.com
For Sales and Marketing Support:
FuturePlus Systems Corporation
TEL: 719-278-3540
FAX: 719-278-9586
On the web http://www.futureplus.com
FuturePlus Systems has technical sales representatives in several
major countries. For an up to date listing please see
http://www.futureplus.com/contact.html.
Agilent Technologies is also an authorized reseller of many
FuturePlus products. Contact any Agilent Technologies sales office
for details.

5
Product Warranty
This FuturePlus Systems product has a warranty against defects in material and
workmanship for a period of 1 year from the date of shipment. During the
warranty period, FuturePlus Systems will, at its option, either replace or repair
products proven to be defective. For warranty service or repair, this product must
be returned to the factory.
Due to the complex nature of the FS2010 and the wide variety of customer
target implementations, the FS2010 has a 30 day acceptance period by the
customer from the date of receipt. If the customer does not contact
FuturePlus Systems within 30 days of the receipt of the product it will be said that
the product has been accepted by the customer. If the customer is not satisfied
with the FS2010 they may return the FS2010 within 30 days for a refund.
For products returned to FuturePlus Systems for warranty service, the Buyer
shall prepay shipping charges to FuturePlus Systems and FuturePlus Systems
shall pay shipping charges to return the product to the Buyer. However, the
Buyer shall pay all shipping charges, duties, and taxes for products returned to
FuturePlus Systems from another country.
FuturePlus Systems warrants that its software and hardware designated by
FuturePlus Systems for use with an instrument will execute its programming
instructions when properly installed on that instrument. FuturePlus Systems does
not warrant that the operation of the hardware or software will be uninterrupted or
error-free.
The foregoing warranty shall not apply to defects resulting from improper or
inadequate maintenance by the Buyer, Buyer-supplied software or interfacing,
unauthorized modification or misuse, operation outside of the environmental
specifications for the product, or improper site preparation or maintenance. NO
OTHER WARRANTY IS EXPRESSED OR IMPLIED. FUTUREPLUS SYSTEMS
SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
THE REMEDIES PROVIDED HEREIN ARE BUYER’S SOLE AND EXCLUSIVE
REMEDIES. FUTUREPLUS SYSTEMS SHALL NOT BE LIABLE FOR ANY
DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL
DAMAGES, WHETHER BASED ON CONTRACT, TORT, OR ANY OTHER
LEGAL THEORY.
Product maintenance agreements and other customer assistance agreements
are available for FuturePlus Systems products. For assistance, contact
Technical Support.
Limitation of
Warranty
Exclusive Remedies
Assistance

6
Introduction
The FS2010 is a 32/64 bit, 0 to 133Mhz PCI-X State and Timing adapter probe
for use with Agilent logic analyzers. This card has a universal card edge
connector and a 3.3v extender card connector. The FS2010 PCI-X State/Timing
adapter probe and extender card performs three functions.
•The first is to act as an extender card, physically extending a module up
approximately 1.5 inches from the motherboard connector.
•The second is to provide a complete timing analysis interface between any
PCI-X add-in slot and Agilent Logic Analyzers.
•The third is to provide a complete state analysis interface and software
decode of the PCI-X traffic between any PCI-X add-in slot and Agilent Logic
Analyzers.
The State/Timing Adapter Probe interface is a passive bus monitor which does
not assert any signals on the PCI-X bus. Because the FS2010 interface does
not actively buffer the PCI-X bus signals, negligible skew is introduced.
The configuration software on the diskette sets up the format menu of the logic
analyzer for compatibility with your PCI-X bus.
This manual is organized to help you quickly find the information you need.
•Analyzing the PCI-X Local Bus chapter introduces you to the FS2010 and
lists the minimum equipment required and accessories supplied for PCI-X
bus analysis.
•The State Analysis chapter explains how to configure the FS2010 to
perform state analysis on your PCI-X bus.
•The Timing Analysis chapter explains how to configure the FS2010 to
perform timing analysis on your PCI-X bus.
•The General Information chapter provides information on the operating
characteristics, the test point and cable header pinout and the mechanical
drawing for the FS2010 module.
How to Use This
Manual

7
Analyzing the PCI-X
Local Bus
This chapter introduces you to the FS2010 and lists the minimum
equipment required and accessories supplied for PCI-X Local Bus
analysis. This chapter also contains information that is common to both
state and timing analysis.
The FS2010 product consists of the following accessories:
•The FS2010 probe.
•1 Diskette containing the configuration files and the FS2010 PCI-X
decoder for 167xx analyzer.
•A CD containing the setup file to install the configuration files and
protocol decoder on the 1680/90/900 analyzer or to use as an offline
viewer.
•This operating manual on CD, Quick Start sheet, and SW
Entitlement certificates for the software.
The minimum equipment required for analysis of a PCI-X Local Bus
consists of the following equipment:
•Agilent 16700 analysis frame with the 16715 analyzer card or better.
•Revision 2.80.00 or better of the Agilent Logic analysis frame
software.
•1680/90/900 Logic analyzer or PC containing Agilent 1680/90/900
OS version 3.00.00 or better.
•The FS2010 Product
•A PCI-X target bus
The type of logic analyzer card used will determine the correct type of
termination adapter needed. For analyzer cards that use the 40 pin
header, 1671x, 1674x, 16750/1/2, 1691x you will need the E5385A
(FuturePlus number is FS1015) termination adapter cables. For
analyzer cards that use the 90 pin header, 16753/4/5/6, 1695x you will
need the E5378A (FuturePlus number is FS1014) termination adapter.
A total of 3 adapter cables are required for 64 bit data width capture.
Accessories
Supplied
Minimum Equipment
Required
Additional
Equipment Required

8
This operating manual uses the same signal notation as the PCI-X
LOCAL BUS SPECIFICATION - REVISION 1.0 That is, a # symbol at the
end of a signal name indicates that the signal’s active state occurs when
it is at a low voltage. The absence of a # symbol indicates that the signal
is active at a high voltage.
When connecting the logic analyzer cards to the FS2010 it is necessary
to know which logic analyzer card in which slot has been configured as
the Master and which one has been configured as the Expander. Refer
to the SYSTEM view of your 1670x or 1690x mainframe to determine
how the cards have been configured.
Signal Naming
Conventions
Determining which
logic analyzer card is
the Master

9
*For 32 bit analysis load the timing or state configuration file into a single
logic analyzer card. If you are using a 16910 card then only one card is
required for 64 bit analysis.
Configuration Files
167xx Analyzer 169xx Analyzer File name for
State/Timing Analysis Description
16715/6/7/9 or
1674X or
16750/1/2
1680/90,
16750/1/2,
1691x
CP210_1 *2 card state
analysis
16715/6/7/9 or
1674X or
16750/1/2
1680/90,
16750/1/2,
1691x
CP210_2 *2 card timing
16715/6/7/9 or
1674X or
16750/1/2
1680/90,
16750/1/2,
1691x
CP210_3 1 card eyefinder
config
16753/4/5/6 16753/4/5/6,
1691x CP210_4 1 card eyescan
config

10
The following explains how to connect the logic analyzer to the FS2010
for either state or timing analysis:
1. Connect the logic analyzer PODs 3 adapter cables, either the
E5378A or E5385A depending on the logic analyzer cards used.
2. Plug the Adapter cables into the probe as shown in the table
below.
167XX/1655X PCI-X Analysis Probe
connector Comment
Master POD 1 J2 odd J CLK
Master POD 2 J2 even
Master POD 3 J3 odd
Master POD 4 J3 even
Expander POD 1 J4 odd optional 64 bit
Expander POD 2 J4 odd optional 64 bit
The card edge connector of the FS2010 module can accommodate one
64 or 32 bit 3.3V PCI-X add-in card. To install simply align the module
with the connector and gently push the module in until it is seated in the
connector. There is sufficient clearance for the add-in card front plate.
The FS2010/PCI-X add-in card combination can then be installed in any
slot of the PCI-X Local bus.
When removing the PCI-X add-in card from the card edge extender
connector grasp the FS2010 with one hand and the PCI-X add-in card
with the other. Gently rock the PCI-X add-in card until it is free from the
connector.
The nature of an extender card is that it extends the etch length of the
bus. Due to the sensitivity of some PCI-X designs, extending the etch
length can interfere with the PCI-X add-in card operation. Operation of
the PCI-X add-in card when installed in the card edge extender
connector is not guaranteed.
Connecting the
167xx Agilent logic
analyzer to the
FS2010
How to install a PCI-X
add-in card into the
FS2010
System operation with
the PCI-X add-in card
Tabla de contenidos
Otros manuales de Instrumento de medición de FuturePlus Systems
Manuales populares de Instrumento de medición de otras marcas

Endress+Hauser
Endress+Hauser Proline Promag 50 Especificaciones técnicas

Siemens
Siemens SITRANS F Coriolis FCT030 Manual de lista de piezas

KLINGER
KLINGER CMF V Series Manual de usuario

EXFO
EXFO FTB-2 Manual de operación y mantenimiento

Keysight
Keysight M8290A Manual de usuario

ADTEK
ADTEK MW-5 Manual de usuario












