Furuno PG-700 Manual de usuario

INTEGRATED HEADING SENSOR
PG-700
OPERATOR'S MANUAL
www.furuno.co.jp
MODEL


i
IMPORTANT NOTICES
General
• This manual has been authored with simplified grammar, to meet the needs of the international
users.
• The operator of this equipment must read and follow the descriptions in this manual. Wrong op-
eration or maintenance can cancel the warranty or cause injury.
• Do not copy any part of this manual without written permission from FURUNO.
• If this manual is lost or worn, contact your dealer about replacement.
• The contents of this manual and equipment specifications can change without notice.
• The example screens (or illustrations) shown in this manual can be different from the screens
you see on your display. The screens you see depend on your system configuration and equip-
ment settings.
• Any modification of the equipment (including software) by persons not authorized by FURUNO
will cancel the warranty.
• All brand and product names are trademarks, registered trademarks or service marks of their
respective holders.
How to discard this product
Discardthisproductaccordingtolocalregulationsforthedisposalofindustrialwaste.Fordisposal
in the USA, see the homepage of the Electronics Industries Alliance (http://www.eiae.org/) for the
correct method of disposal.
How to discard a used battery
Some FURUNO products have a battery(ies). To see if your product has a battery(ies), see the
chapter on Maintenance. Follow the instructions below if a battery(ies) is used.
In the European union
The crossed-out trash can symbol indicates that all types of batteries
must not be discarded in standard trash, or at a trash site. Take the
used batteries to a battery collection site according to your national
legislation and the Batteries Directive 2006/66/EU.
In the USA
The Mobius loop symbol (three chasing arrows) indicates that Ni-Cd
and lead-acid rechargeable batteries must be recycled. Take the
used batteries to a battery collection site according to local laws.
In the other countries
The Mobius loop symbol (three chasing arrows) indicates that Ni-Cd and lead-acid rechargeable
batteries must be recycled. Take the used batteries to a battery collection site according to local
laws.
Cd
Ni-Cd Pb

ii
SAFETY INSTRUCTIONS
Instructions for the user
Instructions for the installer
WARNING
Indicates a condition that can cause death or serious injury if
not avoided.
CAUTION
Indicates a condition that can cause minor or moderate injury if
not avoided.
Warning, Caution
Mandatory Action
Prohibitive Action
Read these safety instructions before you operate the equipment.
WARNING
Turn off power at the switchboard if the
equipment is emitting smoke or fire.
Fire or electrical shock can result if the
power remains on
Turn off the power at the switchboard
if you feel the equipment is not
working properly.
If the equipment feels hot or is emitting
odd noises, immediately turn off the power
at the switchboard.
Do not dissassemble or modify the
equipment.
Fire, electrical shock or bodily injury
can result.
CAUTION
Be sure to connect to the correct
power supply.
Connection to a wrong power supply
can cause fire or bodily injury.
Observer the following compass safe
distances to prevent interference to
a magentic compass.
Std. Compass Steering compass
0.3 m 0.3 m
Before doing deviation correction
and heading adjustment, turn off
the autopilot.
The rudder may jerk violently, which
can result in a dangerous situation.
Turn off the power at the mains switch-
board before beginning the installation.
Post a sign near the power switch
indicating it should not be turned while
the equipment is being installed.
Fire, electrical shock or serious injury can
result if the power is left on or is applied
while the equipment is being installed.
Use specified cable to connect the
Junction Box.
Use of the wrong cable can result in
bodily injury and cause fire.
WARNING

iii
TABLE OF CONTENTS
FOREWORD....................................... iv
SYSTEM CONFIGURATION............... v
EQUIPMENT LIST.............................. vi
1. HOW TO INSTALL THE
EQUIPMENT................................. 1
1.1 Installation Considerations ......... 1
1.2 Wiring ......................................... 5
1.3 Compensation of Deviation ........8
1.4 Heading Adjustment.................10
1.5 Input/Output Data List............... 12
2. OPERATION............................... 13
2.1 Key and Lamp Explanation.......13
2.2 How to Turn on the PG-700 .....14
3. MAINTENANCE AND
TROUBLESHOOTING................ 15
3.1 General Maintenance...............15
3.2 Lamp status display .................16
3.3 Troubleshooting .......................17
3.4 How to restore default settings. 17
Specifications............................... SP-1
Outline Drawings.............................D-1
Interconnection Diagram................S-1

iv
FOREWORD
Congratulations on your choice of the PG-700 Integrated Heading Sensor. We are confident you
will see why the FURUNO name has become synonymous with quality and reliability.
For over 60 years FURUNO Electric Company has enjoyed an enviable reputation for innovative
and dependable marine electronics equipment. This dedication to excellence is furthered by our
extensive global network of agents and dealers.
Your equipment is designed and constructed to meet the rigorous demands of the marine envi-
ronment. However, no machine can perform its intended function unless properly operated and
maintained. Please carefully read and follow the operation and maintenance procedures set forth
in this manual.
Features
• Angular velocity sensor and magnetic bearing sensor incorporated.
• Automatic determination of installation site suitability.
• L-shaped mounting base for mounting on bulkhead.
• Output of magnetic bearing data to FURUNO CAN bus device.

v
SYSTEM CONFIGURATION
The solid line below shows the basic system configuration.
SENSOR
PG-700
JUNCTION BOX
FI-5002
*: NavNet 3D, FI series instrument, etc.
**: Not necessary if FURUNO CAN bus network supplies power.
12 VDC**
FURUNO CAN bus Device*

vi
EQUIPMENT LIST
Standard Equipment
Optional Equipment
Name Model Code
number Quantity Remark
Sensor PG-700 - 1
Installation
materials CP64-02800 - 1 set • Cable set
Type: M12-05BM+05BF-060
Code number: 000-167-964-11
Quantity: 1
• Self-tapping screws
Type: 4x16 SUS304
Code number: 000-162-605-10
Quantity: 3
Name Model Code
number Quantity Remark
Junction box FI-5002 000-010-765 1 set
Cable set FI-50-DROP 000-166-945-
11 16m

1
1. HOW TO INSTALL THE
EQUIPMENT
1.1 Installation Considerations
Mount the unit with the lamps and keys face up on a horizontal surface. The unit can be mounted
ona desktoporbulkhead. Overheadmountingisnot allowed.Whenselecting amountinglocation,
observe the following to ensure optimal performance:
• Do not mount in an area where water can collect.
• Mount the unit in an area with a temperate between -15 and +55 °C (5 -131°F).
• Mount the unit in an area with low shock and vibration (near the center of gravity to the hull as
possible).
• Mount far away from any electromagnetic wave sources (radio antennas, etc.).
• Mount horizontally, and not on the ceiling.
• Mount as far away as possible from any magnetic interference and power cables.
• Mount at least 50cm (20”) away from the following:
• Engines, generators, steel fuel and water tanks
• Bilge pump, anchor, anchor chain
• Radio antenna cables
• Metal mast support and keel
• Mount in a location where it is easy to adjust or perform maintenance.
• Mount close to the ship’s draft (do not mount to the mast or Tuna tower).

1. HOW TO INSTALL THE EQUIPMENT
2
Determining the mounting location
After choosing the approximate mounting location to a table or bulkhead, ensure that the location
is suitable to supply power to the unit.
1. Connect the power cable to the unit.
If the sensor unit is connected last to the optional Junction Box FI-5002, cut off the connector
(supplied) of the cable M12-05BM+05BF-060 from the FI-5002 side, and connect the red wire
of the cable to the positive terminal (+) of the battery (12 VDC) and the black wire to the neg-
ative terminal (-).
If you connect PG-700 directly to the instrument, or to a network, each device must be tem-
porarily connected to each other, and a power supply 12 VDC (see page 6).
2. Place the unit at the intended mounting position and supply power. Verify that the STATUS
lamp is not lit red.
If the STATUS lamp illuminates red, there may be a problem with the internal magnetic sen-
sor.
3. Press and hold the [+] and [-] keys simultaneously for seven seconds, and release both keys.
The CHECK lamp blinks, and the CALIB and STATUS lamps turn off.
Ship's Switchboard
Battery
12 VDC
Red Black
CALIB STATUS CHECK
THIS SIDE UP
BOW
PG-700
Flashing (green)
Tabla de contenidos
Otros manuales de Accesorios de Furuno

Furuno
Furuno Precision PG-500 Manual de usuario

Furuno
Furuno FELCOM 16 Manual de usuario

Furuno
Furuno Precision PG-500 Manual

Furuno
Furuno FI-3003 Manual de usuario

Furuno
Furuno DRS4DL Manual

Furuno
Furuno DRS4D Manual de usuario

Furuno
Furuno PG-1000 Manual de usuario

Furuno
Furuno DRS6A X-Class Manual de usuario

Furuno
Furuno DRS4DL+ Manual de usuario

Furuno
Furuno FI-3002 Manual de usuario



















