FujiFilm NA0LA-ET1 Manual de usuario

series
USER’S MANUAL
SPF Ethernet Communication
FEH630

Preface
Notes
1. This manual may not be reproduced in whole or part in any form without prior written approval by the manufacturer.
2. The contents of this manual (including specifications) are subject to change without prior notice.
3. If you find any ambiguous or incorrect descriptions in this manual, please write them down (along with the manual No.
shown on the cover) and contact FUJI.
Thank you for purchasing Fuji Electric Programmable Controller MICREX-SX series SPF.
This User’s Manual describes the following products for the SPF series:
•Ethernet communication expansion board (Type: NA3LA-ET1)
•Ethernet communication expansion unit (Type: NA0LA-ET1)
(These may be collectively referred to as “unit” in this manual.)
This manual consists of General section (Page name with G), Hardware section (Page name with H), and Software section (Page
name with S).
Read this manual carefully to ensure correct operation and also read the corresponding user’s manuals listed below.
* In addition to the above manuals, the following Fuji Electric Co.,Ltd.site offers various manuals and technical documents
associated with MICREX-SX series.
URL http://www.fujielectric.com
Title Manual No. Contents
User’s Manual Hardware,
MICREX-SX series SPF
FEH526 Describesthesystemconguration,hardwarespecicationsand
operations of units in the MICREX-SX series SPF.
User’s Manual Instructions
(for SX-Programmer Standard),
MICREX-SX series SPF
FEH524 Describesthememoryspecicationsandinstructionsspecicto
the MICREX-SX series SPF (for SX-Programmer Standard).
User’s Manual Instructions
(for SX-Programmer Standard),
MICREX-SX series SPH
FEH588 Describesthememory,languageandsystemdenitionsofthe
MICREX-SX series SPH (for SX-Programmer Standard).
User’s Manual SX-Programmer Standard
<Reference>, MICREX-SX series
FEH598 Describes the functions and the operations of SX-Programmer
Standard.
User’s Manual Instructions,
(for SX-Programmer Expert),
MICREX-SX series SPF
FEH525 Describesthememoryspecicationsandinstructionsspecicto
the MICREX-SX series SPF (for SX-Programmer Expert).
User’s Manual Instructions,
(for SX-Programmer Expert),
MICREX-SX series SPH
FEH200 Describesthememory,languageandsystemdenitionsofthe
MICREX-SX series SPH (for SX-Programmer Expert).
User’s Manual SX-Programmer Expert
(D300win) <Reference>, MICREX-SX series
FEH257 Describes the functions and the operations of SX-Programmer
Expert.

Safety Precautions
Be sure to read the "Safety Precautions" thoroughly before using the module.
Here,thesafetyprecautionsitemsareclassiedinto"Warning"and"Caution".
Even some items indicated by "Caution" may result in a serious accident.
Both safety instruction categories provide important information. Be sure to strictly observe these instructions.
Warning
Caution
: Incorrect handling of the device may result in death or serious injury.
: Incorrect handling of the device may result in minor injury or physical damage.
Warning
Neve touch any part of charged circuits as terminals and exposed metal portion while the power is turned ON.
It may result in an electric shock to the operator.
Turn OFF the power before mounting, dismounting, wiring, maintaining or checking, otherwise, electric shock, erratic
operation or troubles might occur.
Place the emergency stop circuit, interlock circuit or the like for safety outside the PLC. A failure of the PLC might break
or cause problems to the machine.
When using an expansion right side unit, be sure to mount a healthy unit to stop the SPF system with a fatal fault if the
expansion right side unit is dropped. Unless a healthy unit is mounted, a dropout of the expansion right side unit is not
detected and the SPF system continues operation in the state where the expansion right side unit is dropped.

Safety Precautions
Do not use one found damaged or deformed when unpacked, otherwise, fire, failure or erratic operation might be caused.
Do not shock the product by dropping or tipping it over, otherwise, it might be damaged or troubled.
Follow the directions of the instruction manual and user’s manual when mounting the product.
If mounting is improper, the product might drop or develop problems or erratic operations.
Use the rated voltage and current mentioned in the instruction manual and user’s manual. Use beyond the rated values
might cause fire, erratic operation or failure.
Operate (keep) in the environment specified in the instruction manual and user’s manual. High temperature, high humidity,
condensation, dust, corrosive gases, oil, organic solvents, excessive vibration or shock, might cause electric shock, fire,
erratic operation or failure.
Select a wire size to suit the applied voltage and carrying current. Tighten the wire terminals to the specified torque.
Inappropriate wiring or tightening might cause fire, malfunction, failure or might cause the product to drop from its
mounting.
Contaminants, wiring chips, iron powder or other foreign matter must not enter the device when installing it, otherwise, fire,
accident, erratic operation or failure might occur.
Remove the dust-cover seals of modules after wiring, otherwise, fire, accident, erratic operation or failure might occur.
Connect the ground terminal to the ground, otherwise, electric shock or erratic operation might occur.
Periodically make sure the terminal screws and mounting screws are securely tightened.
Operation at a loosened status might cause fire or erratic operation.
Put the furnished connector covers on unused connectors, otherwise, erratic operation or failure might occur.
Sufficiently make sure of safety before program change, forced output, starting, stopping or anything else during a run.
Wrong operation might break or cause problems to the machine
Engage the loader connector in a correct orientation, otherwise, an erratic operation might occur.
Before touching the PLC, discharge any static electricity that may have been collected on your body. To discharge it, touch
a grounded metallic object. Static electricity might cause erratic operation or failure.
Be sure to install the electrical wiring correctly and securely, observing the directions of the instruction manual and user’s
manual. Wrong or loose wiring might cause fire, accident or failure.
When disengaging the plug from the outlet, do not pull the cord, otherwiase, break of cable might cause fire or failure.
Do not attempt to change system configurations (such as installing or removing expansion block) while the power is ON,
otherwise, failure or erratic operation might occur.
Do not attempt to repair the module by yourself, but contact your Fuji Electric agent, otherwise, fire, accident or failure
might occur.
To clean the module, turn power off and wipe the module with a cloth moistened with warm water. Do not use thinner or
other organic solvents, as the module surface might become deformed or discolored.
Do not remodel or disassemble the product, otherwise, failure might occur.
Follow the regulations of industrial wastes when the device is to be discarded.
The products covered in this user’s manual have not been designed or manufactured for use in equipment or systems
which, in the event of failure, can lead to loss of human life.
Do not use the products covered in this user’s manual for special applications, such as power plant, radiation facilities,
railroad, space/flight equipments, lifeline facilities, or medical equipments, where a great effect on human life, body,
society, major property or rights may be anticipated and high degree of safety is required.
Be sure to provide protective measures when using the products covered in this manual in equipment which, in the event
of failure, can lead to loss of human life or other grade results.
External power supply (such as 24 V DC power supply) which is connected to DC I/O should be strongly isolated from AC
power supply, otherwise, accident or failure might occur. (Use of EN60950 conforming power supply is recommended.)
Do not use the peoducts covered in this user’s manual in a residential environment.
Caution

Revision
* The manual No. is printed at the bottom right of the cover of this manual.
Printed on * Manual No. Revision contents
Oct. 2017 FEH630 First edition

Contents
Preface
Safety Precautions
Revision
Contents
General Section
Section G1 Introduction to Communication Modes
G1-1 Overview of Communication Modes ..........................................................................................................................G-1
G1-2 Communication Port ..................................................................................................................................................G-4
Hardware Section
SectionH1 HardwareSpecications .......................................................................................................... H-1
H1-1 GeneralSpecications...............................................................................................................................................H-1
H1-2 TransmissionSpecications ......................................................................................................................................H-1
H1-3 Names and Functions................................................................................................................................................H-2
H1-4 External Dimensions..................................................................................................................................................H-4
Software Section
Section S1 Communication Expansion Board/Unit Registration............................................................... S-1
Section S2 Communication Parameters .................................................................................................... S-3
S2-1 Communication Parameter Setting Items ..................................................................................................................S-3
Section S3 General Purpose Communication Mode Details...................................................................... S-5
S3-1 Overview....................................................................................................................................................................S-5
S3-2 SpecicationsofGeneralPurposeCommunicationModeFB...................................................................................S-6
“C_ETHERNET”.............................................................................................................................................................S-6
S3-2-1 FB format.............................................................................................................................................................S-6
S3-2-2 Description of FB terminals .................................................................................................................................S-8
S3-3 Communication Procedures.......................................................................................................................................S-13
Section S4 Loader Communication (Client Operation) Mode Details ........................................................ S-18
S4-1 Overview....................................................................................................................................................................S-18
S4-2 Details of R_READ ....................................................................................................................................................S-18
S4-2-1 Operation of R_READ.........................................................................................................................................S-18
S4-2-2 Format of R_READ .............................................................................................................................................S-19
S4-2-3 Description of R_READ terminals .......................................................................................................................S-21
S4-3 DetailsofR_WRITE...................................................................................................................................................S-22
S4-3-1 OperationofR_WRITE .......................................................................................................................................S-22
S4-3-2 FormatofR_WRITE............................................................................................................................................S-23
S4-3-3 DescriptionofR_WRITEterminals......................................................................................................................S-25
Section S5 Loader Communication (Server Operation) Mode Details....................................................... S-26
S5-1 Overview....................................................................................................................................................................S-26
S5-2 Transmission Data Format of Commands .................................................................................................................S-27
S5-3 Loader Command Details ..........................................................................................................................................S-30
S5-3-1 Data read.............................................................................................................................................................S-30
S5-3-2 Data write ............................................................................................................................................................S-32
S5-3-3 CPU start.............................................................................................................................................................S-33
S5-3-4 CPU initialize and start........................................................................................................................................S-34
S5-3-5 CPU stop.............................................................................................................................................................S-35
S5-3-6 CPU reset ............................................................................................................................................................S-36

Contents
Section S6 Memory Map............................................................................................................................ S-37
S6-1 Communication Parameter Special Register Retain Area ........................................................................................S-37
(forReading/Writing) ......................................................................................................................................................S-37
S6-2 Communication Parameter Special Register Non-retain Area ..................................................................................S-40
(for Reading) ..................................................................................................................................................................S-40
Section S7 Failure Diagnosis ..................................................................................................................... S-43
S7-1 System RAS...............................................................................................................................................................S-43
S7-2 Dump List...................................................................................................................................................................S-44
S7-3 Error Code List...........................................................................................................................................................S-52
S7-3-1 Error code format ................................................................................................................................................S-52
S7-3-2 Error code details for each error type..................................................................................................................S-52

G-1
General Section
Section G1 Introduction to Communication Modes
You can perform Ethernet communication with an external device by connecting a communication expansion board or
communication expansion unit to an SPF series CPU.
Each communication board and communication expansion unit has one physical port. Up to eight logical ports can be used per
physical port. However, if two or more ports are simultaneously used, responses of communication deteriorate.
For details, see “G1-2 Communication Port.”
The following communication modes are available.
(1) General purpose communication
(2) Loader communication (server operation)
(3) Loader communication (client operation)
G1-1 Overview of Communication Modes
(1) General purpose communication
The “general purpose communication” mode allows data sending (or receiving) with external devices by TCP/IP or UDP/IP.
You need to create a communication program on the SPF side. Use “C_ETHERNET” FB.
Connect to communication expansion board/unit
Data receive
External device
Data send

G-2
General Section
(2) Loader communication (server operation)
The “loader communication (server operation)” mode supports TCP/IP only (UDP/IP is not supported). The connections shown
below are available.
1) Connection to POD (MONITOUCH)
No application program for communication is required on the SPF side.
POD
Ethernet connection
Commercially available LAN cable
(cross connection)
Connect to communication expansion board/unit
2) Connection to PC loader
3) Connection to PC by creating a loader protocol communication program on the PC side
PC loader Ethernet connection
Commercially available LAN cable
(cross or straight connection)
Connect to communication expansion board/unit
PC Ethernet connection
Commercially available LAN cable
(cross or straight connection)
Connect to communication expansion board/unit

G-3
General Section
(3) Loader communication (client operation)
The “loader communication (client operation)” mode supports TCP/IP only (UDP/IP is not supported.)
This mode is used to read/write the data memory in target device (SPH or SPF).
“R_READ”(forreadingdata)and“R_WRITE”(forwritingdata)FBsareusedforcommunication.StarttheseFBstosenda
loader command from the self station to the target device.
No communication program is required on the target device since it operates as a server.
IN
OUT
CPU I/O I/O I/O
Connect to Ethernet built in CPU or Ethernet module
Ethernet connection
Commercially available
LAN cable
(cross connection)
Connect to communication expansion board/unit
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Otros manuales de Controladores de FujiFilm