INSTRUCTIONS
Step 4 - Adjusting the Bio Clean ARS Length
Locate the quick release pin on the back of the
Bio Clean ARS unit
Slowly wiggle the center plate and remove it
Cut the measured length of the tension spring &
aperture bar & remove the excess hydrablades
Retread the spring stud and reattach the center
plate and quick release pin
If your installation length is too long, proceed by using a measuring
tape to measure the total amount of excess space that overlaps
the connector plate. This measured length will serve as the cutting
length. There is no need to remove the Bio Clean ARS unit. The
quick release pin can be found on the back of the unit. Simply pull
the quick release pin out so you can detach the excess hydrablades.
Wiggle the center plate back and forth until it becomes loose enough
to be easily removed. Set the center plate aside once it becomes
loose enough.
Using a grinder with a cutting disk, cut the measured length of the
tension spring and remove the excess hydrablades from the unit
until the amount measured is properly removed. Proceed to also cut
the section of the aperture bar until the cut length has been properly
removed.
To easily attach the spring stud onto the tension spring, use the
quick release pin’s midsection to twist the stud clockwise until it
locks into place. Next, reattach the center plate by wiggling it back
and forth until it is securely tightened. Finally, reattach the quick
release pin, and verify that all blades are tightly entact and not loose.