6
On the left-hand side of the boiler there
is a pull-out plastic container used as a
humidifier.
If the air in the room is particularly dry,
pull out the container, fill it with water
and replace it (see fig. 2).
• Turn on the gas cock.
• Press Ion the on/off main switch Aand
the green power light D(green) will come
on.
• Select automatic or manual mode on
the white control on the timer clock (see
1.3.4).
• With automatic mode, set the timer
clock using the red pins.
• Set the required room temperature on
by operating the temperature regulator
C(see 1.3.3).
When the room temperature drops
below the set value, the machine starts
the automatic ignition sequence and the
burner ignites after about 10 seconds.
When the burner is on full power, the
green lights Eand Fcome on. When the
burner is on minimum power only light
Eis on.
Power selection is automatic.
fter a long period of inactivity,
particularly with LPG models, the radiator
may be difficult to start up due to air in
the pipes. This means that the radiator
may shut down once. or twice, in which
case it is necessary to press the reset
button Lto restart.
If a malfunction occurs, the radiator shuts
down automatically.
This is indicated by two alarm signals:
• Check that the gas cock is on, then
switch on a gas ring to check the gas
supply.
• Wait three minutes, then reset the
radiator by pressing the reset button L.
If the radiator still does not start up after
the second attempt, contact a Service
Centre for assistance.
Always check that the grilles and the
air- intake and flue terminal are free from
obstructions such as foreign bodies,
material or the like. Also make sure that
the radiator is not covered by a curtain or
anything else preventing air circulation
2)
With this type of shutdown, which
is generated by a malfunction of the
electrical part, press button Ato switch
off and contact a technical Service Centre.
If this shutdown occurs due to an electric
fault, turn switch Aoff and contact the
Technical Service.
This radiator comes with a temperature
probe that measures the temperature in
the room of installation.
The desired temperature can be selected
by turning knob C.
The range that can be selected is from
5°C (postion 0) to 35°C (position 4).
Turn fully anti-clockwise to activate
the frost protection function, which
restarts the radiator whenever the room
temperature drops below 5°C.
It is possible to connect the device
to an ambient thermostat (or timed
thermostat) able to directly control the
operation (see paragraph 3.4 for the
electric connection).
In this case, for a correct device operation
it is necessary to turn knob Cto position
4. In case of a timed thermostat it is
necessary to place the programming
clock on the machine in the manual
operation position I(par. 1.3.4, fig. 5).
fig. 2