- FLOW METER CONSTATN –measuring of the fuel flow –if you use a flow sensor designed
for your engine, set the number of pulses per one liter of petrol
- TEMPERATURE SENSORS ACTIVATION –setting of four temperature inputs 0-1200°C. If
the sensor is not connected, the temperature of measuring module, i.e. temperature in the
area where the measuring is situated, is displayed. If you do not want to display these
temperatures because of better clarity on the screen, deactivate the appropriate temperature
input –there will be only dashes instead of numbers.
- TEMPERATURE UNIT –setting of the thermometer unit - °C or °F.
- CONSUMPTION UNIT –setting of the consumption unit –liter / hour or gallon / hour.
After this basic setup we recommend to set alarms for individual positions–MAIN MENU –ALARMS
- TEMPERATURE ALARMS –set the alarm on all five temperature inputs, if the set value is
exceeded the temperature will be highlighted on the display and the display will be also
flashing
- PRESSURE ALARM –set the alarm at the pressure input, if the pressure falls below the set
level, the concerned value will be highlighted and the display will be flashing
- FUEL ALARM –set the boundaries of the reserve in the fuel tank, when it falls below the set
level the fuel gauge field will be highlighted and the display will be flashing
- ACCU ALARM –watching of battery voltage –battery charging during flight –when you set
an appropriate value of the battery the fall below the set level will be indicated –if the battery
is not charging it will be highlighted on the display and the display will be flashing
Anytime during the flight it is possible to switch off the light alarm by pressing a
button ESC for 1 second. Another triggered alarm will be lightly active and it is
possible to switch it off again.
The device settings described above are fundamental and necessary for proper
functioning!!!
Other values that you can change or delete which serve for your information:
ENGINE WORKING TIMERS –there are used 4x timers
- ACTUAL –used to measure the engine running, it resets itself automatically by switching the
device off. This timer is displayed on the basic display.
- TOTAL –used to a complete measurement of the engine running and it is not possible to
reset it –information about how many hours have been flown
- TIMER 2 A 3 –serves for your measurement and you can reset it according to your needs
- TIME TO SERVICE –you can set a time of a service inspection of your engine and this value
will be subtracted and displayed every time you switch the device on.
MAXIMUM VALUES –maximum recorded values of temperature and revs which you can reset
according to your needs
FUEL CONSUMPTION –shows the current consumption which can be also seen on the basic
display, average fuel consumption, the amount of fuel consumed and time during which the
measurement was performed. These values can be reset according to your needs.