Flomec QSI Manual de usuario

1
QSI COVER PLATE TRANSMITTER
For FLOMEC® G2 Meters
01/2022 920905-03 Rev. B
Product Owner’s Manua EN
NN

2
Please save these instructions for future reference. Read carefully before
attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to
comply with instructions could result in personal injury and/or property
damage.
Please refer to back cover for information regarding this product’s warranty
and other important information.
DO NOT RETURN THIS PRODUCT TO THE STORE!
Please contact Great Plains Industries, Inc.® before returning any product.
If you are missing parts, or experience problems with your installation,
contact our Customer Support Department. We will be happy to assist you.
Ca : 888-996-3837 or 316-686-7361
Emai : meters@gp ains.com
SAVE FOR YOUR RECORDS
Model #: ______________________
Serial #: ______________________
Purch. Date: ___________________

3
TABLE OF CONTENTS
Getting Started ----------------------------------------------- 4
Introduction ---------------------------------------------------- 4
General Information ------------------------------------ 4
Important Notice ---------------------------------------- 4
Safety ------------------------------------------------------ 4
Installation ----------------------------------------------------- 5
Wiring ------------------------------------------------------ 5
Strain Reliefs -------------------------------------------- 5
NPT Adapters ------------------------------------------- 5
Terminal Connections Chart ------------------------- 6
QSI1 Wiring ---------------------------------------------- 7
QSI2 Wiring ---------------------------------------------- 8
QSI3 Wiring ---------------------------------------------- 9
FLOMEC App for Android -------------------------------- 11
Temperature Probes -------------------------------------- 11
Installation & Wiring ---------------------------------- 11
Maintenance ------------------------------------------------- 12
Replacing Battery ------------------------------------- 12
Specifications ----------------------------------------------- 14
Approval Ratings ------------------------------------------- 15
Service -------------------------------------------------------- 15
Returning Parts ---------------------------------------- 15
Warranty ------------------------------------------------------ 16

4
UNPACKING/INSPECTION
Inspect
•
After unpacking the unit, inspect carefully for any damage that may
have occurred during transit. Check for loose, missing or damaged
parts. Shipping damage claims must be filed withcarrier.
•
See General Safety Instructions, and all Cautions, Warnings, and
Dangers as shown.
INTRODUCTION
The QSI communications module is a multiple capability electronics package. For
the G2 meter, the module is available with the plain cover plate only. The QSI
module has three versions (QSI1, QSI2 or QSI3) available; each with its own mix
of capabilities to better serve the customer (See Versions below).
•
QSI1 is equipped with Bluetooth®, coil/digital pulse input, pulse output (flow or
energy & scalable), RS485 (Modbus® RTU), temperature inputs, BTU
calculator.
•
QSI2 is equipped with Bluetooth, coil/digital pulse input, pulse output (flow or
energy & scalable), temperature inputs, BTU calculator.
•
QSI3 is equipped with Bluetooth, coil/digital pulse input, pulse output (flow
scalable), 4-20mA output.
This manual contains information and meter wiring diagrams for the three different
QSI electronics modules.
IMPORTANT NOTICE
QSI module electronics are very sensitive to electric noise if operated within 6
inches of some electric motors, relays, transformers or other sources of electronic
noise.
If the QSI electronics are used in a manner not specified by the manufacturer, the
protection provided by the equipment may be impaired.
GENERAL INFORMATION
QSI electronics are mounted into the cover plate of the meter you ordered. The
QSI electronics converts the voltage (or pulses) from the meter into usable
information.
The QSI module electronics is powered by customer supplied external power.
SAFETY
•This product is not approved for use in hazardous locations.
•Be sure O-rings and seals are kept in good repair.
•When applying power, adhere to specifications in this manual.
•Disconnect external power before attaching or detaching input or output wires.

5
INSTALLATION
CAUTION: Installation near high electromagnetic fields and high current fields is
not recommended and may result in inaccurate readings.
NOTE: There is no external visual difference between QSI1, QSI2, or QSI3
communications suites when they are installed.
NOTE: If you ordered a QSI communications suite with your meter, it was installed
at the factory. Please review and thoroughly understand all manuals and
installation instructions before proceeding.
WIRING
All electronic options are associated with a flat style of meter cover plate. This
cover plate has four threaded ports, compatible with PG7 threads, for gaining
wiring access to the electronics inside the cover plate.
The meter is shipped with the ports environmentally sealed with a threaded plug
and seal. Remove one or more of these plugs as required to install the supplied
port fittings below.
Each meter is supplied with cable gland strain reliefs with O-rings and 1/2 NPT
adapters with seals for use in the threaded ports of the meter cover plate.
Select the port fittings that fit your process and replace the threaded plugs in the
cover plate with the fittings as required.
NOTE: The threaded plugs installed at the factory may be left in any unused cover
plate port indefinitely.
It is recommended that a “removable” thread-locker (fluid, stick, tape, spray, etc.)
be used when installing the strain reliefs or adapters into the cover plate ports.
STRAIN RELIEFS
The cable gland strain reliefs will accommodate a cable diameter of 0.11 - 0.26
inches (2.79 - 6.6mm) and provide an environmental seal around the cable when
the dome-nut is tightened.
NPT ADAPTERS
The 1/2 NPT adapter fittings are used for attaching flex conduit to the meter, for
those applications that require cable runs to be enclosed in conduit.
NOTE: Cable to be provided by customer to accommodate job requirements.
Cable is not included with meter.

6
INSTALLATION – (continued)
TERMINAL CONNECTIONS CHART
Figure 1
TEMP SENSOR
PT100-Red Sensor VCC Output
PT100-White Input High Side
PT100-Blue Input Return
RS-485 (Galvanically Isolated)
RS485 (+) Positive Signal
RS485 (-) Negative Signal
RS485 GND Circuit Ground*
PULSE INPUT
+5V 5VDC output to power
external sensor
(+) Digital Pulse Frequency
Input, up to 3kHz
(-) Digital Pulse Return
4-20mA (Galvanically Isolated)
(+) 4 to 20mA current loop-
current in to transmitter
(-) 4 to 20mA current loop-
current out of transmitter*
*NOTE: It is not recommended to connect
isolated ground connections together or to
board common.
Coil A Low level sine wave input
Coil B Low level sine wave input
GPI SENSOR
Ribbon cable connection to GPI custom
sensor designs
PULSE OUTPUT
(Galvanically Isolated)
(-) Pulse Output return
current*
(+)
Pulse Output frequency
output. This is a “current
sinking open collector”
output ***
POWER INPUT
-) 12-36VDC Input A**
(+) 12-36VDC Input B**
**NOTE: Polarity of voltage for DC is not
important. However, an earth ground
isolated power supply is required to
prevent earth ground loop currents and
ground fault conditions.
***NOTE: This output may require an
external pull up resistor if interfacing
equipment does not include one.

7
QSI1 WIRING
QSI VERSION 1 – PC BOARD
RS-485
BTU
Figure 2
QSI VERSION 1 - WIRING DIAGRAM
Inputs: Temperature Sensors, Variable Reluctance, Pickup Coil
Outputs: RS-485, Pulse Output
Figure 3

8
QSI2 WIRING
QSI VERSION 2 – PC BOARD
Pulse In
BTU
Figure 4
QSI VERSION 2 - WIRING DIAGRAM
Inputs: Temperature Sensors, Variable Reluctance, Pickup Coil
Output: Pulse Output
Figure 5

9
QSI3 WIRING
QSI VERSION 3 – PC BOARD
4-20mA
Figure 6
QSI VERSION 3 - WIRING DIAGRAM
Customer Equipment with Built-in Power Supply
Inputs: Standard Remote Sensor (Variable Reluctance Pickup Coil)
Outputs: Customer Equipment, 4-20mA Sensing, Built-in Loop Power Supply
Minimum signal amplitude required for
normal operation is approximately 15mV P-
P. Recommended cable type - twisted pair
with shield. Recommended maximum cable
length - 20ft.
CAUTION: When reassembling the cover plate, make sure the enclosure seal is not crimped or twisted.
Do not over-tighten screws (hand-tighten only).
Figure 7

10
QSI3 WIRING - (continued)
QSI VERSION 3 - WIRING DIAGRAM
Customer Equipment without Built-in Power Supply
Inputs: Standard Remote Sensor (Variable Reluctance Pickup Coil)
Outputs: 4-20mA with Separate Power Supply
Note: Either of the wiring diagrams below (Low Side Negative Wiring-Figure 8A) or
(High Side Positive Wiring-Figure 8B) are valid, as long as the current direction arrows
and the (+) and (-) connections on all of the equipment in the loop are correct.
Figure 8A
Low Side (Negative) Wiring
Figure 8B
High Side (Positive) Wiring
Tabla de contenidos
Manuales populares de Transmisor de otras marcas

Dejero
Dejero EnGo 3x Manual de usuario

Rosemount
Rosemount 4600 Manual de usuario

Speaka Professional
Speaka Professional 2342740 Manual de usuario

trubomat
trubomat GAB 1000 Manual de usuario

Teledyne Analytical Instruments
Teledyne Analytical Instruments LXT-380 Manual de usuario

Rondish
Rondish UT-11 Manual de usuario