Press and hold 4 seconds. The lantern
LED will fade on or off to confi rm your
setting change.
CHECKING BATTERY STATE OF CHARGE (SOC)
BATTERY CHARGING
MAINTENANCE
SPECIFICATIONS FLASH CODES
RECYCLING
If the battery is ≤14%, low voltage disconnect (LVD) disables the LED and attempts to
charge the battery to a sustainable SOC. The LED is re-enabled once SOC is >75%.
810
or
Good battery
SOC >70%
Charge battery
SOC 14 - 70%
Low battery
SOC ≤14%, LVD Active
AUTOMATIC LIGHT CONTROL
During periods of sustained poor solar charging, Automatic Light Control (ALC) may
decrease LED intensity based on battery SOC and recent charging trends. When
solar charging returns to a sustainable level, ALC increases intensity back to the user
setting. ALC may be disabled to keep the lantern at a constant intensity.
Enable ALC: 801Disable ALC: 800
In “on” mode, the OL2A LED turns on at night and off during the day. The lantern
charges in sunlight, but the LED remains off when in “off ” mode. When turned on again,
the lantern activates at its last programmed settings (1 minute preview for daytime
activations).
Option 1: Switched Models
Set the switch to on or off
position
Option 2 : IR Programmer
Using the IR programmer, enter:
The batteries are best charged inside the lantern. The OL2A can recharge 0 V or 0%
SOC batteries back to 100% SOC:
C
AUTION
C
AUTION
The OL2A comes with 3x AA industrial-grade, high-temperature NiMH batteries. The
OL2A will only operate with all 3x batteries installed correctly. The lantern remembers
its settings even when the batteries are removed.
Other rechargeable AA NiMH batteries will not void your warranty. However,
shock, vibration, temperature and optical performance may be limited.
To install batteries:
1. Install batteries noting their polarity.
2. Apply a thin coat of silicone lubricant to the large sealing
o-ring.
3. Align top cover and assembly components; secure with
the provided screws. Do not over tighten!
BATTERY INSTALLATION
Do not use a battery charger with >370 mA charge rate. High charge rates will
over heat the batteries and cause internal damage.
Take care when charging using a lamp. Provide air circulation or a fan so that
lantern and batteries do not exceed max. temperature.
C
AUTION
Summer sunlight 8-12 hours
Winter sunlight 18-36 hours
60 W incandescent lamp 15-36 hours
Although the OL2A is maintenance-free, performance gains can be made. Clean with
water and a soft sponge or cloth. A mild non-abrasive cleanser can be used for more
stubborn residue. Clean more frequently during drier months as dust accumulates more
quickly. Check the exterior and o-rings for cracks and missing or broken hardware.
• If a lantern detects continuous dark for 24 hrs., like when it’s inside packaging for
shipping or storage purposes, it will disable the LED. Upon sensing light, it will
enable the LED and continue normal operation.
• Check the battery state of charge every 1 - 2 months and charge if required.
• High-grade NiMH batteries shipped with the OL2A can be stored without any
charging for up to 12 months with no battery damage.
STORAGE
TROUBLESHOOTING
Turn the lantern off to store. In switched models, set the switch to the “off ” position. To
turn off using the IR programmer, press and hold for 4 seconds.
TURNING ON/OFF
LED is off
during the
night
Batteries are very low and
lantern cannot turn on
Charge the lantern or replace the batteries.
Batteries are low and LVD is
active
Confi rm with code 810 using IR programmer. Charge lantern or
replace batteries. Decrease eff . intensity to a sustainable level.
Switch is off Switch to on.
Night not yet detected Wait for the lantern to detect 2 min. of consistent “dark.”
Nearby light source is
illuminating the lantern
Move away from light source, turn off unneeded light or shield
lanterns.
Solar panel is not charging the
battery well during the day
Under bright sunlight, enter code 815 using the IR programmer:
1x fl ash= too low for charging, 2x fl ashes = solar panel is fi ne
No response
to IR
programmer
Batteries are very low and
lantern cannot turn on
Charge the lantern or replace the batteries.
Sunlight is obscuring IR signal Move the IR programmer closer to the lantern.
Moisture
inside
Condensation Ensure the vent on the bottom cover is not dirty or obstructed.
Seal failure Ensure bottom cover o-ring is dry (no water), lubricated and
fully seated; o-ring is not pinched; all screws are fully installed.
Visit www.fl ashtechnology.com for complete specifi cations.
Maximum eff ective intensity varies by fl ash code and color. “FL” is the fl ash duration (sec) and “EC” is an eclipse
(sec). Intensities are IALA values (10th percentile) over a 360° horizontal measurement.
This product may contain substances that could be harmful to the environment or
human health if improperly handled at the product’s end of life. Check your local
municipality for electronics recyclers.
The batteries are rechargeable nickel-metal hydride (NiMH). Consult your local
laws for information on recycling.
This product complies with the European Union’s requirements according to
Directive 2002/96/EC on waste electrical and electronic equipment (WEEE).
This product is covered by the Flash Technology warranty. Failure to comply with the
use, storage, maintenance or installation instructions detailed in this manual could void
the warranty. Changes or modifi cations not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
Email: customerservice@fl ashtechnology.com
Toll Free: 1.800.821.5825
Fax: 1.615.261.2600
Web: fl ashtechnology.com/obstruction
WARRANTY
Code
Cycle
Maximum Effective Intensity (cd)
Temperature -40 to 176 °F (-40 to 80 °C) Light Source High-power LED, >100,000 hrs. lifetime
Intensity See Flash Code table Flash See Flash Code table
Divergence >8 ° FWHM Vertical Divergence Chromaticity Blue, red, white, yellow, and green
Battery 3x AA high-temperature nickel-metal
hydride (NiMH), 1.2 V nominal each.
-40 to 185 °F (-40 to 85 °C) ambient
Immersion IP68, 3 ft. (1m) for 72 hrs.; EN 60529
MIL-STD-202G immersion & damp heat
cycling, MIL-STD-810G rain & salt fog
Regulatory RoHS Restriction of Hazardous Substances Directive 2002/95/EC (RoHS)
CE EN 60945, EN 61000-6-1, EN 61000-6-2, EN 61000-6-3
FCC This device complies with Part 15 of the FCC Rules (see 15.109)
ICES This Class [B] digital apparatus complies with Canadian ICES-003. Cet appareil
numérique de la classe [B] est conforme à la norme NMB- 003 du Canada.
Patents US and International patents apply
A commercial charger designed for 1.2 V AA batteries can also be used.
ON
OFF
2-Hole Flange Mount
0.8 lb (0.35 kg)
Pole Mount
0.9 lb (0.40 kg)
4.9 - 5.0 in
124 - 128 mm
154 mm
6.1 in
4.6 in
117 mm
2.2 in
56 mm
1.6 in
40 mm
3.0 in
70 mm
3.8 in
97 mm
2.2 in
56 mm
0.8 in
20 mm
0.27 in
6.8 mm
With sleeve:
1.9 in (48 mm) pole ID
Without sleeve:
2.4 in (61 mm) pole ID
Overtop mount:
2.8 in (71 mm) pole OD
70951 Rev D OL2A Manual