© 2017 FINE ITE, INC. A RIGHTS RESERVED. Form 98303 V3. 02/17
Protected by one or more US Patents: 8915613; D702,391; D702,390; D700,732; D727,554 S; D727,550 S, D727,551 S
Note: All power connections to be installed to
local/national codes by a Certified Electrician.
Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • (510) 441-1100 • Fax: (510) 441-1510 • www.finelite.com
3
HP-2 Recessed 1" T-Bar to Spackle Flange Installation Instructions
T-Bar Bracket (provided)
Tie-wire
(by others)
#8-18 x 1/4" Screws
(4) (provided)
#6-20 x 1/2" Self
Drilling Screws (4)
(provided)
Wall
Ceiling
Ceiling Joiner
Corner Joiner
Diffuser
Diffuser
Replace diffusers and turn power on to luminaires.
Wires
Conduit Plate
Jam Nut
Conduit
Run power cables through conduit plate and jam nut. Make electrical
connections. Secure conduit onto conduit plate with jam nut, and
reinstall conduit plate carefully not to damage any wiring.
Remove conduit plate from ceiling joiner luminaire.
Step 12
Step 13 Step 15
Step 11
Install T-Bar brackets (provided) onto ceiling joiner with #8-18 x 1/4" screws (provided). Secure
luminaire to T-Bar with #6-20 x 1/2" self drilling screw (provided). Secure luminaire to structure
using tie-wire (by others), as per code.
#8-18 x 1/4" Screws
(4) (provided)
#6-20 x 1/2" Self
Drilling Screws (4)
(provided)
Wires
Splice Box Door
Jam Nut
Conduit
OPTIONAL SPLICE BOX
Run power cable through knock-out. Make electrical
connection. Secure conduit on to splice box with jam
nut and close splice box door.
Open optional splice box door to access wiring.
OPTIONAL SPLICE BOX
Ceiling
Corner Joiner
Wall
Drywall screws
(by others)
“Mud Guard”
Cardboard Inserts
(provided)
Trowel
Step 14
Fasten corner joiner to wall with drywall screws (by others). Install “mud
guard” cardboard inserts (provided). Use spackle to cover up the flanges.
Once spackling is complete, remove the mud guards.