Fife CDP-01 Manual de usuario

DATE 02-28-97 CDP-01 Fig. Sheet 1-749
CDP-01
Additional Instruction Manual
For Moving Sensor Center Guide

DATE 02-28-97 CDP-01 Fig. Sheet 1-749

DATE 02-28-97 CDP-01 Fig. Sheet 1-749
NOTE
These additional instructions explain the special features of the system delivered to the customer. They
are intended for being used in conjunction with the CDP-01 Reference Manual. The CDP-01 Reference
Manual applies except as noted to the contrary in these instructions.
Copyright:
All rights reserved. Any reproduction of this Additional Instruction Manual, in any form, in whole or in part,
requires the prior written consent of FIFE.
The information given in this Additional Instruction Manual is subject to change without notice.
We have compiled this Additional Instruction Manual with the greatest possible care and attention:
however, the possibility of error can not be completely excluded. FIFE accepts no legal liability for
incorrect information given and the consequences arising therefrom.
Copyright 1996 FIFE Corporation, P.O. Box 26508, Oklahoma City, OK 73126, U.S.A.
FIFE GmbH,Postfach 1240, D-65762 Kelkheim/Ts., Germany

DATE 02-28-97 CDP-01 Fig. Sheet 1-749

CONTENTS I
DATE 02-28-97 CDP-01 Fig. Sheet 1-749
Table of contents
GENERAL 1
SOFTWARE PART NUMBERS .............................................................................................1-1
CONNECTING THE SYSTEM COMPONENTS.....................................................................1-2
APPLICATION DESCRIPTION..............................................................................................1-2
OVERVIEW OF FUNCTION 2
OPERATOR CONTROL OPTIONS .......................................................................................2-1
SPECIAL FEATURES OF EXTERNAL CONTROL................................................................2-1
INPUT MATRIX - EXTERNAL CONTROL.............................................................................2-2
EXPLANATORY NOTES ON THE MODES...........................................................................2-3
SENSOR SELECTION - SENSOR INDICATOR....................................................................2-8
TROUBLESHOOTING 3
FAULT DIAGNOSIS - FAULT RECTIFICATION....................................................................3-1

DATE 02-28-97 CDP-01 Fig. Sheet 1-749

SUPPLEMENTARY OPERATING MANUAL 1
1-1
DATE 02-28-97 CDP-01 Fig. Sheet 1-749
GENERAL
Software part numbers
The specific functions of this application are pre-set by Matrix Setup and State Machine.
The software part numbers are indicated on a label on the side of the CDP-01 housing. They include the
Matrix Setup No. ( MS ), the State Machine No. ( SM ) and the firmware version ( Dx ).
The software part numbers differ depending on the type of the application (electrical or hydraulic control of
the sensor positioner and/or the guide):
CDP version: CDP-01-MM D1:565023-02x MS: 581033.02x Please quote these details
D2:565024.02x SM: 581034.02x when making inquiries
D3: FIFE
CDP version: CDP-01-MH D1:565023-02x MS: 581035.02x
D2:565024.02x SM: 581036.02x
D3: FIFE
CDP version: CDP-01-MHH D1:565023-02x MS: 581037.02x
D2:565024.02x SM: 581038.02x
D3:565024.02x FIFE
Note: for these applications, signal amplifiers with firmware version
≥
2.0 must be used.

SUPPLEMENTARY OPERATING MANUAL 1
1-2
DATE 02-28-97 CDP-01 Fig. Sheet 1-749
Connecting the system components
The system components must be connected in accordance with the system diagram contained in the
documentation.
Description of the application
The sensors are positioned manually (edge guiding configuration) or automatically (center guiding
configuration) over the edge of the web. The web is adjusted to the position of the sensor via the guide.
The material web can be shifted in edge and center guiding configurations.
Scope of application: edge and center guiding configuration systems with moving sensors, fixed web
center point and internal or external control.

SUPPLEMENTARY OPERATING MANUAL 2
2-1
DATE 02-28-97 CDP-01 Fig. Sheet 1-749
OVERVIEW OF FUNCTION
Operator control options
The CDP-01 signal amplifier can be operated from the control panel (internal control panel) or via the
parallel port with a remote control panel or a programmable logic controller (PLC, external operation).
The following symbols are used for the various operator controls in the remainder of this description:
Internal operation
External operation
Special features of external control
The mode keys (Automatic, Servo-Center, Manual) on the
internal control panel are disabled.
Changing mode via external control is not possible when
the SETUP function is activated on the internal control
panel.
In the ‘Manual - Guide’ and ‘Manual - Sensor Positioner’
modes, the drive selector key is disabled.
When the remote control panel is disconnected the last
mode selected is retained until other settings are made on
the internal control panel.

SUPPLEMENTARY OPERATING MANUAL 2
2-2
DATE 02-28-97 CDP-01 Fig. Sheet 1-749
Input Matrix - external control
CDP-01 inputs
Modes I0 I1 I2 I3 I4 I5
Lockout H - - - - -
Manual - Guide - H H L - -
Manual - Sensor positioner - H L H - -
Automatic - L L H - -
Servo-center - L H L - -
Jog Left - Guide - H H L H L
Jog Right - Guide - H H L L H
Jog Left - Sensor positioner - H L H H L
Jog Right - Sensor positioner - H L H L H
Automatic - Left web displacement - L L H H L
Automatic - Right web displacement - L L H L H
L = Low level
H = High level