Fife CDP-01 Manual de usuario

02-04-03 CDP-01 Figure Sheet 1-856-A
CDP-01
Additional Instruction Manual
For Recoiler Application With Staggerwind
Using SE-34 Sensor And SBPC-2X (MS:100279)

02-04-03 CDP-01 Figure Sheet 1-856-A

SUPPLEMENTARY OPERATING MANUAL i
02-04-03 CDP-01 Figure Sheet 1-856-A
COPYRIGHT
NOTE
These additional instructions explain the special features of the system delivered to the customer. They
are intended for being used in conjunction with the CDP-01 Reference Manual. The CDP-01 Reference
Manual applies except as noted to the contrary in these instructions.
Copyright:
All rights reserved. Any reproduction of this Additional Instruction Manual, in any form, in whole or in part,
requires the prior written consent of FIFE.
The information given in this Additional Instruction Manual is subject to change without notice.
We have compiled this Additional Instruction Manual with the greatest possible care and attention:
however, the possibility of error can not be completely excluded. FIFE accepts no legal liability for
incorrect information given and the consequences arising therefrom.
Copyright 2002 FIFE Corporation, P.O. Box 26508, Oklahoma City, OK 73126, U.S.A.
FIFE GmbH,Postfach 1240, D-65762 Kelkheim/Ts., Germany

02-04-03 CDP-01 Figure Sheet 1-856-A

SUPPLEMENTARY OPERATING MANUAL iii
02-04-03 CDP-01 Figure Sheet 1-856-A
TABLE OF CONTENTS
GENERAL INTRODUCTION 1
APPLICATION DESCRIPTION..............................................................................................1-1
SOFTWARE PART NUMBERS.............................................................................................1-1
CONNECTING THE SYSTEM COMPONENTS....................................................................1-1
OVERVIEW OF FUNCTION 2
OPERATOR CONTROL OPTIONS.......................................................................................2-1
SPECIAL FEATURES OF EXTERNAL CONTROL ..............................................................2-1
EXTERNAL CONTROL..........................................................................................................2-2
CONTROL MATRIX...............................................................................................................2-2
CDP-01 DATA........................................................................................................................2-3
EXPLANATION OF THE OPERATING MODES........................................................ 2-4 to 2-5
EXPLANATION OF THE SENSOR MODES.........................................................................2-5
START UP / POSITION TRANSDUCER CALIBRATION.....................................................2-6
START UP / SENSOR BANDWIDTH TO MANDREL RATIO CALIBRATION.....................2-7
START UP / MANDREL DRIVE POLARITY .........................................................................2-8
TROUBLESHOOTING 3
FAULT DIAGNOSIS - FAULT RECTIFICATION...................................................................3-1

02-04-03 CDP-01 Figure Sheet 1-856-A

SUPPLEMENTARY OPERATING MANUAL 1
1-1
02-04-03 CDP-01 Figure Sheet 1-856-A
GENERAL INTRODUCTION
Application Description
Application is a Recoiler using the SE-34 Sensor. A linear analog position feedback is used on
the mandrel. The mandrel to sensor bandwidth ratio is programmable. An OSC-20 is used to
provide oscillation of the web within the proportional band of the sensor. External control is
required via SBPC. When placed in automatic mode, the sensor output signal and the mandrel
position are recorded. The sensor continues to monitor the web edge and the mandrel then
follows the sensor output signal.
A CDP-01-H12 or CDP-01-M12 with FifeNet firmware is required for this application.
Software Part Numbers
The software part numbers are located on the side of the CDP-01 housing. They include the
Matrix Setup no. (MS), State Machine no. (SM) and firmware version ( Dx ).
CDP version: CDP-01-H12 D1:5650xx-02x MS: 100279.02x
or CDP-01-M12 D2:5650xx-02x SM: 100280.02x
D3:5650xx-02x FIFE USA
Connecting the System Components
The system components are to be connected according to the Cable Connection Diagram
contained in the documentation.

02-04-03 CDP-01 Figure Sheet 1-856-A

SUPPLEMENTARY OPERATING MANUAL 2
2-1
02-04-03 CDP-01 Figure Sheet 1-856-A
OVERVIEW OF FUNCTION
Operator Control Options
The CDP-01 signal amplifier can be operated by way of the CDP-01 control panel (internal
operation) for setup purposes only. For normal operation, control through the SBPC must be
used (external control). Control is to be supplied from a remote control panel or programmable
logic controller. The parallel port (X7) is disabled.
The symbols below are used for the various operator control options in the following:
Internal operation
External operation
Special Features of External Control
When the operation modes are being controlled via
external control, the Automatic, Servo-Center, Manual keys
of the CDP-01 control panel are disabled.
If the cable to the serial port ( -X8 ) of the CDP-01 is
disconnected, the CDP-01 will lock up.

SUPPLEMENTARY OPERATING MANUAL 2
2-2
02-04-03 CDP-01 Figure Sheet 1-856-A
External Control
CUSTOMER NETWORK TO FIFE NETWORK
Scheduled
Data Word1Data
Type2Variable Description
0 WORD Control
Matrix Used to control the CDP-01 in accordance with
the control matrix.
1 WORD Reserved
These values are reserved for state machine
communication.
2 WORD Reserved
3 WORD Reserved
4 WORD Reserved
5 WORD Reserved
6 WORD4 Line Speed Used to Input Line Speed.
1 All registers are 16-bit.
2 Data Types:
INT 16-bit signed value in the range of –32,768 to +32,767.
WORD 16-bit unsigned value in the range of 0 to 65,535.
3 Commands to the CDP-01.
4 Line Speed Input is a 10 bit WORD and has a range of 0 to 1,023.
Control Matrix
COMMAND VIA NETWORK HEX
AUTOMATIC W/OSCILLATION OFF 02
AUTOMATIC W/OSCILLATION ON 03
SEEK OVERIDE W/OSCILLATION OFF 0A
SEEK OVERIDE W/OSCILLATION ON 0B
MANUAL 06
SERVO-CENTER 04
JOG LEFT 16
JOG RIGHT 26
RGPC SHIFT LEFT 1*
RGPC SHIFT RIGHT 2*
RGPC RESET 3*
* RGPC works with the first four modes listed (Automatic and Seek Overide). The least significant
digit (far right) will need to remain constant. (i.e. RGPC shift right when in Auto with oscillation on
would be a hex value of ‘23’. RGPC shift left in Seek Overide with oscillation off would be a hex
value of ‘1A’.)
NOTE: If the Control Matrix is set to ‘00’, the CDP-01 will change to Manual mode.