2
mounting holes. 20 mm cable entries are provided on all
sides and in the base. To maintain the integrity of the
weather seal, the cable entry must be via a suitable
sealed gland.
L wer part f h using
In order to use the cable entries please remove the
appropriate opening in the lower part of the housing
using a screwdriver. The screwdriver is put into the slot
provided and then given a firm jolt. The pre-punched
plastic plate in the lower part of the housing will then
break off neatly. An appropriate cable entry can then be
mounted or you can guide the cable directly through the
new opening created.
Recycling
The device may be completely recycled as electronic
waste. When the device is disassembled, plastics,
metals and electronics are to be disposed of separately.
Installati n
The sounder or combined sounder strobe units can be
affixed to most surfaces using screws through the holes
of the bottom part.
Supply input
Ensure that the supply is correct for the voltage rating of
the sounder or combined sounder strobe being installed.
Ensure that the supply is OFF before making any con-
nection and wire only in accordance with the terminal
label detail.
S und selecti n
Ensure the supply is OFF before proceeding. All dc and
ac units have selectable alarm sounds (see table below
for details) and are selectable by means of the 5 way DIL
switches SW1 for the first stage and SW2 for the second
stage. For dc units the second sound is made available
upon the application of a third wire connected to terminal
TB 1/3 as shown in Fig. 1 while still connected to termi-
nal TB 1/2. Alternatively first and second stage sound
signals can be generated by supply reversal at terminals
TB1/3 and TB1/4 , see Fig. 2. For ac units the second
stage sound is available upon the application of a third
wire L to TB3, see Fig.3.
M unting
The lower part of housing should be mounted to a suita-
ble surface or to a standard wiring box using any of the
The device complies with the requirements of the
new EMC-directive 2004/108/EC and the low voltage
directive 2006/95/EC.
The conformity with the above directives is confirmed
by the CE sign.
EMC-Directive
Housing Polycarbonate
Colour Red, similar to RAL 2002
Insulation class II
Protection degree IP 65 acc. to IEC 60529
Cable gland
intended for M20 x 1.5 or Self-sealing grommet
Volume approx. 106 dB(A) (depending on signal tone)
Signals
32 different signal tones (see diagrams), 2nd stage can be turned on externally
Temperature range
Operation
-25 C
to
+55 C
Storage
-40 C
to
+70 C
Weight 0.6 kg
Operating voltage
24 VDC, 115 VAC, 230 VAC
Connecting terminals Clamping capacity 2.5 mm2solid conductor / 1.5 mm2stranded conductor
Flash power 5 J
Cap colours red, yellow, green, blue, clear
Technical Data AXL04
Housing Polycarbonate
Colour Red, similar to RAL 2002
Insulation class II
Protection degree IP 65 acc. to IEC 60529
Cable gland intended for M20 x 1.5 or Self-sealing grommet
Volume approx. 106 dB(A) (depending on signal tone)
Signals 32 different signal tones (see diagrams), 2nd stage can be turned on externally
Temperature range
Operation -25 C to +55 C
Storage -40 C to +70 C
Weight 0.2 kg
Operating voltage 24 VDC, 115 VAC, 230 VAC
Connecting terminals Clamping capacity 2.5 mm2solid conductor / 1.5 mm2stranded conductor
Technical Data AX04