Sidus F1Q – free flight electronic timer
4/8
Programmer
The Programmer is needed to change the timing sequence and dethermalize the model. It
also allows to accurately adjust the servo(s) positioning and change other settings.
The possible options are displayed at the corners of a rectangle: a choice is selected by
pressing the key that corresponds to the same corner in the rectangle made up of the 4
keys named T1, T2, T3, T4 (see drawing).
A long (press and hold) or short (press and release) key pressure may be required
according to the following rule: choices displayed in upper case (e.g. READ,
UNLOCK,..) require a long pressure, choices displayed in lower case (e.g. Exit,
Servo,..) require a short pressure.
Every time the Programmer has to communicate with the Timer, make sure the
Timer is ON (if sleeping, just wake it up by shortly pressing the start switch) and
keep the Timer and the Programmer closer than 20 cm. with the IR sensors
mutually visible. In case of communication failure, the message “
ERROR
” is displayed.
Timing visualization
For each function the Programmer displays the programmed activation time of each
function:
Motor stop time and DT time are displayed explicitly:
All the displayed time values are absolute, i.e. referred to time zero.
The motor stop time is freely programmable between start and DT. All the other
functions are strictly sequential (FUNC1 > FUNC2 >,.., DT) and their activation time
is programmable in a range between the activation time of the previous and
following functions. Example: if FUNC1 = 11.8s and FUNC3 = 13.6s then FUNC2 can
range from 11.9s to 13.5s
Automatic switch off of the Programmer
The Programmer automatically goes to “sleep” to save power if inactive for about 120
seconds and wakes up by pressing any key. If the internal LiPo battery needs to be
recharged the message “
Battery low!
” is displayed.
READ
READREAD
READ R
R R
RDT
DTDT
DT
UNLOCK
UNLOCKUNLOCK
UNLOCK
SET
SETSET
SET
FUNC4 t=16.8s
FUNC4 t=16.8sFUNC4 t=16.8s
FUNC4 t=16.8s
Exit
ExitExit
Exit
function nr.
FUNC4 is activated 16.8s after start
MOTOR
MOTOR MOTOR
MOTOR t=14.9s
t=14.9s t=14.9s
t=14.9s
Exit
ExitExit
Exit
DT
DT DT
DT t=180s
t=180s t=180s
t=180s
Exit
ExitExit
Exit