Fastback Liberator-V100 Manual de usuario

Liberator-V100 / V1000 User Manual Rev 03v12p4
Page 1 FBN Doc #: FBN-0098_03v12p4
Fastback Networks - 2460 N First St., Suite 200, San Jose, CA 95131 U.S.A.
Sub10 Systems Ltd. - Ash House, Canal Way, Kingsteignton, Newton Abbot, Devon, TQ12 3RZ, UK
Liberator-V100 / V1000
User Manual
Revision 03v12p4
Firmware –v02.01.03.12

Page 2 FBN Doc #: FBN-0098_03v12p4
Document Type
User Manual
Project
Liberator-V100 / V1000
Date
20 July 2015
Title
V100 / V1000 Installation & User Manual
Document Number
FBN-0098_03v12p4
Version
Date
Description
03v01
17 Dec 2014
Release 02.01.03.01
03v12
20 July 2015
Release 02.01.03.12

Liberator-V100 / V1000 User Manual Rev 03v12p4
Page 3 FBN Doc #: FBN-0098_03v12p4
1 INTRODUCTION ...............................................................................................................................4
1.1 Revision...................................................................................................................................................4
1.2 Intended Users & Software Version .....................................................................................................4
1.3 Safety Information..................................................................................................................................4
1.4 Warranty..................................................................................................................................................4
1.5 Copyright / Disclaimer ...........................................................................................................................4
2 SYSTEM OVERVIEW..........................................................................................................................5
2.1 Top Level Description............................................................................................................................5
2.2 Ethernet switch.......................................................................................................................................6
2.3 Package contents...................................................................................................................................7
2.4 Accessories and Spares (available to order as additional parts) ...................................................10
4 Installation ....................................................................................................................................11
4.1 Terminal installation ............................................................................................................................11
4.2 Grounding .............................................................................................................................................11
4.3 Alignment Procedure...........................................................................................................................12
4.4 Factory-Defaulting a Terminal.............................................................................................................14
5. Web Management Interface .........................................................................................................15
5.1 Login Page ............................................................................................................................................15
5.2 Home Page............................................................................................................................................16
5.3 Operation...............................................................................................................................................17
5.4 Administration......................................................................................................................................18
5.5 Maintenance..........................................................................................................................................23
5.6 Logout ...................................................................................................................................................25
Figure 34 - User Account Logout Page...................................................................................................25
A TECHNICAL INFORMATION ............................................................................................................26
A.1 Specifications ......................................................................................................................................26
B REGULATORY INFORMATION .........................................................................................................28
B.1.1 FCC statement ..................................................................................................................................28
B.1.2 ETSI Conformity................................................................................................................................29
C CONTACTS.................................................................................................................................30
C.1 Technical assistance...........................................................................................................................30
C.2 Sales & General Product Information................................................................................................30

Page 4 FBN Doc #: FBN-0098_03v12p4
1 INTRODUCTION
1.1 Revision
Fastback Networks & Sub10 Systems reserve the right to revise this documentation periodically without any
obligation to provide notification of such revision or changes.
1.2 Intended Users & Software Version
This manual is intended for all installation and service personnel who are involved in the planning, installation,
operation and maintenance of the Liberator-V100 and V1000 equipment.
This Manual refers to Liberator-V100 running Software Version 01.01.01.17, and Liberator-V1000 running Software
Version 02.01.03.12. Please ensure that the software on the radio terminals is the latest version on the Fastback
Networks website: http://www.fastbacknetworks.com
1.3 Safety Information
1.3.1 Grounding
The V1000 radio terminal (outdoor unit) must be properly grounded to protect against lightning strikes. It is the
user’s responsibility to ensure that the equipment is installed in accordance with national regulations:
USA: Articles 810 & 830 of the National Electric Code ANSI/NFPA No.70-1984
Other countries may require different regulations.
1.3.2 Power Supply
The Sub10 Systems PoE++ power injector should always be used to power the Liberator-V100 / V1000. The
installer must ensure that a mains voltage supply cable approved for the country of installation is used.
1.3.3 Maintenance and Servicing
•Always disconnect the primary power source before undertaking maintenance/repair of the radio
terminal (Outdoor Unit).
•At least once per year, each radio terminal (Outdoor Unit) must be inspected for signs of corrosion.
1.4 Warranty
Sub10 Systems warrants to the original end user (purchaser) that this product is free from any defects in
materials or workmanship for a period of up to 24 months (2 years) from the date of shipment to the end
user.
1.5 Copyright / Disclaimer
Copyright © 2014, 2015 by Fastback Networks / Sub10 Systems.

Liberator-V100 / V1000 User Manual Rev 03v12p4
Page 5 FBN Doc #: FBN-0098_03v12p4
2 SYSTEM OVERVIEW
2.1 Top Level Description
The Liberator-V100 and V1000 systems operate in the unlicensed 60 GHz
band between 57 GHz and 64 GHz. The antenna radome face measures
only 18cm x 18cm (7” x 7”), making it ideal for unobtrusive urban
deployments.
2.1.1 Benefits
•Network performance –Full-duplex data rate 100Mbps (V100), and up to 1Gbps (V1000).
•Licence-free operation –The system has been approved and can be operated in many countries without
needing an individual regulatory licence for each link.
•System administration –The user can manage the link either via the HTML user interface or by integrating it
into a network management tool via SNMP.
•Security –Data traffic is very secure due to signal absorption by atmospheric oxygen and the high
gain/narrow beamwidth antennas.
2.1.2 Applications
•LAN extension
•Redundant access
•Campus connectivity
•Disaster recovery
•Wireless backhaul
Figure 1 - V1000 radio terminal

Page 6 FBN Doc #: FBN-0098_03v12p4
2.2 Ethernet switch
Each radio terminal includes an Ethernet switch.
Figure 2 - Network layers of the V100 / V1000 system

Liberator-V100 / V1000 User Manual Rev 03v12p4
Page 7 FBN Doc #: FBN-0098_03v12p4
2.3 Package contents
A complete link is packed in one box, which contains:
•Terminal A
•Terminal B
•Adjustable Alignment Brackets
•Mast brackets
•Sealed Ethernet connectors
Figure 3 –Contents of V100 / V1000 Link Kit (EU mains plug version), showing parts for one end of the link
NOTE: - In the USA, the PoE power supply may be ordered separately from the rest of the link kit. Please check
the ordering guide for more information.
2.3.1 Terminals
Each terminal is connected to the network via an Ethernet cable with RJ-45 connectors. Power is supplied to the
terminal through the Ethernet cable.
•Ice bridges /Sun-shields
•PoE++ mains power injectors and leads
•Fixing and accessory kit
•Quick Start Guide
Figure 4 - V100 / V1000 terminal

Page 8 FBN Doc #: FBN-0098_03v12p4
2.3.2 Alignment Bracket
The alignment bracket is very simple to use and has locking nuts.
2.3.3 PoE++ Injector
The Power-over-Ethernet power (PoE) supply conforms to “PoE++” specifications. It is recommended that the
Sub10 Systems PoE++ power injector should always be used to power the Liberator-V100 / V1000. The installer
must use a mains voltage supply cable approved for the country of installation.
Figure 5 - Alignment bracket
Figure 6 (a) SL Power PENT 1040B PoE++ power injector and (b) PhiHong POE61W PoE++ power injector

Liberator-V100 / V1000 User Manual Rev 03v12p4
Page 9 FBN Doc #: FBN-0098_03v12p4
2.3.4 Mast Bracket
The mast bracket is used to mount the bracket onto a mast from 50 mm to 115 mm diameter.
2.3.5 Ice Bridge/Sun-Shield
The ice bridge protects the terminal against rain, snow and ice.
2.3.6 RJ45 Seal Kit
The RJ45 seal kit connects the Ethernet tail from the ODU to a CAT 5e drop cable, and includes a rain hood.
Figure 7 - Mast bracket
Figure 8 - Ice bridge mounted on V1000
Figure 9(a) - RJ45 Seal kit Figure 9(b) - Rain cover for RJ45 seal kit

Page 10 FBN Doc #: FBN-0098_03v12p4
2.4 Accessories and Spares (available to order as additional parts)
2.4.1 Optical Alignment Scope
The optical scope screws onto the back of the ODU.
2.4.2 Surge Arrestor
The surge arrestor is placed between the ODU and the Ethernet cable
connecting to the PoE.
2.4.3 Wall-mount bracket
The wall-mount bracket allows the alignment bracket to be mounted directly onto a flat surface.
Figure 12 - Wall-mount plate (bracket)
Figure 10 - Optical alignment scope
Figure 11 - Surge arrestor
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Manuales populares de Enrutador de red de otras marcas

NETGEAR
NETGEAR FS526T - Switch Manual de usuario

Korenix
Korenix JetNet 5710G Series Manual de usuario

Automated Logic
Automated Logic ZN551 Manual del propietario

Cisco
Cisco ASR 1000 Series Manual del operador

EnGenius
EnGenius ESR-9710 Manual de usuario

Cisco
Cisco 805 Series Instrucciones de funcionamiento y seguridad