4 – To test motor Z click the associated buttons for Z axis ( up button labeled (Z+) and
down button labeled (Z-) ).
When up button is Pressed
1 – Green LED labeled ENA is turned on.
2 – Yellow LED labeled DIR is turned on.
3 – Red LED labeled CLK is flicked.
When down button is pressed
1 – Green LED labeled ENA is turned on.
2 – Yellow LED labeled DIR is turned off.
3 – Red LED labeled CLK is flicked.
The activated outputs also are highlighted on main window.
5 – To test motor V click the associated buttons for V axis ( up button labeled (V+) and
down button labeled (V-) ).
When up button is Pressed
1 – Green LED labeled ENA is turned on.
2 – Yellow LED labeled DIR is turned on.
3 – Red LED labeled CLK is flicked.
When down button is pressed
1 – Green LED labeled ENA is turned on.
2 – Yellow LED labeled DIR is turned off.
3 – Red LED labeled CLK is flicked.
The activated outputs also are highlighted on main window.
6 – To test the input just apply the input and the state of inputs will be updated continuously
every 100 msec.
The activated inputs appear as highlighted boxes labeled (O ), and the inactivated inputs
appear as dimmed boxes labeled (OFF).
Note
1 - All inputs are active low. I.e. to active an input apply ground (GND) to it .
2 – The status of input LED is opposite to the input state. I.e if the input is activated
(connected to ground), then the LED is turned off and vice versa.