1. Beschreibung···································································································· 3
2. Lieferumfang····································································································· 3
3. Aufbau, Anschlüsse & LED‘s··············································································4-5
3.1 Aufbau························································································································ 4
3.2 Anschlüsse & LED‘s····································································································4-5
4. Hardware Installation··························································································· 6
5. Konfiguration des Geräteserver ············································································· 7
6. VCOM Admin Utility ······················································································· 8-12
7. DIP-Schalter Einstellungen ·················································································13
8. Reinigung········································································································14
9. Technische Daten ·····························································································14
10. Technische Zeichnung ·······················································································14
Inhaltsverzeichnis
Index
© Copyright 2021 by EXSYS Vertriebs GmbH. All Rights Reserved
1. Description ······································································································15
2. Extent of Delivery······························································································15
3. Layout, Connections & LED’s········································································· 16-17
3.1 Layout ······················································································································ 16
3.2 Connections & LED‘s······························································································· 16-17
4. Hardware Installation ·························································································18
5. Configuration of the Device Server ·······································································19
6. VCOM Admin Utility ····················································································· 20-24
7. DIP-Switch Settings···························································································25
8. Cleaning··········································································································26
9. Technical Information·························································································26
10. Technical Drawing·····························································································26

3
EX-6131PoE Deutsch
Der EX-6131PoE ist ein Serieller Multiprotokoll RS-232/422/485 Geräteserver. Welcher für den
Anschluss von zwei seriellen RS-232/422/485 Geräten, einschließlich POS, Barcode-Lesegeräten,
Sensoren, Messgeräten, CNC-Steuerungen und SPS an ein IP-basiertes Ethernet-Netzwerk aus-
gelegt ist. Die seriellen Geräte werden somit an das Netzwerk angeschlossen und sind somit im
Internet zur gemeinsamen Nutzung verfügbar, wobei die Fernkonfiguration über die umfangreichen
Netzwerkprotokolle wie TCP-Server, TCP-Client, UDP, VCOM, serielles Telnet, RFC2217, Remote
-Pair-Master-Slave, Modbus RTU erfolgt. Um abwärtskompatibel mit dem seriellen Legacy-Gerät
zu sein, auf dem die vorhandene COM-Port-Anwendungssoftware läuft, bietet der EX-6131PoE
einen virtuellen COM-Port-Umleitungstreiber (VCOM), der Ihre serielle Anwendung perfekt mig-
riert, ohne die Software zu modifizieren. Darüber hinaus können serielle Geräte mit dem Remote-
Pair-Master-Slave-Modus über den Peer-to-Peer-Modus miteinander kommunizieren, ohne dass
ein zwischengeschalteter PC oder Konvertierungssoftware erforderlich ist.
Merkmale:
• 1x RS-232 Port & 1x RS-422/485 Port über RJ45 Ethernet 10/100Mbps
• Bis 921.6 Kbps Baud Rate
• Serielle Modi: RS-232, RS-422, RS-485 2-Draht & 4-Draht
• Netzwerk Protokolle: TCP Server, TCP Client, UDP, VCOM, Serial Telnet, RFC2217, Remo-
te-Pair-Master-Slave, Modbus Server, Modbus Client und SNMP
• Konfiguration: Windows-basiertes VCOM-Administrator-Dienstprogramm und Web-Browser
• Unterstützt 15KV ESD-Schutz für alle serielle Signale
• Unterstützt 5V über seriellen Anschluss
• IEEE802.3af PoE-PD: Kann über das Ethernet-Kabel mit Strom versorgt werden
• Zertifiziert für
Bevor Sie den EX-6131PoE in Ihr Netzwerk einbinden, überprüfen Sie bitte zuerst den Inhalt der
Lieferung:
• EX-6131PoE
• Netzteil (5V/4A)
• DIN-Rail Kit (EX-6096)
• Anleitung
• Treiber CD
1. Beschreibung
2. Lieferumfang
© Copyright 2021 by EXSYS Vertriebs GmbH. All Rights Reserved

4
Deutsch EX-6131PoE
3.1 Aufbau
3. Aufbau, Anschlüsse & LED‘s
© Copyright 2021 by EXSYS Vertriebs GmbH. All Rights Reserved
3.2 Anschlüsse & LED‘s
Status LED
1x Seriell RS-232 &
1x Seriell RS-422/485 RJ45 Anschluss
5V DC Anschluss für
beiliegendes Netzteil
Power/ACT LED
PoE LED
TXD LED
RXD LED
Reset Schalter
RXD LED
TXD LED
Port 2 (RS422/485)
Port 1 (RS232)
Pin Beschreibung RS-232 Mode RS-422 & RS-485 4-Draht Modi RS-485 2-Draht Modi
10 +5V +5V +5V +5V
9
Port 2
-RX-DATA-
8-RX+ DATA+
7-TX-
6-TX+
5GND GND GND GND
4
Port 1
CTS --
3RTS --
2RXD --
1TXD --
10-Pin Terminal Block:

5
EX-6131PoE Deutsch
3. Aufbau, Anschlüsse & LED‘s
3.2 Anschlüsse & LED‘s
© Copyright 2021 by EXSYS Vertriebs GmbH. All Rights Reserved
LED‘s:
LED Name Farbe LED Funktion
Power/Act LED
(RJ45) Grün Ständig an: Am RJ45 liegt Strom an
Blinken: Datenübertragung über das Netzwerk
Aus: Am RJ45 liegt kein Strom an
PoE LED
(RJ45) Orange
Ständig an: Entnahme des Stroms aus dem LAN-Kabel
(nur PoE Modell)
Off: PoE Strom wird nicht entnommen
Status LED
Grün
Blinken: Das Gerät ist eingeschaltet
(25-30 Sekunden werden ca. benötigt)
Aus: Das Gerät ist ausgeschaltet
TXD LED
(oben) Grün Blinken: Die serielle Schnittstelle sendet Daten
Aus: Die serielle Schnittstelle sendet keine Daten
RXD LED
(unten) Grün Blinken: Die serielle Schnittstelle empfängt Daten
Aus: Die serielle Schnittstelle empfängt keine Daten
RJ45 Anschluss:
RJ45 Anschluss
Pin Signal Pin Signal Pin Signal
1BI_DA+ 4BI_DC+ 7BI_DD+
2BI_DA- 5BI_DC- 8BI_DD-
3BI_DB+ 6BI_DB-

6
Deutsch EX-6131PoE
© Copyright 2021 by EXSYS Vertriebs GmbH. All Rights Reserved
Löcher für Wandmontage
Montage an Tragschiene
4. Hardware Installation
Beachten Sie bitte die folgenden Installationshinweise. Da es große Unterschiede zwischen PC‘s
gibt, können wir Ihnen nur eine generelle Anleitung zum Anschluss der EX-6131PoE geben. Bei
Unklarheiten halten Sie sich bitte an die Bedienungsanleitung Ihres Computersystems.
1. Installieren Sie die EX-6131PoE mit dem mitgelieferten DIN-Rail Kit auf einer Tragschiene
oder mit der Wandmontagehalterung an eine Wand.
2. Nun verwenden Sie ein Ethernet Kabel und verbinden Sie dieses mit dem RJ45 Anschluss der
EX-6131PoE und das andere Ende mit einem PC oder einem Switch.
3. Verbinden Sie nun Ihr serielles Endgerät mit dem 10-Pin Terminal Block der EX-6131PoE.
4. Schließen Sie jetzt das im Lieferumfang enthaltene 5V Netzteil an die dafür vorhergesehene 5V
Buchse der EX-6131PoE an. Warten Sie etwa 25-30 Sekunden bis die Status LED anfängt zu
blinken. Sobald diese LED blinkt, ist das Gerät betriebsbereit.

7
EX-6131PoE Deutsch
© Copyright 2021 by EXSYS Vertriebs GmbH. All Rights Reserved
5. Konfiguration des Geräteserver
Werkseinstellung:
Der EX-6131PoE wird mit folgenden Werkseinstellungen ausgeliefert:
Login User Name: admin
Password: system
IP Address: DHCP (Automatisch zugewiesen)
Network Operation Mode: VCOM Mode
Serial Interface: Port 1: RS-232 / Port 2: RS-485 2-Draht
Falls Sie den EX-6131PoE auf „Werkseinstellung“ zurücksetzen möchten, dann drücken und hal-
ten Sie den Reset Schalter für ca. 3-5 Sekunden gedrückt. Die Status LED erlischt und fängt ein
paar Sekunden später wieder an zu blinken.
Bitte beachten Sie das die Einstellungen nach dem Reset nicht identisch sind mit den Werksein-
stellungen! Wenn Sie den EX-6131PoE auf „Werkseinstellung“ zurückgesetzt haben, werden Sie
folgende Einstellungen im Gerät haben:
Login User Name: admin
Password: system
IP Address: Statisch 192.168.2.1
Network Operation Mode: TCP Server Mode
Serial Interface: Port 1: RS-232 / Port 2: RS-422

8
Deutsch EX-6131PoE
© Copyright 2021 by EXSYS Vertriebs GmbH. All Rights Reserved
6. VCOM Admin Utility
Da der EX-6131PoE mit aktiviertem DHCP-Modus ausgeliefert wurde, ist eine IP-Adresse erforder-
lich, um ihn zu konfigurieren. Der EX-6131PoE erhält standardmäßig automatisch eine IP-Adresse
von einem DHCP-Server (z.B. Ihrem Router). Wenn er nicht mit einem DHCP-Server verbunden
ist, verwenden Sie die Standard-IP-Adresse: 192.168.2.1. Um die IP-Adresse zu ermitteln, müssen
Sie das mitgelieferte VCOM Admin Utility (vspsetup.exe) installieren. Das Installationsprogramm
befindet sich auf der im Lieferumfang enthaltenen Treiber-CD in folgendem Ordner.
Wichtig! Bitte führen Sie das Installationsprogramm mit Rechtsklick „Als Administrator ausführen“
aus!
1. Ermitteln Sie die IP-Adresse: Starten Sie das VCOM Admin Utility (klicken Sie mit Rechtsklick
auf dem Windows-Desktop auf die Verknüpfung VCOM Admin Utility und starten Sie dies mit „Als
Administrator ausführen“).
Klicken Sie auf Remote Device Management > ADD Device > Search
Nachdem der EX-6131PoE gefunden wurde, klicken Sie auf Cancel, um die Suche abzubrechen.
Klicken Sie auf OK, um den EX-6131PoE hinzuzufügen.

9
EX-6131PoE Deutsch
© Copyright 2021 by EXSYS Vertriebs GmbH. All Rights Reserved
6. VCOM Admin Utility
2. Zuordnung der COM-Ports: Um den virtuellen COM-Anschluss zu erstellen und dem seriellen
Gerät zuzuordnen, klicken Sie auf COM Mapping > Add COM > OK
Um die COM-Port-Nummer zu ändern, klicken Sie auf COM Mapping > Modify COM
Der COM3 & COM4 wurde nun hinzugefügt!

10
Deutsch EX-6131PoE
© Copyright 2021 by EXSYS Vertriebs GmbH. All Rights Reserved
6. VCOM Admin Utility
Überprüfen Sie bitte ob im Gerätemanager die COM-Port‘s hinzugefügt wurden! Es sollte nun
folgender Einträge im Gerätemanager sichtbar sein:
3. Ändern der Einstellungen der seriellen Schnittstelle: Wenn Sie die Einstellungen der seriel-
len Schnittstelle auf andere Werte als die Standardwerte ändern (z.B. Device Description, Pass-
word, ...), müssen Sie sich zuerst am Device Server anmelden (das Standardpasswort hierfür
"system").
Klicken Sie auf Remote Device Management > Login
Tabla de contenidos
Idiomas:
Otros manuales de Servidor de Exsys

Exsys
Exsys EX-61004 Manual de usuario

Exsys
Exsys EX-61001 Manual de usuario

Exsys
Exsys EX-6118 Manual de usuario

Exsys
Exsys EX-6122PoE Manual de usuario

Exsys
Exsys EX-6121PoE Manual de usuario

Exsys
Exsys EX-6112PoE Manual de usuario

Exsys
Exsys EX-6114 Manual de usuario

Exsys
Exsys EX-6118PoE Manual de usuario

Exsys
Exsys EX-61001 Manual de usuario

Exsys
Exsys EX-6121 Manual de usuario