Explorer Technology Group DLV50 Manual de usuario

Operator’s Manual
DLV5
0 Data L
Rev: 03
Date: 6/26/2012
DLV50 Firmware: Rev 000.009 and above
Winmeter 5.0 Software: Rev 1.0.0 and above
Operator’s Manual
0 Data L
ogging Voltmeter
ogging Voltmeter
Plus

able of Contents:
1.0 Overview
2.0 Menu System
2.1 Main Menu
2.2 About Screen
2.3 Main Menu Options
2.4 VDC Mode
2.4.1 Selecting a Voltage String
2.4.2 VDC Mode Sub-Menu
2.4.2.1 Add/Delete
2.4.2.2 Statistics
2.4.2.3 Graph
2.4.2.4 Limits
2.4.2.5 ->Flash USB
2.4.2.6 ->Print IRDA
2.4.2.7 Delete String
2.5 HYD Mode
2.5.1 Selecting a Hydrometer String
2.5.2 HYD Mode Sub-Menu
2.5.2.1 Upload New
2.5.2.2 Statistics
2.5.2.3 Graph
2.5.2.4 Limits
2.5.2.5 ->Flash USB
2.5.2.6 ->Print IRDA
2.5.2.7 Delete String
3.0 Power Saving Features
3.1 Auto-Off
3.2 Low Battery Indication
3.3 Checking Internal Battery Voltage

4.0 Deleting String Data and Editing est hresholds
4.1 Option 1: Using Winmeter 5.0 Software
4.2 Option 2: Manually
4.2.1 Deleting Individual VDC/HYD Strings
4.2.2 Deleting ALL (Voltmeter and Hydrometer) Strings
4.2.3 Editing Individual VDC/HYD String hreshold Limits
4.2.4 Remove ALL (Voltmeter and Hydrometer) hresholds Limits
5.0 aking DC Cell Voltage Measurements
5.1 Measuring DC Cell Voltages
5.2 Over Voltage Indication
5.3 Recording Over a Previous Measurement
5.4 Deleting a Previous Measurement
6.0 Uploading Hydrometer Data to the DLV50
6.1 ransferring Data from a DMA35 Digital Hydrometer to the DLV50
7.0 Connecting the DLV50 to PC/Winmeter 5.0
8.0 Upgrading DLV50 Firmware
For the most accurate results, please read and follow these instructions carefully.

1.0 Overview
The DLV50 data logging voltmeters have been designed specifically for the battery test industry.
The DLV50 is designed to:
• Measure and automatically record DC cell voltages bet een 0.1 VDC and 19.999 VDC (inclusive)
• Upload and analyze hydrometer data (specific gravity & temperature) from DMA35
hydrometers
The DLV50 is capable of operating in (2) distinct measuring modes:
(i) VDC Mode: The DLV50 can measure and store up to 2048 readings of cell voltages bet een
0.1 VDC and 19.999 VDC (inclusive). These readings are stored in 8 separate data strings of
256 readings, denoted A through H. The date and time of the last reading in each string is
also recorded.
(ii) HYD Mode: The DLV50 can receive and and store up to 2048 readings of specific gravity and
temperature from a DMA35 digital hydrometer. These readings are stored in 8 separate
data strings of 256 readings, denoted A through H. The date and time of the last reading in
each string is also recorded.
All stored readings can be do nloaded via Winmeter 5.0 soft are to generate detailed test reports
including statistical and graphical analysis and then stored into a custom database. This soft are
communicates ith the DLV50 via USB and allo s the User to set the time/date, change modes, delete
data string(s) and upgrade the DLV50 firm are via the PC interface. The readings can also be
transferred to a USB flash drive in .bdf (Winmeter) format.

2.0 Menu System
2.1 Main Menu
When turned ON, the DLV50 displays date, time and firm are revision for 3 seconds then displays the
“Main Menu”.
LEF SOF KEY
Push to accept the current
left soft key action.
Currently “ABOUT” to
select DLV50 “ABOUT”
screen.
ON/OFF:
“Short” push to turn ON
“Long” push to turn OFF.
UP & DOWN
Main or sub menu mode:
Push to change the current
selection.
Measurement mode: Push
to change selected
readings.
RIGH SOF KEY
Push to accept the current
right soft key action.
Currently “ENTER” to
select “VDC MODE”.
Green text and cursor
highlights selection
Current
menu
Left soft key description Right soft key description
Regardless of DLV50 status, repeatedly pressing the left soft key ill return the unit to the Main
Menu (unless the DLV50 is connected to a PC via USB).
VDC Mode
HYD Mode
Export ALL
Delete ALL
Reset limits
Date & ime
ABOU
EN ER
MAIN MENU

2.2 About Screen
Press the left soft key (belo “ABOUT”) to display the “About DLV50” screen.
SELEC VDC S RING
2.3 Main Menu Options
From the “Main Menu”, use the up/do n keys to highlight the appropriate option then push the right
soft key (belo the “BACK” button) to select that option.
There are 6 options from the main menu:
VDC Mode: Select to vie , analyze, edit or measure DC cell voltages. The DLV50 stores up to 8
strings of 256 readings stored in strings A through H.
HYD Mode: Select to vie , analyze or upload additional strings of hydrometer reading from a
DMA35 hydrometer. The DLV50 stores up to 8 strings of 256 readings stored in strings A
through H. Both specific gravity and temperature are stored for each cell.
Export ALL: Select to export all strings of data (both voltage and hydrometer) to USB Flash drive.
Delete ALL: Select to delete all data in all strings (both voltage and hydrometer).
Reset Limits: Select to delete all high and lo threshold alarm limits for voltage and hydrometer
readings.
Date & ime: Select to vie and/or edit the DLV50 date and time setting.
02/14/2012 12:05:27
Firmware Rev:
000.009
Calibrated:
01/15/2012
Battery 85%
BACK
ABOU DLV50
Current date & time
Current menu
Press left soft key to
return to the Main Menu
Firm are revision
Date last calibrated
State of internal battery
charge
Individual strings can be deleted by selecting the “Delete String” option of the VDC or HYD
mode sub-menu OR by connecting the unit to the Winmeter 5.0 soft are.
Individual limits for particular strings can also be deleted by selecting the “Limits” option of the
VDC or HYD mode sub-menu OR by connecting the unit to the Winmeter 5.0 soft are.
The date and time setting is automatically synced ith the PC date and time henever the
DLV50 is connected ith the Winmeter 5.0 soft are

2.4 VDC Mode
To select VDC Mode, from the “Main Menu” use the up/do n keys to highlight “VDC Mode” then
push the right soft key (belo “EN ER”) to select.
Select the “VDC MODE” to vie , analyze, export to USB flash drive, print via IRDA, edit or add to stored
DC cell voltages.
The DLV50 stores up to 8 strings of 256 readings stored in strings A through H.
Once “VDC Mode” is selected the user then selects hich string (A through H) to open. Each string is
displayed together ith the number of contained readings and the date the last reading as taken.
2.4.1 Selecting a Voltage String
Use the “UP” & “DOWN” keys to highlight the required string then push the right soft key (belo
“EN ER”) to select/open the string.
A 048 02/08/12
B 000 --/--/--
C 000 --/--/--
D 000 --/--/--
E 000 --/--/--
F 000 --/--/--
G 000 --/--/--
H 048 02/08/12
BACK
EN ER
SELEC VDC S RING
String A (48 readings, last
readings taken
2/8/12)
Current
menu
String D (empty)
String H (48 readings, last
readings taken 2/8/12)
Press left soft key to return
to the “Main Menu”.
Press right soft key to
select highlighted string.
02/08/12 14:50
001 +2.023 VDC
002 +2.227 VDC
003 +2.237 VDC
004 +2.423 VDC
005 +2.223 VDC
BACK
MENU
VDC String A:048
Date and time last
reading as taken
Current menu
Currently selected
reading (001)
Press the left soft key to
return to the “SELECT VDC
STRING”.
Press the right soft key to
initiate the sub-menu for
VDC String A.

Reading 001 “+2.023” is highlighted in blue to sho it is belo the lo threshold voltage of string A.
Reading 004 “2.423” is highlighted in red to sho it is above the high threshold voltage of string A.
Threshold levels are optional and editable.
To scroll through all voltage readings in String A, use the “UP” and “DOWN” keys.
2.4.2 VDC Sub-Menu
To enter the VDC sub-menu press the right soft key (belo “MENU”).
VDC Sub-Menu Options:
Use the up/do n keys to highlight the appropriate option then push the right soft key (belo
“EN ER”) to select that option.
There are 7 options to select from the VDC sub-menu:
Add/Delete
Statistics
Graph
Limits
->Flash USB
->Print IRDA
Delete String
Add/Delete
Statistics
Graph
Limits
-> Flash USB
-> Print IRDA
Delete String
BACK
EN ER
VDC
String A:048

2.4.2.1 Add/Delete:
Select to measure/store, delete or insert DC cell voltages.
Refer to aking a DC Voltage Measurement for additional instructions.
2.4.2.2 Statistics:
Select to vie statistics for the current VDC string.
2.4.2.3 Graph:
Select to vie graphical analysis of current VDC string.
+0.000
048 +2.023 VDC
047 +2.227 VDC
046 +2.237 VDC
045 +2.423 VDC
044 +2.223 VDC
BACK
MENU
A:048 Sum:102.3
Cell Voltage:
Sum: 102.3
Avg: 2.025
Max: 2.473 [023]
Min: 1.964 [018]
BACK
VDC String A:048
A:008 +2.323V
1.9
2.2
2.5
BACK

2.4.2.4 Limits:
Select to vie , remove or edit the high and lo threshold voltage limits for the string.
2.4.2.5 -> Flash USB:
Select to export the current VDC string to a .bdf file to a USB flash drive connected to the DLV50 USB
port. This file can later be transferred to a PC and opened ith Winmeter 5.0 soft are.
2.4.2.6 -> Print IRDA:
Select to print the current VDC string to a .bdf file to a USB flash drive connected to the DLV50 USB
port.
2.4.2.7 Delete String:
Select to delete all VDC data in the current VDC string.
This process cannot be undone!
2.5 HYD Mode
To select HYD Mode, from the “Main Menu” use the up/do n keys to highlight “HYD Mode” then
push the right soft key (belo “EN ER”) to select.
Select “HYD MODE” to upload hydrometer data from a DMA35 digital hydrometer, then vie , analyze,
export to USB flash drive, print via IRDA.
The DLV50 can upload and store up to 8 strings of 256 readings (specific gravity & temperature) stored
in strings A through H.
Once HYD Mode is selected the user then selects hich string (A through H) to open. Each string is
displayed together ith the number of contained readings and the date the last reading as taken.
A 128 02/08/12
B 000 --/--/--
C 000 --/--/--
D 000 --/--/--
E 000 --/--/--
F 000 --/--/--
G 000 --/--/--
H 048 02/08/12
BACK
EN ER
SELEC HYD S RING
String A (128 readings, last
readings taken 2/8/12)
Current menu
String D (empty)
String H (48 readings, last
readings taken 2/8/12)
Press left soft key to return
to the “Main Menu”.
Press right soft key to
select highlighted string.
Tabla de contenidos
Manuales populares de Instrumento de medición de otras marcas

Endress+Hauser
Endress+Hauser Proline Promag 50 Especificaciones técnicas

Siemens
Siemens SITRANS F Coriolis FCT030 Manual de lista de piezas

KLINGER
KLINGER CMF V Series Manual de usuario

EXFO
EXFO FTB-2 Manual de operación y mantenimiento

Keysight
Keysight M8290A Manual de usuario

ADTEK
ADTEK MW-5 Manual de usuario