TABLE OF CONTENTS
1. Scope of Delivery 3
2. Warning / Safety 4
3. Introduction GENIUS LED 100 5
4. Controls and Display Elements 6
5. Installation and Start-Up 7
5.1 Inserting / Changing batteries 7
5.2 Installation at the Radiator 8
5.3 Adapters 9
5.4 Adaptation 10
5.5 Disassembly 10
6. Main Functions 11
6.1 Temperature Setting 11
6.2 Self-Learning-Function 11
6.3 Fast-Link-Technology 12
7. GENIUS App 13
7.1 Settings (App) 13
7.2 Temperature (App) 14
7.3 Heating Profile (App) 14
7.4 Holiday Function (App) 15
7.5 Support (App) 15
8. Further Functions 16
9. Cleaning and Storage 16
10. Error Messages and Help 17
11. Technical Specifications 18
12. Support and Contact 18
13. Environmental Information 19
14. Warranty 19
The following operating instructions will guide you during commissioning and use of your GENIUS LED 100 and answer
all essential questions. Please read these operating instructions carefully before using your GENIUS LED 100.

Page 3
GENIUS LED100
1. SCOPE OF DELIVERY
1x GENIUS LED 100
1x Quick Start Guide
3x Adapters (Danfoss RA / RAV / RAVL)
1x Screw for adapter
EIN
GENIUS LED 100
Energy-saving controller
Screw
for adapter
* When using the RAV adapter, you need the
RAV Pin for the extension of the valve stem.
RAV
RA
RAVL
RAV Pin*
NOTE: The following figures are for illustrative purpose only and can differ from the real product.
NOTE: Please check the delivery scope for completeness.

Page 4
GENIUS LED100
2. WARNING / SAFETY
WARNING! This signal word indicates a hazard with a medium degree of risk which, if not avoided, may result in death
or serious injury.
NOTE! This signal word warns of possible material damage.
SAFETY INSTRUCTIONS
- GENIUS LED100 is designed for use in buildings.
- Operate GENIUS LED100 only as described in the user manual
- GENIUS LED100 should only be put to use in a dry and dust-free place, away from direct sunlight.
- Do not keep using the device when ther is obvious damage.
- GENIUS LED100 may not be rerebuilt, modified or opened
WARNING! RISK OF EXPLOSION!
Improper handling of batteries can lead to explosion.
- Do not heat batteries and do not throw batteries into an open fires.
- Do not place batteries in direct sunlight.
- Protect batteries from excessive heat.
- Do not short-circuit the batteries.
- Never attempt to charge non-rechargeable batteries.
- Never disassemble batteries.
- Do not use new and used batteries together.
- Observe the correct polarity (+/-) when inserting the batteries.
- Before inserting the batteries, clean the batteries and the contacts in the thermostat.
WARNING! RISK OF ACID BURNS!
Leaking battery acid can lead to burns.
- Avoid contact of battery acid with skin, eyes and mucous membranes.
- In case of contact with battery acid, rinse the affected areas immediately with plenty of clear water and consult a
doctor.
WARNING! RISK OF INJURY!
When children play with the thermostat or packaging, they might swallow small parts and suffocate.
- Do not let children play with the thermostat or packaging.
- Keep batteries away from children. Seek medical attention immediately if batteries are swallowed.
WARNING! SENSITIVITY TO LIGHT!
Some people may have epileptic seizures if they are exposed to certain light effects, even if no previous incidents are
known.

Page 5
GENIUS LED100
3. INTRODUCTION GENIUS LED100
Thank you for purchasing a product from Eurotronic Technology GmbH. This device is designed to adjust the tempera-
ture in your rooms comfortably and completely according to your needs while helping you to reduce your heating costs
effectively.
All development and production are 100% „Made in Germany“, guaranteeing the highest quality and technology stan-
dards. These operating instructions will help you to put your device into operation quickly and easily.
GENIUS LED 100
GENIUS LED 100 is an energy-saving controller for radiators equipped with Fast-Link technology for modern and simple
operation. It regulates your room temperature automatically according to your settings by means of a self-learning
function or conveniently via your smartphone using Fast-Link.
30%
Bis zu
Touch control
enables perfect control as well as simple
and clear operation.
Fast-Link technology
transmits your heating plan, individu-
ally created in the app, contactlessly.
Simple installation
without intervention in the heating system.
Save heating costs through
energy-efficient control.
Self-Learning function
records your everyday routines and
automatically creates an individual
heating profile for you.

Page 6
GENIUS LED100
EIN
4. CONTROLS AND DISPLAY ELEMENTS
To enter the menu, press the MENU button. Use the PLUS/MINUS buttons to navigate through the menu.
In normal mode, you can set the temperature with PLUS and MINUS.
PLUS
Increase temperature /
navigate through menu
MINUS
Decrease temperature /
navigate through menu
MENU
Get to the menu
OK/SET
Confirm
Key lock (S. 16)
Self-Learning-Mode (S. 11)
Assembly/Disassembly (S. 8)
Fast-Link (S. 12)
Window-open-detection (S. 16)
Battery level
LED-Bargraph:
Menu items / Functions
Manual Operation:
Use PLUS/MINUS to manually change the room temperature at any time. In AUTO mode, this manually set
temperature remains until the next setting point. GENIUS LED 100 then switches back to the set heating pro-
gramme.

Page 7
GENIUS LED100
5. INSTALLATION AND START-UP
F
i
g
.
1
F
i
g
.
2
1. Remove the battery cover by pulling it upwards at the notch (Fig. 1).
2. Now insert the batteries. Pay attention to the correct polarity! Do not use rechargeable batteries.
3. Place the battery cover back on the GENIUS LED 100 (Fig. 2) by pressing until it clicks.
5.1 INSERTING/CHANGING BATTERIES
BATTERY:
If the batteries are weak, the battery LED
will flash continuously until the batteries are changed.

Page 8
GENIUS LED100
INBETRIEBNAHME
GENIUS LED 100 can easily be mounted on all known valve bodies (see adapter list at: https://eurotronic.org/service/
faq).
1. Unscrew the old thermostatic head completely, loosen the fastening and pull it off the valve (Fig. 3)
2. If necessary, select a suitable adapter and mount it on the valve (Fig. 4)
3. Screw the thermostat onto the valve or adapter by turning the union nut clockwise (Fig.5).
CAUTION:
Make sure that the device is in the installation mode even if it is installed/removed later.
Only assemble/disassemble in this position.
5.2 INSTALLATION AT THE RADIATOR
F
i
g
.
4
F
i
g
.
3
F
i
g
.
5

Page 9
GENIUS LED100
5.3 ADAPTERS
For the following valves no adapter is required:
Heimeier; Junkers Landys+Gyr; MNG; Honeywell; Braukmann, as these have a thread of M30x 1,5mm. The adapters
for Danfoss RAV (pin must be plugged on the valve tappet) Danfoss RA and Danfoss RAVL are included.
For the following valves you need an adapter:
Herz M28 x 1,5 mm; Comap M28 x 1,5 mm; Vaillant 30,5 mm; Oventrop M30 x 1,0 mm; Meges M38 x 1,5 mm; Ondal
M38 x 1,5 mm; Giacomini 22,6 mm; Rossweiner M33 x 2,0 mm; Markaryd M28 x 1,0 mm; Ista M32 x 1,0 mm; Vama
M28 x 1,0 mm; Pettinaroli M28 x 1,5 mm; T+A M28 x 1,5 mm; Gampper 1/2/6; Danfoss RA/RAV/RAVL.
For additional adapters, please visit: http://shop.eurotronic.org
If you are not sure which valve you have, please visit: www.eurotronic.org/produkte/faq/ and check the adapter list.
RAV RA RAVLRAV Pin
HINWEIS:
Remove the connectors of the plastic adapters completely (Fig. 6) before using one of the included adapters! For Dan-
foss RA/RAV, use the enclosed screw and nut.
Fig. 6

Page 10
GENIUS LED100
5.5 DISASSEMBLY
To remove the GENIUS LED 100, press the MENU button on your controller. Use PLUS/MINUS
to navigate to the menu item for Assembly/Disassembly and confirm with OK/SET. A running
light is indicated by the LEDs. Wait briefly until the setting LED flashes. Now turn the union nut
counterclockwise and remove the GENIUS LED 100 from the valve (Fig. 7).
F
i
g
.
7
After installation, GENIUS LED 100 can start adapting. The LED for Assembly/Disassembly is already flashing, con-
firm the adaptation by pressing and holding the OK/SET button (3 seconds). The adaptation starts after confirmation.
The device now adapts to the stroke of your valve body. To do this, the valve is now opened and closed several times to
learn the respective end points. A running light is indicated by the LEDs. After successful adaptation, the GENIUS LED
100 switches to normal operation and the LEDs indicate the setpoint temperature. After approx. 5 seconds the ther-
mostat switches to standby mode.
|If a new adaptation is necessary, e.g. if your radiator does not become cold in the OFF position, please select Assem-
bly/Disassembly in the menu. Confirm with OK/SET (3 seconds) and start the adaptation again
|When the Assembly/Disassembly LED flashes again, place the GENIUS LED 100 on the radiator valve and then
briefly remove the batteries to reset.
5.4 ADAPTATION