Eurotronic Air Quality SensorZ-Wave Plus Instrucciones de funcionamiento originales

www.eurotronic.org
Made in Germany
Air Quality Sensor Z-Wave Plus
EN
Installation & Operation Guide

1 Included in delivery 3
2 Safety Instructions 4
3 Intended Use 4
4 Product description 5
5 Operating the device 6
5.1 Button 6
5.2 LEDs 6
6 Network behavior 7
6.1 Power supply 8
6.2 Add to a Z-Wave network (Inclusion) 8
6.3 Remove from a Z-Wave network (Exclusion) 8
6.4 Factory reset 9
7 Z-Wave 9
Content
8 Association 10
9 Conguration 10
10 Multilevel Sensor 11
11 Notication 11
12 Troubleshooting 12
13 Cleaning 12
14 Technical specications 12
15 Disposal 13
16 Warranty 13
17 Contact information 13

– 3 –
1 x Air Quality Sensor Z-Wave Plus
1 x Micro USB power supply
1 x Quick Start Manual
1. Included in delivery
Air Quality Sensor Z-Wave Plus
Micro USB power supply
Quick Start Manual
NOTE! Please check the scope of delivery for completeness and intactness.
NOTE! The following figures are for illustration purposes only and may differ from the actual product.

– 4 –
Avoid potential dangers by reading the following safety instructions carefully.
SAFETY INSTRUCTIONS
- Air Quality Sensor Z-Wave Plus is designed for use in buildings.
- Operate Air Quality Sensor Z-Wave Plus only as described in the user manual.
- Air Quality Sensor Z-Wave Plus should only be put to use in a dry and dust-free place, away from direct
sunlight.
- Do not keep using the device when there is obvious damage.
- Air Quality Sensor Z-Wave Plus may not be rebuilt, modified or opened.
WARNING!
Risk of fatal injury and accidents to infants and children! The packaging material represents a risk of suff
ocation. Never leave children unattended when the packaging material is nearby.
Children often underestimate the risks involved. Always keep children away from the packaging material.
The device is not a toy.
2. Safety Instructions
The product provides comprehensive information on indoor air quality.
For reasons of safety and approval (CE), you must not modify and/or alter the product. If you use the prod-
uct for purposes other than those described, the product may be damaged. In addition, improper use may
result in hazards such as short circuits, fire, electric shock, etc.
Read the operating instructions carefully and keep them in a safe place. Only pass the product on to third
parties together with the operating instructions.
3. Intended use

– 5 –
The brand new Z-Wave sensor in an ultra slim design housing provides comprehensive information on indoor
air quality. Based on these information it is possible to always ensure a healthy living climate.
• Ultra-flat design housing
• Use of high-precision, Swiss sensor technology
• Multicolor LED for signalling ventilation recommendations
• Returns the following values:
- VOC value (volatile organic compounds) in ppm
- CO2 value (as CO2 equivalent) in ppm
- Temperature (°C) and humidity (%)
- Dew point (°C)
• Supports Z-Wave Plus S2 security (encryption)
• Z-Wave repeater function
• Operation with plug-in power supply unit
4. Product description

– 6 –
5.1 Button
5. Operating the device
Button Interaction Result/Behavior
Network press three times
within 1 second
Air Quality Sensor Z-Wave Plus will react to inclusion or exclusion
commands.
Network hold for 10 seconds Factory resets the Air Quality Sensor Z-Wave Plus.
5.2 LEDs
Color State Meaning
red permanently illuminated Air quality is bad.
(LED signaling can be disabled via Configuration Command Class)
orange permanently illuminated Air quality is average.
(LED signaling can be disabled via Configuration Command Class)
green permanently illuminated Air quality is good.
(LED signaling can be disabled via Configuration Command Class)
red lights constantly for
5 seconds
A task has failed.
green blinking Device is ready to be included or excluded.
green lights constantly for
5 seconds
A task was completed successfully.
2x red
3x green
blinking pattern LGS Z-Wave Plus is reset to factory default settings.
LED-Anzeige

– 7 –
On factory default the device does not belong to
any Z-Wave network Air Quality Sensor Z-Wave
Plus needs to be added to an existing wireless
network to communicate with the devices of this
network. This process is called Inclusion.
Air Quality Sensor Z-Wave Plus can also be
removed from a network. This process is called
Exclusion. Both processes are initiated by the
primary controller of the Z-Wave network. This
controller is turned into exclusion respective
inclusion mode. Please consult the manual of your
Z-Wave Controller how to activate Inclusion or
Exclusion mode.
If Air Quality Sensor Z-Wave Plus has been added
to a network, it has to be removed prior to be
added to another wireless network.
Interoperability
This product can be operated in any Z-Wave
network with other Z-Wave certified devices from
other manufacturers. All non-battery operated
nodes within the network will act as repeaters
regardless of vendor to increase reliability of the
network.
Security
Air Quality Sensor Z-Wave Plus supports secure
communication. Air Quality Sensor Z-Wave Plus
will communicate with other devices secure as
long as this device provides the same or a higher
level of security. Otherwise Air Quality Sensor
Z-Wave Plus will automatically turn into a lower
level of security.
A Security Enabled Z-Wave Controller must be
used to fully utilize the Air Quality Sensor Z-Wave
Plus.
6. Network behavior

– 8 –
Start inclusion mode of your primary Z-Wave Controller.
Press the network button three times within 1 second.
While the inclusion is active, the LED is blinking green. If the inclusion was successful the green LED will light
up for 5 seconds. Otherwise the red led will light up for 5 seconds to indicate failure.
Start Exclusion mode of your primary Z-Wave Controller.
Press the network button three times within 1 second.
While the inclusion is active, the LED is blinking green. If the inclusion was successful the green LED will light
up for 5 seconds. Otherwise the red led will light up for 5 seconds to indicate failure.
6.2 Add Air Quality Sensor Z-Wave Plus to a Z-Wave network
6.3 Remove Air Quality Sensor Z-Wave Plus from a Z-Wave network
6.1 Power supply
Connect the Micro-USB cable to a AC adapter and
to the air quality sensor and afterwards to a power
outlet.

– 9 –
7. Z-Wave
Command Class Description Version Control (C)
Support (S)
Security *
Association Allows to associate with other Z-Wave devices. 2 S U, S0, S2
Association
Group Information
Allows to group associations. 1 S U, S0, S2
Configuration Allows to configure the device settings. 1 S U, S0, S2
Device Reset
Locally
Informs the Z-Wave Controller that the device was factory
reset.
1 S U, S0, S2
Firmware Update
Meta Data
Allows Over the Air Update of the device. 3 S U, S0, S2
Manufacturer
Specific
Provides information about manufacturer and product. 1 S U, S0, S2
Multilevel Sensor Provides sensor treadings. 10 S U, S0, S2
Notification Informs the controller about system events. 8 S U, S0, S2
Power Level Used to alter the rf-power (required by Z-Wave). 1 S U, S0, S2
Security Allows encrypted Z-Wave communication. 2 S U
Supervision Transmits Z-Wave Commands with an execution
confirmation.
1 S U
Transport Service Handles the transmission of large telegrams. 2 S U
Version Returns information about the firmware. 2 S U, S0, S2
Z-Wave Plus Info Identifies the device as a Z-Wave Plus device. 2 S U
* Availability of the Command Class after adding the Air Quality Sensor Z-Wave Plus to your Z-Wave network
U Unsecure
S0 Z-Wave Security standard S0
S2 Z-Wave Security standard S2
Press and hold the network button for at least 10 seconds. The Air Quality Sensor Z-Wave Plus will indicate
the reset blinking pattern once the reset is completed.
Please use this procedure only when the network primary controller is missing or otherwise inoperable.
6.4 Factory reset

– 10 –
Air Quality Sensor Z-Wave Plus can be associated with other devices.
Group No. Description Commands Max supported
Nodes
1 Lifeline DEVICE_RESET_LOCALLY_NOTIFICATION,
NOTIFICATION_REPORT,
SENSOR_MULTILEVEL_REPORT,
1
2 Temperature SENSOR_MULTILEVEL_REPORT 5
8. Association
9. Conguration
Air Quality Sensor Z-Wave Plus can be configured during runtime.
Paramter
number
Size
in Byte
Name Description
1 1 Temperature on
Change Reporting
0x00 No on change reporting (only time-based reports).
0x01 - 0x32 report if temperature changed by delta = 0,1°C - 5,0°C
default: 0x05
2 1 Humidity on Change
Reporting
0x00 No on change reporting (only time-based reports).
0x01 - 0x0A report if humidity changed by delta = 1% …10%
default: 0x05
3 1 Unit Temperature 0x00 Temperature reports in Celsius
0x01 Temperature reports in Fahrenheit
default: 0x00
4
1
Resolution Tempe-
rature
0x00 No resolution (example 22°C)
0x01 1/10 resolution (example 22.3°C)
0x02 1/100 resolution (example 22.35°C)
default: 0x01
5 1 Resolution Humidity 0x00 No resolution (example 33%)
0x01 1/10 resolution (example 33.4%)
0x02 1/100 resolution (example 33.45%)
default: 0x00
6 1 VOC-on Change
Reporting
0x00 No on change reporting (only time-based reports)
0x01 - 0x0A report if VOC reading changed by 100ppb - 1000ppb
default: 0x05
7 1 CO�eq on Change
Reporting
0x00 No on change reporting (only time-based reports)
0x01 - 0x0A report if CO2eq reading changed by 100ppm - 1000ppm
default: 0x05
8 1 Air quality indicati-
on via LED
0x00 No air quality indication via LEDs
0x01 Indicate measured air quality via LEDs
default: 0x01
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Otros manuales de Accesorios de Eurotronic