Replace the end terminal
cover and fasten the screws.
End terminal cover with
cable entry blanks removed.
Terminate the wires to the
respective terminals.
Cut and remove the side and rear cable entry blanks from the
end terminal cover.
Loosen the screws with Philips
head screw driver, and remove
the end terminal cover.
Flip open and hold the soft flap in position. Insert the bit of
the flat head screw driver into the slot, push down at a 45°
angle to release the catch.
Insert the end terminal into
the anchor, pushing it all the
way until a ‘click’ sound is
heard to secure the end
terminal.
Refer to SFC3 Guide
(DMK-005-023) for steps to
attach backplates.
13
24
DMK-005-016-03 ENG
Installation
5
CABINET/
OFFICE
FURNITURE
Remove the top cover of the internal/
external corner cap before attaching to
housing. Refer to (a) and (b) on the right
for instructions on removing the top cover.
Top cover to be
removed
6 7
ii
(a) Removing the top cover of internal corner cap
(b) Removing the top cover of external corner cap
iii iv v
ii iii iv v
A. INSTALLING INTERNAL CORNER JOINT
B. INSTALLING EXTERNAL CORNER JOINT
For installation of internal and external corner joints, refer to “Corner Joint Installation”.
3
7
Attach external corner cap to complete installation.
5
6
Attach corner link onto top of housing as shown. * Terminate cables and
install power track, data
housing and blank cover.
4
Break and remove inner latch on corner link as shown. Attach corner link onto bottom of housing as shown.
REMOVAL OF CORNER CAP TOP COVER FOR INSTALLATION OF SH1 UNDER CABINET OR FURNITURE FIXTURE
i
i
Trim Line
Trim Line
INTERNAL CORNER JOINT
EXTERNAL CORNER JOINT
1 2
Follow step 6 to 12 of
“Installation (A)” sequence to
secure and prepare housing.
Follow step 1 to 5 of
“Installation (A)” sequence
to prepare SH1 housing.
Align housing to wall with
reference to “Corner Joint
Guide”.
B. INSTALLING SFC3 MODULAR TRACK SIDE TERMINATION
8 9 10
Wherever necessary, snap
blank cover onto housing.
Snap SFC3 Modular Track
onto housing.
C. INSTALLING DATA POINT
23
Wherever necessary, snap
blank cover onto housing.
Route data cable
through mounting frame.
514
Snap mounting frame
onto housing.
Attach data jack to DS4
data housing with reference
to DS4 User Guide
(DMK-006-010).
Terminate data cable to
data jack.
8
1 2
6
Drill mounting holes on
marked locations.
Align housing to the wall
and insert wall plugs into
drilled holes.
Use the SH1 retainer to secure data cables to the
compartment as shown.
Mark out the positions of cable entry and mounting openings on drill lines provided on the
back of the housing. FIG. A shows the positions of cable entry and mounting openings.
Drill holes at marked locations for cable entry and mounting openings. Use a hole saw
for the power cable entry holes.
Route power and data cables through cable entry
openings and prepare to mount the housing.
4
Using a screwdriver, secure
end cap with screws
provided.
9
Mark out positions of
mounting holes onto the
wall.
7
13
3
Attach end cap to housing.
5
Attach screw caps. Repeat
steps 4 to 6 on opposite
end of housing if corner
joint is not required.
Push data cables into the
data compartment.
12
A. MOUNTING SH1 HOUSING
Snap data housing
onto mounting frame.
6
Installation of Corner Joints
FIG. A
Tighten screws to secure housing onto the wall. FIG. B
shows an example of mounting openings with screws
attached.
10
Data Cable Entry
Power Cable Entry
Mounting Opening
FIG. B
3
8
Follow step 6 to 12 of
“Installation (A)” sequence to
secure and prepare housing.
Attach internal corner cap to complete installation.
5
6 7
* Terminate cables and
install power track, data
housing and blank cover.
4
Attach corner link onto bottom of housing as shown. Attach corner link onto top of housing as shown.Follow step 1 to 5 of
“Installation (A)” sequence
to prepare SH1 housing.
1 2
Align housing to wall with
reference to “Corner Joint
Guide”.
37mm
* For side termination of SFC3 Modular Track, refer to “Installation (B)”
For installation of data points, refer to “Installation (C )”.
8
11
If extension of the housing
length is required, use the
housing joint pin to align
the additional SH1 housing.
Kindly visit our website at www.eubiq.com for product warranty information. ALL RIGHTS RESERVED. EUBIQ AND GSS ARE THE REGISTERED TRADEMARKS OF EUBIQ PTE LTD.
* For side termination of SFC3 Modular Track, refer to
“Installation (B)”
For installation of data points, refer to “Installation (C )”.
37mm