South Bend, Indiana USA | networketi.com ADH INSTRUCTION MANUAL | PART NO.24108 REV B
8
10. Connect the green power connector
from the new inlet solenoid module
where the original power connector
had been, then tighten the two captive
end screws to secure it in place.
11. Reinstall the front cover removed in
step 4 of this section. If it was placed
upside down on the lid of the unit
during this procedure, carefully turn the
cover back over and work it back into
position, past the wires and other
components in the enclosure. Reinstall
the four corner screws securing the
front cover to the chassis.
12. Reconnect the ground wire by inserting
it behind the retaining screw from
which it was removed, then tighten the
retaining screw. Reconnect the green
power connector by holding it in place
then tightening the two captive screws
removed in step 3 of this section.
Reconnect both ends of the orange
ethernet cable removed in step 3 of this
section. It does not matter which end of
the ethernet cable goes into which
receptacle.
13. With the ground wire, power connector
and ethernet cable connected, close
the NEMA enclosure and secure the
two latches. Secure the lid in place by
reinstalling the captive screws in the
two outer corners of the lid.
14. Restore machine power by plugging
the unit back in.
QUESTIONS AND COMMENTS
For technical help, questions, or
comments concerning this or any
ETI, Inc., product, contact the
Customer Service Department
between 8:00 a.m. and 5:00 p.m. EST.
DISCLAIMER
ETI, Inc. makes no representations or
warranties, either expressed or implied
with respect to the contents of this
publication or the products that it
describes, and specifically disclaims any
implied warranties of merchantability or
fitness for any particular purpose. ETI,
Inc. reserves the right to revise this
publication and to make changes and
improvements to the products
described in this publication without the
obligation of ETI, Inc. to notify any
person or organization of such
revisions, changes or improvements.
No part of this manual may be
reproduced or translated in any form or
by any means, electronic or mechanical
including photocopying and recording,
for any purpose without the express
written consent of ETI, Inc.
The ETI logo, We Manage Heat, and
ADH are registered trademarks of ETI,
Inc. NETCOM is a trademarknc. NETCOM is
Copyright © 2012 ETI, Inc. All rights
reserved.