Preparing RadioSecure SLM for deployment:
RadioSecure SLM with fully charged battery is stored with reset plug inserted
and securely tightens. The reset plug disconnects power supply to the CCA.
The following procedure and visual observations should be observed in
deploying the RadioSecure SLM.
1. Slide the interface connector window to left, unscrew green reset plug.
2. Red LED start blinking for approximately 45s (system initialization).
3. Red LED latched (system completed initialization).
4. Red and Green LED latched (GSM initialization).
5. Red LED latched, Green LED blink (GSM primary login).
6. Green LED latched (RadioSecure SLM ready for commissioning).
7. Insert header end of the stainless steel wire rope into the larger hole on
the top of RadioSecure SLM.
8. Insert Horizontal Bolt and lock it with locking barrel.
9. Pass stainless steel wire rope through the hasp of object to be sealed and
insert the taper end of the cable through the smaller hole.
10. Pull to seal tight.