Programming the ‘On Board’ Trades Time-Clock
On switch on of the system the screen will display ENTROTEC. Then display the Date, the day of the week, the timer status on line 1.
Then time of day, nxon (next on period of timer) and the next on time as example below.
Note: When nxon displays 00;00
the Next on period is during subsequent day.
Features:
Up to 12 daily on/off periods can be programmed:
5 day week, by weekend, or an individual day basis.
Time-clock settings:
If at anytime the timer is left for more than 10 seconds without any button ‘pushes’ it first asks if you would like to erase all settings ‘N’
for no being highlighted but to change to ‘Y’ for yes press the right button and then press Prog to confirm and save the settings. Or after
a further 10 seconds it asks you if you want to ‘Save Changes’ with again ‘N’ and ‘Y’ as above or leaving it alone for a further 10 seconds
the timer reverts to original ‘non-programming’ mode.
To Change Date and Time: Press Prog button and the year will be displayed. To change the year press the Up button until the correct
year is displayed or if already correct press the Prog button again to display the month setting and press the Up button to correct the
month setting or if correct press the Prog button again to adjust the day setting by using the Up button. To change the time press the
Prog again and using the Right button select the hours, minutes or seconds that you want ot adjust and adjust using the Up button.
When any of the above have been adjusted leave for 10 seconds and the Save Changes Y/N screen will appear highlighting ‘N’ to save
your settings press the Right button to highlight ‘Y’ and press the Prog button.
30/08/07 THU ON
09;17 nxon 11;30
Timer On
Timer Off
Led’s showing time-clock status
16 x 2 LCD Module
for Trade Clock Setting
Prog Right UP
SN SB DO CA SN SB DO CA
Door ‘B’ ConnectionsDoor ‘A’ Connections
RG59 to
Camera
RG59 to
Camera
SN SB DO CA SN SB DO CA
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
PL1
PL8 PL12 PL21 PL21
PL29
RG59 Crimp
Connector
RG59 Crimp
Connector
12 volt DC supply
PL17 +12V / 0v
Camera Camera
Camera signals are automatically switched from
Door ‘A’ to Door ‘B’ when calls are generated.
Preset Adjustments
Video Adj.
Speech
Time
Callup
Time
Call Tone
Time
Reassurance
Volume
Door A
Lock Timer
Door B
Lock Timer
++
++ +
+
To Change the Daily (DLY) On & Off Times. Press the Prog button 6 times and DLY 1 will be highlighted and it’s condition i.e On or
Off. To change the condition press the Up button. To adjust the time period first press the Right button to highlight either the hours
or minutes and use the Up button to adjust the time, leave for 10 seconds and the Save Changes Y/N screen will appear highlighting
‘N’ to save your settings press the Right button to highlight ‘Y’ and press the Prog button.
To Change the Week day (M-F) On & Off Times. Repeatedly press the Prog button until M-F 1 will be highlighted and it’s condition
i.e On or Off. To change the condition press the Up button. To adjust the time period first press the Right button to highlight either
the hours or minutes and use the Up button to adjust the time, leave for 10 seconds and the Save Changes Y/N screen will appear
highlighting ‘N’ to save your settings press the Right button to highlight ‘Y’ and press the Prog button.
To Change the Weekend (WKN) On & Off Times. Repeatedly press the Prog button until WKN 1 will be highlighted and it’s condition
i.e On or Off. To change the condition press the Up button. To adjust the time period first press the Right button to highlight either
the hours or minutes and use the Up button to adjust the time, leave for 10 seconds and the Save Changes Y/N screen will appear
highlighting ‘N’ to save your settings press the Right button to highlight ‘Y’ and press the Prog button.
To Change the Individual Day (Mon) On & Off Times. Repeatedly press the Prog button until MON 1 (or the appropriate day) will be
highlighted and it’s condition i.e On or Off. To change the condition press the Up button. To adjust the time period first press the
Right button to highlight either the hours or minutes and use the Up button to adjust the time, leave for 10 seconds and the Save
Changes Y/N screen will appear highlighting ‘N’ to save your settings press the Right button to highlight ‘Y’ and press the Prog
button.
Trades Time-Clock Cont.
System Notes
A). If using 4 pair CW1308 or Cat5e cable on a flat that has multiple video handsets fitted (e.g. DDA flat) and the internal ringer is
enabled, BZ must still be connected to ensure correct operation of the call tone. To achieve this the DS function is lost. If DS is a
requirement then use CW1308 6 pair. Maximum distance between video handsets and controller when using 4 pair cable is 70 metres.
B). When using mains rated cables for locks etc. Always use flex rather than single core cables as single core cables put strain on the
terminal connectors.
C). Earth all metalwork connected to the system i.e. Door Panels, fire switches, push to exits etc.
D). Whilst Entrotec preset the power supplies to output 13.8v DC to charge batteries it is advisable that these are reset to 13.8v when the
system is under full load (with battery disconnected).
E). If using Easitag access control then user keys must be added to each door separately. Key-fobs are stored in the door panel PCB and
stand-alone readers. If these are replaced at anytime then it is advisable to swop IC2 so that all key information is retained rather than
retrieve keyfobs from residents. IC2 is the only IC that is removable and fitted in a socket. Ensure correct orientation.
F). If using automatic door openers then wire doorlocks as shown and using the spare relay connections, connect C & NO connections to
trigger the automatic door opener.
Note: it is imperative that a delay time delay of at least 1 second is set on the door opener. If this is not done then the opener will try to
open the door before the locks are released which will eventually burn out the motor.
Notch or dot towards
top of PCB
24LC16B
IC2
PL6(PL28)
BN
BE
Spare Volt
free conntacts
12v
NC
NO
C
NC
NO
To Door opener trigger inputs
2
1.5mm Flex to lock(s)
Video Schematic (Dual or Single Entrance)
Page 10 Page 11
Speech Time: Adjusts how long the user can talk for before the system resets, 10 seconds to 2 minutes.
Call-up Time: Adjusts how long the system stays 'live' for once a call has been made, 10 seconds to 2 minutes.
Call Tone Time: Adjusts how long the call tone is emitted to the handsets and front panel, 1 to 25 seconds.
Reassurance Volume: Adjusts the volume of the call tone at the front panels and should be set in accordance with 'on-site' conditions.
Door A/B Lock Timer: Adjusts the door open time period and should be adjusted to suit 'on-site' requirements. 1 to 30 Seconds.
Video adjustment: Adjusts the video balance to fine tune the video picture quality and should be adjusted 'on-site' to suit installation.
Prog Right UP