enraf SmartRadar FlexLine Manual de usuario

SmartRadar
FlexLine
©2007
Installation Guide

Table of contents FlexLine
A
Table of contents
1 General........................................................................... 1
1.1 Using this installation guide ......................................... 1
1.2 Related documents...................................................... 1
1.3 Trademarks.................................................................. 1
1.4 Contact ........................................................................ 1
2 Safety ............................................................................. 2
2.1 Correct for use............................................................. 2
2.2 Safety conventions ...................................................... 2
2.3 Safety instructions ....................................................... 2
2.4 Liability......................................................................... 3
2.5 Labels .......................................................................... 4
2.6 Personal safety............................................................ 5
2.7 Warnings and cautions ................................................ 5
2.8 Electrical ...................................................................... 7
2.9 Accordance to regulations ........................................... 7
2.10 Compliance to FCC, R&TTE........................................ 8
3 Product Description .................................................... 10
3.1 SmartRadar components........................................... 10
3.2 SmartRadar FlexLine................................................. 10
3.3 SmartView ................................................................. 12
3.4 SmartConn................................................................. 12
3.5 Configurations............................................................ 13
4 Installation ................................................................... 14
4.1 Safety ........................................................................ 14
4.2 Receipt....................................................................... 14
4.3 Storage ...................................................................... 15
4.4 Before installation ...................................................... 15
4.5 Installation overview .................................................. 16
4.6 Mechanical installation............................................... 17
4.7 Preparations for installation with SmartConn............. 18
4.8 Preparations for installation without SmartConn........ 19
4.9 Installing the cable glands and stopping plugs with
SmartConn................................................................. 21

FlexLine Table of contents
B
4.10 Installing the compound glands, conduits and stopping
plugs without SmartConn........................................... 22
4.11 Electrical connection.................................................. 23
4.12 Finishing installation with SmartConn........................ 34
4.13 Finishing installation without SmartConn................... 35
5 Technical data ............................................................. 36
5.1 Weights and dimensions............................................ 36

General FlexLine
1
1 General
1.1 Using this installation guide
For use in measurement systems for inventory measurement and control. The
SmartRadar Flexline can integrate data from other measurement devices, such as
temperature RTD sensors. Data from Radar and connected sensors can be
communicated to host computer systems via a variety of industry standard protocols.
1.2 Related documents
• SmartRadar FlexLine Safety instructions for installation, commissioning,
operation and maintenance, shipped with the device.
• Installation guide SmartRadar Antennas.
• CE Declaration of Conformity
• EC-Type Examination Certificate
• IECEx Certificate of Conformity
• FCC Authorization
• Control drawings for FM and CSA.
1.3 Trademarks
HART™ is a registered trademark of the HART Communication Foundation.
1.4 Contact
Enraf BV
PO Box 812; 2600AV Delft
Netherlands
E-mail: [email protected]
Website: http://www.enraf.com

FlexLine Safety
2
2 Safety
2.1 Correct for use
The SmartRadar FlexLine is a radar-based level gauge to use in inventory
measurement systems and can be used to interface with other systems and sensors
such as temperature gauges.
2.2 Safety conventions
"Warnings", "Cautions" and "Notes" are used throughout this installation guide to
bring special matters to the immediate attention of the reader.
• A Warning concerns danger to the safety of the technician or user.
• A Caution draws the attention to an action which may damage the equipment.
• A Note points out a statement deserving more emphasis than the general text, but
not requiring a "Warning" or a "Caution".
2.3 Safety instructions
2.3.1 Safety instructions
Refer to the safety instructions shipped with the device for installation,
commissioning, operation and maintenance.
2.3.2 EC declaration of conformity (for E.U.)
Refer to the EC declaration of conformity, shipped with the device.
2.3.3 Control drawings for FM & CSA
Refer to the control drawings shipped with the device.
2.3.4 Users
The mechanical and electrical installation must be carried out only by trained
personnel with knowledge of the requirements for installation of explosion proof
equipment in hazardous areas. The entire installation procedure must be carried out

Safety FlexLine
3
in accordance with national, local and company regulations. The entire electrical
installation shall be carried out in accordance with the national requirements for
electrical equipment to be installed in hazardous areas.
2.3.5 Additional information
If you require additional information, contact Enraf or its representative.
2.3.6 Environmental conditions
Observe the environmental conditions for the temperature and the pressure. Refer to
the chapter “Technical data”.
2.4 Liability
The information in this installation guide is the copyright property of Enraf B.V.,
Netherlands. Enraf B.V. disclaims any responsibility for personal injury or damage to
equipment caused by:
• Deviation from any of the prescribed procedures,
• Execution of activities that are not prescribed,
• Neglect of the safety regulations for handling tools and use of electricity.
The contents, descriptions and specifications in this installation guide are subject to
change without notice. Enraf B.V. accepts no responsibility for any errors that may
appear in this installation guide.
NOTE
Refer to EN IEC 60079-14 or NEC (NFPA70).
Warning!
Only certified technicians are authorized to make changes on the
SmartRadar configuration. All modifications must be in accordance to
the guidelines as set forth by Enraf. Modifications not authorized by
Enraf will invalidate the approval certificates.

FlexLine Safety
4
2.5 Labels
Fig. 2.1 Labels
A Identification label with safety note.
Fig. 2.2 Identification label (Example)
A

Safety FlexLine
5
2.6 Personal safety
2.7 Warnings and cautions
2.7.1 General
When it is required to open the instrument in an explosive hazardous environment.
Warning!
In hazardous areas it is compulsory to use personal protection and
safety gear. This can be:
• Safety helmet, fire-resistive overall, safety shoes, safety glasses,
working gloves, LEL-meter.
Pay attention to the kind of product in the tank. If there is any danger
for your health, wear a gas mask and take all necessary precautions.
Warning!
Take appropriate precautions when chemical or toxic product vapors
are present (compressed air, chemical protection suit, detection
equipment).
NOTE
The emitted microwave energy is far below the accepted limits for
exposure of the human body. The antenna generates a maximum
radiation of 0.1 mW/cm2.
Warning!
Make sure that all power to the device is switched off before you open
the covers of the device. Failure to do so may cause danger to
persons or damage the equipment. All covers of the device must be
closed before switching the power on again.
Warning!
Treat the flange surface of the cover and the housing with care.
Keep the flange surface free of dirt.
The O-ring must be present and undamaged.

FlexLine Safety
6
Too ls
Working environment
Required skills
Warning!
Use non-sparking tools and explosion-proof testers. Use suitable
explosion-proof tools (e.g. testing devices)!
Warning!
Avoid generation of static electricity. Make sure that no explosive gas
mixtures build up in the working area.
Warning!
The technician must have technical skills to be able to safely install the
equipment. The technician also must be trained to work in accordance
with the national requirements for electrical equipment in hazardous
areas.

Safety FlexLine
7
2.8 Electrical
2.8.1 IEC safety standards
• The entire electrical installation must be in accordance with the International
Standard EN IEC 60079-14 for electrical equipment in hazardous areas or with
NEC (NFPA70) requirements.
• The stopping plugs, cable glands and reducers must be installed in accordance
with appropriate IP requirements
• Use explosion proof (Ex-d) compound barrier glands (due >2 litres IIB) in case of
use without SmartConn (Ex-e junction box).
• Use increased safe (Ex-e) cable glands in case a SmartConn box is used.
• Improper installation of cable glands, conduits or stopping plugs will invalidate the
Ex approval of this device.
2.8.2 Grounding
2.9 Accordance to regulations
2.9.1 Device without SmartConn
Type of protection:
ATEX / IEC Ex / CSA
Certificate numbers:
SmartRadar FlexLine: KEMA 07ATEX0010X and IECEX KEM 07.0003 X.
SmartView: KEMA 07ATEX0011X and IECEX KEM 07.0004 X.
SmartConn: KEMA 07ATEX0093 and IECEX KEM 07.0031.
Without SmartView: Ex d [ia] T6 Ta: -40 °C - +65 °C.
With SmartView: Ex d [ia] ia T4 Ta: -25 °C - +65 °C.
Warning!
Make sure the housing of the device is properly connected to the
ground reference! Make sure that the electrical resistance of the
ground connection is below the maximum of prescribed by local
requirements!
Tabla de contenidos
Otros manuales de Instrumento de medición de enraf
Manuales populares de Instrumento de medición de otras marcas

Endress+Hauser
Endress+Hauser Proline Promag 50 Especificaciones técnicas

Siemens
Siemens SITRANS F Coriolis FCT030 Manual de lista de piezas

KLINGER
KLINGER CMF V Series Manual de usuario

EXFO
EXFO FTB-2 Manual de operación y mantenimiento

Keysight
Keysight M8290A Manual de usuario

ADTEK
ADTEK MW-5 Manual de usuario














