Enel X JuicePump Guía

175 kW DC
RT
www.enelx.com
Phone: +1-844-584-2329
User Unit Installation Manual
TRI125-175-S (USA)


www.enelx.com
Phone: +1-844-584-2329
TRI125.INS.036.3
Important safety instructions................................................................................................1
Packaging, handling, & receipt...............................................................................................4
Servicing distance............................................................................................6
Cable range......................................................................................................6
Baseplate dimensions............................................................................................................7
Installation requirements & equipment.................................................................................8
Unpacking..............................................................................................................................9
Installation............................................................................................................................10
Wiring and commissioning...................................................................................................12
Ethernet port access............................................................................................................14
Closing checklist...................................................................................................................16
Contents

1www.enelx.com
Phone: +1-844-584-2329
TRI125.INS.036.3
Important safety instructions
This manual contains important
instructions for the JuicePump electric
vehicle fast charger.
Read the installation and operating
instructions before installing and
commissioning the equipment.
These instructions must be followed
during installation, operation, and
maintenance of the unit.
CAUTION
The JuicePump fast charger user unit
must be installed and serviced only by
To achieve EMC compliance, the chassis
of the JuicePump user unit must be
bonded to Earth locally at the charger.
Grounding instructions
This unit must be connected to a
grounded, metal, permanent wiring
system. An equipment-grounding conduc-
tor must be run with circuit
conductors and connected to
equipment-grounding terminal or lead on
the electric vehicle charger.
Connections to the battery charger shall
comply with all local codes and
ordinances.
Observe all pertinent national,
regional, and local safety laws and
regulations when installing and
commissioning the JuicePump fast
charger.
Identifying symbols
CRITICAL
CAUTION
RISK OF ELECTRIC SHOCK
Equipment Grounding
Conductor Symbol
ø Phase Symbol
Alternating Current Supply
Symbol
Wiring
Power and Protective Earth (PE) Conduc-
section), V90 class, rated to operate at
90°C.
The manufacturer recommends the use of
copper cables. Refer to the TRI125.
INS.016 JuicePump RT 175-S Piping and
Cabling-
tions.
Take care to observe local regulations
same conduit, including the ethernet
link if used. In general, all conductors
occupying the same conduit shall have
an insulation rating equal to at least the
conductor within the conduit.
SAVE THESE INSTRUCTIONS

2www.enelx.com
Phone: +1-844-584-2329
TRI125.INS.036.3
Warning
commercial garage (repair facility) or
closer than 6,096 mm / 20 feet of an
outdoor motor fuel dispensing device.
Input
190A
1ø, 240 VAC
3A
connected to a circuit provided with
appropriate over-current protection in
accordance with the National Electrical
Code, ANSI/NFPA 70.
Tightening torque
Wiring terminals
30 Nm / 22 lb-ft
Service hatch
2 Nm / 17.7 lb-in
Weather rating
NEMA Type 3R
Usage limitations
cable assemblies shall not be used
in addition to the cable assembly for
the connection of the vehicle to the
charger.
Adaptors shall not be used to
connect a vehicle connector to a
vehicle inlet.
Important safety instructions
SAVE THESE INSTRUCTIONS

3www.enelx.com
Phone: +1-844-584-2329
TRI125.INS.036.3
Important safety instructions
FCC Notice
Information to the User
(FCC Part 15.105)
Class A product:
NOTE:
This equipment has been tested and
found to comply with the limits for a
of the FCC rules. These limits are
designed to provide reasonable protection
against harmful interference when the
equipment is operated in a commercial
environment. This equipment generates,
uses, and can radiate radio frequency
energy and, if not installed and used in
accordance with the instruction manual,
may cause harmful interference to
radio communications. Operation of this
equipment in a residential area is likely to
cause harmful interference in which case
the user will be required to correct the
Modication warning
(FCC Part 15.21)
-
turer could void the user’s authority to
operate this equipment.
SAVE THESE INSTRUCTIONS

4www.enelx.com
Phone: +1-844-584-2329
TRI125.INS.036.3
Read these instructions carefully to
become familiar with the JuicePump user
unit packaging and handling procedures
prior to unpacking and installation.
In all cases, the JuicePump user unit
must be transported to the installation
site in its original packaging and only
unpacked at the installation site.
Installation, commissioning, and servicing
of the JuicePump user unit should only be
Materials
The JuicePump user unit is transported in
a reinforced cardboard crate.
Please respect the environment and
recycle/reuse the materials.
Storage
Store in the original packaging in a
Store in a dry location, protected from
the weather, i.e., in warehouse
conditions.
Storage temperature:
Handling
Only lift the JuicePump user unit pack-
forklift or pallet jack or with lifting straps
and engine hoist, forklift, or crane. Check
the weight on the delivery documents and
ensure the lifting apparatus used is
compatible.
Receipt
Check that the crate packaging is in
good condition and that the JuicePump
user unit is not damaged.
If there are any problems noted, make a
formal complaint to the carrier and notify
your supplier.
Packed crate weight
Crate size
Packaging, handling, & receipt

www.enelx.com
Phone: +1-844-584-2329
TRI125.INS.036.3
Site survey
installation site to determine the
and weight of the JuicePump user unit in
accordance with local regulations.
The JuicePump user unit is best
installed following the recommended site
Ground xing
fasteners.
Fasteners are not supplied, as the type
required depends on the foundation used
and must be chosen by the installer
accordingly.
user unit securely to the foundation
through the baseplate in accordance with
the “Baseplate dimensions” section.
Note: Keep the plastic inserts from the
bolts for use in the baseplate holes.
Conduit requirement
Ø 110 mm OD conduit.
When preparing the foundation,
ensure that conduit and wiring terminates
above ground according to the document
TRI125.INS.016 JuicePump RT 175-S Pip-
ing and Cabling.
Foundation requirements
have the appropriate density for the
weight of the JuicePump user unit.
foundation and level of the JuicePump
Communications
between the IPU and UU. If the UU and
(default).
4G network capability.
Category 6a STP Ethernet cable required
with a minimum length from the founda-
tion surface.
Fiber Optic Cable: OM3 Multi Mode 2 Core
For detailed wiring instructions, see
-
ing and Cabling
.

6www.enelx.com
Phone: +1-844-584-2329
TRI125.INS.036.3
Servicing distance
inches from the front and rear of the
JuicePump user unit is required to open
the front panel for servicing, as shown in
the image below.
Cable range
4300
Figure 2. Cable range
4300 mm / 169.291 inches

7www.enelx.com
Phone: +1-844-584-2329
TRI125.INS.036.3
Baseplate dimensions
Note: Do not scale. All dimensions shown in millimeters (mm)/inches (in).
A mounting stencil may be supplied by the manufacturer at customer re-
quest.
300 / 11.811
36 / 1.417
236 / 9.291
670 / 26.377
300 / 11.811
Otros manuales para JuicePump
4
Tabla de contenidos
Otros manuales de Accesorios para automóviles de Enel X