SET SET
C.s.lo.= Control set point lower limit.(for
selected output)
Adjustable between 0 and C.s.Hi.
C.s.Hi.= Control setpoint upper limit.(for
selected output)
Adjustable between and Upper scaleC.s.Lo.
a2.s.l= Alarm2 set value lower limit.
Adjustable between 0 and A2.S.H
parameter value.
a2.s.H= Alarm2 set value upper limit.
Adjustable between
parameter value and upper scale
value.
A2.S.L
a2.Hy=
.
Hysteresis of the Alarm2
output
A2.st. = The state of Alarm2 output.
If A2 output is above the set
value. (on)
Hi=
lo= If A2 output is above the set
A2.Er. =
2 output is probe failure (on).
State of Alarm2 output in the
case of sensor failure.
= Aon
A2.tp
indE.
= Function of Alarm type.
Four kinds of functions can be
selected.
= alarm
(Independent)
= Deviation
= Band alarm (Band)
2
Independdnt
dE.
bAnd
inp.t.
c.cn.
=
= J type , = K type = T
type =S type , = R type
thermocouple selection.
This parameter varies when changing
Input type selection.
FE.cn. nc.nA.
p10.r. P13.r.
Unit = The temperature unit.
C°= °C, = °F
(This parameter varies when
°F
C.o.sE = Control output selection
C-A2
SSR
= C/A2 (Relay) output selection
= SSR output selection
F.kE.C. = Function key setting parameter
nonE
manu.
= Function key is off.
= The function key with 2.set value is used.
= Manual mode can be achieved with the
function key.
= Only the temperature display mode is
C2.S.A.
dSP.o.
C. Pb
C. Pb
=
%0 %100
= %0 On-Off
Proportional band.(for selected
output)
Adjustable between .0 and .0.
.0, control is selected.
C. ti
C. ti
C. Pb
=
=
Integral time.(for selected output)
Adjustable between 0 and 100.0 minutes.
0.0,integral impact is disable.
parameter is different from “0”,this
C.Hys = Hysteresis of the output.(for
selected output)
Adjustable between 1 and 50 °C.
C. td
C. td
=
=
Derivative time.(for selected output)
Asjustable between 0.00 and 25.00 minutes.
0.0, derivative time is disable.
parameter is different from”0”,thisC. Pb
C. Ct.
C. Pb
= Period time.(for selected output)
Adjustable between 1 and 250 second.
parameter is different is different
C.p.st = The ratio of output power at the
setpoint.Adjustable between %0 and %100.
C.E.P.s.= The percentage of faulty sensor
selected output power.Adjustable between
%0 and %100.
C.typ. = Control output type
C.typ.
typ
=
=
HEAt
CooL
means heatign control.
means cooling control.C. .
While the parameter names appear,if and
keys are pressed together, returns to the program
mode.
S.Cod =
.
Security menu access
code
It should be 2011.
Cosc. CoN.o.
nonE
P.yEs
=
=
=
Parameters of
menu security access level code.
Invisible.
Modification can be done.
m.SEt. =
This parameter allows manual adjustment of the output
power when the manual output selection.
The percentage of manual output parameter.
Adjustable between %0 and %100.
If parameter is different
from C-A2,this parameter is seen.
co.SE
a.2.sc. al2.o.
nonE
P.yEs
=
=
=
Parameters of
menu security access level code.
Invisible.
Modification can be done.
Co.sc. Conf.
nonE
P.yEs
P. no
=
=
=
Parameters of
menu security access level code.
Invisible.
Modification can be done.
= Only visible.
S.t.Sc. =
men
=
Parameters of
u security access level code.
Invisible.
S.tun.
nonE
Co.sc. Conf.
no
yEs
=
m
=
=
Parameters of
enu security access level code.
Parameter settings are not
change.
Parameter setting will be
C.s.Lo.
C.s.Hi.
C. pb
C. ti
C. td
C.p.st
C.Hys
C. Ct.
C.typ
s.s.t.s.
C.E.p.s.
Con.o. AL2.o. ConF. S.tun. SEcu.
S.Cod.
Co.sc.
m.SEt.
a.2.sc.
Cn.sc.
S.t.sc.
dEF.P.
inp.t.
Unit
fltr.
C.o.sE
offs.
s.t.Co.
F.k.E.C.
A2.S.L
A2.S.H
A2.HY
A2.tP
A2.St.
A2.Er.
SET SET SET SET SET
F
Programming mode
This parameter indicates the time to reach set point
value when the device is first enegised.
Adjustable between 0 and 250 minutes.
If 0 is selected, soft start feature will be enable and the
device reaches set point value quickly.
Pb = 0, so start feature will be disable.Setting ft
Sst.S =Sofy starter timer set value
fLtr.= Coefficient of digital filter.
Filter for display value.
Adjustable between 1 and . If this parameter is 1,
digital filter runs most quick. If the parameter is ,
the filter run most slow. The value of parameter should
be increased in interference.
200
200
oFfS. = Offset value.
Offset value is added to the measurement value.
Adjusted between -100 and +100°C.The normal value is 0.
St.Cu = Self tune control parameter.
If both keys are pressed ,
message is displayed on the screen
and self tune process is started
automatically.
If both keys are pressed,
message is displayed on the screen
and self tune process is stopped.
yes
no
Selt tune begins when the measurement,
and measurement value
are shown alternately.Self tune process
completed automatically after the
parameter is done no and is entered to the
working mode. Self tune process begin when
the measured temperature is expected fall
below 90% of the set value the display shows
message alternately.Expected to fall
below the temperature set point 60% evolved
and then self tune process starts automatically.
If asked to abort the self tune process,
parameter is done and key is
pressed.
PIdt.
te.HI
St.Co
message
stco
no
SET
If key is pressed while holding key, the programming mode is enabled.
SET
F
Entering from the programming mode to the run mode:
If no key is pressed within 20 seconds during programming mode, the data is stored automatically and the run mode is entered.
Alternatively, the same function occurs first pressing key and key is pressing programming mode is entered.Then and keys are pressing
together,data is recorded and running mode is entered.
Modification Of Parameter Diagram
When holding key, the value of parameter flashes and using
keys the requested value can be adjusted.
If key is pressed and held 0.6 seconds, the value of the selected
parameter changes rapidly. If waited enough,the value increases 100 at each
step. After 1 second following the release of the key, initial condition is
returned.The same procedure is valid for the decrement key.
Chys 656
SET SET SET
SET
C.s.lO.inp.t.
A2.s.l Co.sc.
C1.sE.
C.s.Hi.Unit
A2.s.H A2.Sc.
C2.SE.
C. PB Fltr.
A2Hy. Cn.Sc.
A2.SE.
C.HyS C.o.SE.
A2.tp S.t.Sc.
C. ti offs.
a2.st. dEf.P.
C. td f.k.E.C.
a2.Er.
a2.Er.
C. Ct.m.sEt.
C.P.St.
C.EP.S.
S.s.t.S.
C.typ.
TC input TC input TC input
TC input TC input
Pt100 input Pt100 input Pt100 input
Pt100 input Pt100 input
0
FE.cn.
0
025
2
2C-A2
indE P.yEs
P.yEs
400
P.yEs
400
P.yEs
500
4.0 0
Hi no
1.00 nonE
on
no
20 50
0
0
0
HEat
-200 Pt.
-200
600 °C
600
DEFAULT PARAMETERS
Set parameters Control output
parameters
Alarm2 output
parameters
Configuration
parameters
Self tune
parameters
Security
parameters
SET
SET
2/4 ET -E2011