emmeti Merriott PPED Series Manual de usuario

Electric Range (Digital Control E-D)
Installation, operating
& instruction manual
Panel Radiators
PLEASE LEAVE THIS MANUAL WITH THE END USER
Class I - V - Hz

. Product Information
. Safety Information
. Waste Disposal According to The WEEE Directive (//EU)
. General Information
. Installation
. Operation
. General
. Heating
. Advanced Mode
. Stand-alone Radiator
. Radiator Connected to a Central Control
. Radiator Connected to a Unisenza Plus Gateway
. Radiator Connected to a Touch Programmer
. Parameter Menu
. Maintenance, Repair & Disposal
. Warranty
. Technical Characteristics
. Eco Directive Characteristics
Contents

3Electric Range (Digital Control E-D)
Min.
200mm
Min.
100mm
Min. 100mm
Min. 100mm
Min. 100mm
Zone Zone
Zone
Zone
OUTSIDEZONES
m
.m
.m
.m
Step
A
Step
Safety Clip-on Brackets
Product Information
.

Electric Range (Digital Control E-D)4
Height
(mm)
C
D
Length
(mm)
A
B
B
C
A
D
L
B
C
H
Cable Hook Assembly
Product Information (cont...)
.

Electric Range (Digital Control E-D) 5
A
B
Switched Fused Spur
Terminal
Block
Wire Colours
BR = Brown
BK = Black (Neutral)
BL = Blue
G/Y = Green/Yellow
Stand-alone Operation
Connected to a TouchProgrammer
N
L
N
LOAD L
LOAD
N
L
N
LOAD L
LOAD
230V 50Hz SUPPLY
NEUTRAL
LIVE EARTH
G/Y
BRBL
BL BR
G/Y
BK
Switched Fused Spur
Electric Radiator Cable
Terminal
Block
Mark switched live
pilot wire with brown
insulation tape
Mark switched live
pilot wire with brown
insulation tape EARTH
BK
BK
Switched Fused Spur
PILOT WIRE FROM PROGRAMMER
(switched live)
G/Y
Wire Colours
BR = Brown
BK = Black
BL = Blue
G/Y = Green/Yellow
Product Information (cont...)
.

Electric Range (Digital Control E-D)6
C
D
BRBLG/Y
Zone 2 Zone 1
G/YBLBR
BK
Zone 4 Zone 3
Live
Neutral
BR
BL
G/Y
G/Y
BLBR
BK
G/Y
BLBR
BK
G/Y
BLBR
BK
NL
CH4 CH3 CH2 CH1
Touch4
BRBLG/Y
Other products in
Zone 1
Other products in
Zone 2
Other products in
Zone 3
Other products in
Zone 4
ON
ON
ON
ON
ON
ON
ON
ON
F
U
S
E
ON
F
U
S
E
F
U
S
E
F
U
S
E
F
U
S
E
F
U
S
E
F
U
S
E
F
U
S
E
F
U
S
E
Wire Colours
BR = Brown
BK = Black
BL = Blue
G/Y = Green/Yellow
A suitable means of local isolation of the radiator from both the electrical supply and the pilot wire signal must be provided.
The fused spurs must be clearly marked to indicate that two sources of electrical supply may be present. The outputs from
the programmer are switched Live.
Product Information (cont...)
.
NO
A
B
C

Electric Range (Digital Control E-D) 7
Product Information (cont...)
.
=
=

Electric Range (Digital Control E-D)8
Product Information (cont...)
.
XOK
8s 1s

Electric Range (Digital Control E-D) 9
Due to the safety standard
EN , the text below is
obligatory for all electric products,
not only radiators.
This appliance can be used by
children aged from years and above
and persons with reduced physical,
sensory or mental capabilities or
lack of experience and knowledge
if they have been given supervision
or instruction concerning use of
the appliance in a safe way and
understand the hazards involved.
Children shall not play with the
appliance. Cleaning and user
maintenance shall not be made by
children unless they are older than
and supervised. Keep the appliance
and its cord out of reach of children
aged less than years. Children
of less than years should be
kept away from the unit unless
continuously supervised. Children
aged from years and less than
years shall only switch on/off the
appliance provided that it has been
placed or installed in its normal
operating position and they have
been given supervision or instruction
concerning use of the appliance in a
safe way and understand the hazards
involved. Children aged from years
and less than years shall not plug in,
regulate and clean the appliance or
perform user maintenance.
CAUTION
Some parts of this product can become very hot and cause burns. Particular
attention has to be given where children and vulnerable people are present.
In order to avoid overheating, do not cover the radiator. “Do not cover”
means that the radiator must not be used for drying clothes, for
example, by placing them directly on the radiator.
Safety Information
.
Waste disposal according to the WEEE directive
//EU. The symbol on the product
label indicates that the product may not be
handled as domestic waste, but must be sorted
separately. When it reaches the end of its useful
life, it shall be returned to a collection facility for electrical and
electronic products. By returning the product, you will help to
prevent possible negative effects on the environment and health
to which the product can contribute if it is disposed of as ordinary
domestic waste. For information about recycling and collection
facilities, you should contact your local authority/municipality
or refuse collection service or the business from which you
purchased the product. Applicable to countries where this
Directive has been adopted.
WEEE NO: WEE/HDVZ
. Waste Disposal According to
The WEEE Directive (//EU)

Electric Range (Digital Control E-D)10
>This appliance is a sealed electric radiator designed for
fixed wall-mounted installation.
>This appliance conforms to the standards EN
and EN .
>The appliance is insulation class I and has electrical
protection level IP.
>This appliance complies with European Directive
//EU (CE Marking on all appliances).
>The product is supplied complete with a connection cable
and wall brackets.
Positioning
>The radiator must be positioned horizontally in order for it
to function correctly.
>The radiator must be positioned according to the applicable
standards.The minimum distances as specified in picture
should be carefully observed.
>The radiator may be positioned inside zone (picture ),
insofar as no operating controls (button, switches, etc …)
are in reach of persons in the bath or under the shower.
>The radiator must be fixed to the wall using the wall
brackets supplied.
>The radiator must not be located underneath an
electrical socket.
Fixing
>Mark out the distance between the brackets and the positions
of the screw holes as shown in the table in picture B.
>Ensure that the safety clips are used, as shown in picture A.
NOTE: mm long products are supplied with extra brackets
as a rd bracket must be fitted in the middle of the product.
>For the correct installation of radiators it is essential that
the fixing of the radiator is carried out in such a way that it is
suitable for intended use AND predictable misuse. A number
of elements need to be taken into consideration including the
fixing method used to secure the radiator to the wall, the type
and condition of the wall itself, and any additional potential
forces or weights, prior to finalising installation.
>The fixing materials provided are only intended for
installation on walls made of solid wood, bricks, concrete or
on timber-frame stud walls where the fixing is directly into
the timber. All walls being considered should have no more
than a maximum of mm wall finishing. For walls made of
other materials, for example hollow bricks; please consult
your installer and/or specialist supplier.
In all cases it is strongly recommended that a suitably
qualified professional installer or similar tradesperson
carries out the installation.
Connection
>The electrical installation must comply with local or
national regulations.
>The radiator should be connected by a suitable and
qualified electrician. Please refer to the wiring diagrams in
pictures A, or B and C for the connection of the radiator.
>The radiator must be connected to the electrical supply,
using a switched fused spur with mm separation on all poles.
>The radiator must be connected to the electrical supply
using the supply cable fitted to the unit.
>If the radiator is installed in a bathroom or shower room, it
must be protected with a residual current device (RCD) with
a rated residual current not exceeding mA.
>The radiator is equipped with a non-resettable overheat
protection that trips off if the radiator overheats. If the
radiator is removed from the wall brackets, even for a short
time, it must without exception be switched off, see picture
D.This may even trip the non-resettable overheat protection.
If the overheat protection trips, its thermal fuse must be
replaced; contact your supplier.
>The On/Off button is located at the bottom of the control side
of the radiator (C, picture ). The radiator should only be
switched “on” when it is correctly installed and secured to the
wall brackets (picture C). When the radiator is switched “on”,
the LCD screen will illuminate and all segments will be displayed
for a few seconds, then disappear, before displaying the
software version. The “Comfort” or previously selected
operating mode screen will appear. The backlight will switch
off after a further seconds.
>Display (A, picture )
. Programme information bar or “behaviour” indicator.
. Day of week indicator.
. Cloud icon (with Unisenza PLUS Gateway).
. “RF connection” indicator (with Unisenza PLUS Gateway).
. Adaptive Start indicator.
Installation
.
Operation
.
General Information
.
Este manual sirve para los siguientes modelos
2
Tabla de contenidos
Otros manuales de Calentador de emmeti
Manuales populares de Calentador de otras marcas

Empire Heating Systems
Empire Heating Systems WCC65 Manual de usuario

Wetekom
Wetekom 92 86 43 Manual de usuario

Desa
Desa SPC170-F Manual de usuario

Watlow
Watlow Watrod Electric Tubular Heaters Manual de usuario

Haverland
Haverland ECO-DRY GPS Series Manual de lista de piezas

Stelpro
Stelpro ASILVC2060 Series Manual de usuario