Emerson Rosemount 3300 Series Manual de usuario

Quick Start Guide
00825-0100-4811, Rev JG
November 2022
Rosemount™ 3300 Level Transmitter
Guided Wave Radar

Contents
About this guide...........................................................................................................................3
Mount the transmitter head/probe.............................................................................................. 7
Set jumpers and switches...........................................................................................................17
Connect wiring and power up.....................................................................................................19
Configure...................................................................................................................................25
Environmental conditions.......................................................................................................... 32
Product certifications................................................................................................................. 33
Quick Start Guide November 2022
2 Rosemount 3300 Level Transmitter

1 About this guide
This start guide provides basic guidelines for the Rosemount 3300 Level
Transmitter. Refer to Rosemount 3300 Level Transmitter Reference Manual
for more instructions. The manual and this Quick Start Guide (QSG) are also
available electronically on Emerson.com/Rosemount.
1.1 Safety messages
WARNING
Failure to follow safe installation and servicing guidelines could result in
death or serious injury.
Ensure only qualified personnel perform installation or service.
Use the equipment only as specified in this Quick Start Guide and the
Reference Manual. Failure to do so may impair the protection provided by
the equipment.
Repair, e.g. substitution of components, etc. may jeopardize safety and is
under no circumstances allowed.
Flamepath joints are not for repair. Contact the manufacturer.
WARNING
Explosions could result in death or serious injury.
Verify that the operating environment of the transmitter is consistent with
the appropriate hazardous locations specifications. See Product
certifications in this Quick Start Guide.
Temperature restrictions apply for Explosion-proof versions. For limits, see
certificate-specific information in the Product certifications chapter in this
document.
In an explosion-proof/flameproof installation, do not remove the transmitter
covers when power is applied to the unit.
Before connecting a handheld communicator in an explosive atmosphere,
ensure the instruments are installed in accordance with intrinsically safe or
non-incendive field wiring practices.
November 2022 Quick Start Guide
Quick Start Guide 3

WARNING
Electrical shock could cause death or serious injury.
Avoid contact with the leads and terminals. High voltage that may be
present on leads can cause electrical shock.
Ensure the mains power to the transmitter is off and the lines to any other
external power source are disconnected or not powered while wiring the
transmitter.
WARNING
Process leaks could result in death or serious injury.
Ensure that the transmitter is handled carefully. If the process seal is
damaged, gas might escape from the tank.
To avoid process leaks, only use the O-ring designed to seal with the
corresponding flange adapter.
WARNING
Physical access
Unauthorized personnel may potentially cause significant damage to and/or
misconfiguration of end users’ equipment. This could be intentional or
unintentional and needs to be protected against.
Physical security is an important part of any security program and
fundamental to protecting your system. Restrict physical access by
unauthorized personnel to protect end users’ assets. This is true for all
systems used within the facility.
1.2 Equipment category
The electronics enclosures are category 2G or 2D equipment. The probes
not covered with plastic and not made of titanium, are category 1G or 1D.
The plastic covered probes or probes made of titanium, are only category 1G
equipment.
Quick Start Guide November 2022
4 Rosemount 3300 Level Transmitter

Figure 1-1: Equipment Category
Category 2D
Category 1D
Applicable marking:
Probes according to table
Ex tb [ia Da] IIIC T85 °C…T450 °C Db
II 1/2 D Ex ia IIIC T20085 °C…T200450 °C Da /
Category 2G
Category 1G
All probes possible
II 1/2 G Ex ia IIC T6…T1 Ga /
Ex db [ia Ga] IIC T6…T1 Gb
Applicable marking:
Category 2D
Category 2D
Probes according to Table 1-1
Applicable marking:
II 2 D Ex tb IIIC T85 °C…T135 °C Db
Probes with non-conducting surfaces and light metals
Probes covered with plastic and/or with plastic discs may generate an
ignition- capable level of electrostatic charge under certain extreme
conditions. Therefore, when the probe is used in a potentially explosive
atmosphere, appropriate measures must be taken to prevent electrostatic
discharge. These probes are not allowed in dust classified areas.
The following probes do not contain plastic or PTFE material, and are
allowed to be placed in a Dust classified area:
November 2022 Quick Start Guide
Quick Start Guide 5

Table 1-1: Probes Containing no Plastic or PTFE Material
Code Material of construction: Process connection/Probe
1 316L SST (EN 1.4404)
2 Alloy C-276 (UNS N10276) plate design if flanged version
3 Alloy 400 (UNS N04400) plate design if flanged version
5 Titanium Gr-1 and Gr-2
9 Duplex 2205 (EN 1.4462/UNS S31803) (plate design if flanged
version)
L Alloy 625 (UNS N06625)
M Alloy 400 (UNS N04400)
H Alloy C-276 (UNS N10276)
D Duplex 2205 (EN 1.4462/UNS S31803)
The Material of Construction Code can be found in the ninth character
position of the transmitter model code (for example 330xxxxx1xxxxxxxx).
Probes and flanges containing >7.5 percent magnesium or zirconium are not
allowed in explosive dust atmosphere. Contact your Emerson sales
representative for more information.
Probes and flanges containing light metals
When used in category 1/2G installations, probes and flanges containing
titanium or zirconium must be mounted in such a way that sparks from
impact or friction between these parts and steel cannot occur.
Separation element (EPL Ga/Gb, Da/Db)
The materials of the separation element are > 3 mm stainless steel and a 22
mm bushing filled with 2-part epoxy. The epoxy has a continuous operating
temperature of -55 °C ≤ COT ≤ 130 °C. Under normal operation the
separation element is not pressurized or in contact with the process media.
Quick Start Guide November 2022
6 Rosemount 3300 Level Transmitter

2 Mount the transmitter head/probe
2.1 Tank connection with flange
Prerequisites
Note
PTFE covered probes must be handled carefully to prevent damage to the
coating.
Procedure
1. Place a suitable gasket on top of the tank flange.
Note
Gasket should not be used for PTFE covered probe with protective
plate.
$
A. PTFE covered probe with protective plate
2. Lower the transmitter and probe with flange into the tank.
November 2022 Quick Start Guide
Quick Start Guide 7

3. Tighten bolts and nuts with sufficient torque for the flange and
gasket choice.
4. Loosen the nut that connects the transmitter head to the probe
slightly.
60 mm
5. Rotate the transmitter housing so the cable entries/display face the
desired direction.
Quick Start Guide November 2022
8 Rosemount 3300 Level Transmitter

6. Tighten the nut.
60 mm
Torque 30 ft-lb (40 Nm)
2.2 Threaded tank connection
Prerequisites
Note
PTFE covered probes must be handled carefully to prevent damage to the
coating.
Procedure
1. For adapters with BSPP (G) threads, place a suitable gasket on top of
the tank flange.
2. For adapters with NPT threads, use anti-seize paste or PTFE tape
according to your site procedures.
November 2022 Quick Start Guide
Quick Start Guide 9

3. Lower the transmitter and probe into the tank.
4. Loosen the nut that connects the transmitter head to the probe
slightly.
60 mm
5. Screw the adapter into the process connection.
52 mm / 60 mm
Quick Start Guide November 2022
10 Rosemount 3300 Level Transmitter
Otros manuales para Rosemount 3300 Series
5
Tabla de contenidos
Otros manuales de Radar de Emerson

Emerson
Emerson ROSEMOUNT 5300 Manual de usuario

Emerson
Emerson Rosemount 3308A Manual de usuario

Emerson
Emerson Rosemount 3308A Manual de usuario

Emerson
Emerson Rosemount 5300 Series Manual de usuario

Emerson
Emerson 3308A Rosemount 3308 Series Manual de usuario

Emerson
Emerson Rosemount 5600 Series Manual de usuario
Manuales populares de Radar de otras marcas

SAW D2L
SAW D2L Valentine One Gen2 Manual de usuario

Raymarine
Raymarine Raytheon R20X Manual de usuario

Simrad
Simrad CA34 Manual de usuario

Endress+Hauser
Endress+Hauser Micropilot FMR67B Especificaciones técnicas

Endress+Hauser
Endress+Hauser Levelflex M FMP45 Manual de usuario

ECHOMAX
ECHOMAX Active-X-Band Manual de usuario