Emco Tech Venus Manual de usuario

Importer
Owner's Manual
for your new
Emco Tech Venus
Water Ionizer
Warning: Incorrect installation and/or operation could void your valuable warranty.
Please protect your investment! READ THIS MANUAL CAREFULLY
www.royalwater.com

CONGRATULATIONS ON YOUR NEW PURCHASE!
1 2
You have just purchased the finest, most advanced home water system in the world!
Your new ionizer is designed to provide you with many years of healthy, "functional" water.
There are many specific uses and benefits of this amazing water, so read this manual carefully to learn
how to get both optimum performance out of your ionizer and to protect your investment.
Your new Emco Tech Venus produces filtered alkaline, ionized water.
Just exactly what is that? Your ionizer employs computer accurate and selectable magnetic energy
to perform electrolysis through patented platinum bonded titanium electrodes inside a water cell.
Inside this advanced cell, the magnetic energy separates the water into an alkaline (high pH) and
acid (low pH) stream without using any chemicals.
Ionizing the water in this way re-structures the molecules and reduces their cluster size, binds extra
oxygen molecules, and concentrates ionized, absorbable and beneficial minerals like Calcium,
Magnesium and Potassium.
Your new Emco Tech Venus also produces Acidic water. This type of water is lower than neutral
or pH7, and has many excellent uses. You will now have the convenience and benefits of water
that "functions" in many ways that ordinary tap, filtered or bottled water cannot.
Lets take a tour of your new Venus!
Description of control panel features
Accessories
Installation procedure
Operation
Performance and measuring pH
How to replace your filter
Some uses for alkaline and acidic water
About your biostone filter
Trouble shooting guide
Product specifications
TABLE OF CONTENTS
03-06
07-08
09-10
11
12
13-14
15-16
17-18
19-20
21-22
23-24
25
Important safety warnings and precautions

3 4
ELECTRICAL PRECAUTIONS AND SAFEGUARDS
※WARNING: Please read these pages carefully.
They contain very important information to keep YOU and your new ionizer safe!
When using your ionizer, especially when children are present, basic safety precautions should always
be followed, including the following:
IMPORTANT SAFETY WARNINGS
AND PRECAUTIONS
NEVER attempt to repair or service
the unit yourself.
Attempting to do so will void your
valuable warranty!
Contact your dealer to arrange
service or repair.
If your ionizer becomes submerged in water,
unplug the power cord from the wall before
removing the ionizer from the water.
Failure to do so may cause electric shock!
NEVER touch the power cord or
plug with wet hands
- this may result in electric shock!
Installation Precautions
Protect your ionizer from freezing
temperatures.
Protect your ionizer from direct
sunlight.
Do not put anything heavy on top of your ionizer.
Do not install your ionizer on an unstable or soft
surface.
Install only on a hard and level surface.
Do not wash your ionizer by immersion or by pouring
water over the main body;
always unplug your ionizer while cleaning the casing.
Clean with a damp sponge or cloth.
Ensure the power plug is firmly and properly inserted
into the outlet - failure to do so may result in
electric shock or fire!
Keep the power cord and your ionizer away from
hot surfaces or appliances -
failure to do so may result in electric shock or fire!
Do not operate your ionizer with a damaged power
cord or plug or insert into a faulty or worn outlet.
Never insert foreign objects into your ionizer.
Do not use your ionizer at voltages
other than specified
(AC 110V FOR USA).
Use a GFI outlet. Do not plug in your
ionizer where it will exceed the rating of
outlet or electric wiring. Failure to do so can result
in fire, injury and/or damage to yourself,
wiring or ionizer!
During Use
Do not run hot water through
your ionizer.
Do not clean by pouring water over
or spraying the ionizer.
Hot
Maintenance Precautions
Always unplug your ionizer when changing the fuse or cleaning your ionizer
- failure to do so may result in electric shock.
DO NOT use your ionizer with well water, water with
extreme hardness, high sediment or
TDS levels without first consulting your dealer.
Common Sense Precautions
Do not attempt to repair or service the unit yourself.
Contact your dealer.
Attempting to do so will void your valuable warranty!
Make sure to use your ionizer only with potable
water which is suitable for human consumption.
Do not close, bend, pinch, press
or otherwise obstruct
output ports or hoses.
If the appliance makes strange or
unusual noises or burning smells
are detected, unplug the power
cord immediately and contact
your dealer to arrange service.
Unplug your ionizer if you plan not to use it for an extended period or turn off
the main power switch on the back of the unit.
Filter replacement may be necessary.
If unused for more than two weeks remove the filter and store in a refrigerator
to inhibit bacteria or mold growth.
Filter replacement is necessary if unused for more than two weeks and the
filter is not refrigerated.

5 6
IMPORTANT SAFETY WARNINGS
AND PRECAUTIONS
GROUNDING INSTRUCTIONS -
This appliance must be grounded. In the event of a malfunction or breakdown, grounding will reduce
the risk of electric shock by providing a path of least resistance for electric current. This appliance is
equipped with a cord having an appliance grounding conductor and a grounding plug.
The plug must be plugged into an appropriate outlet that is installed and grounded in accordance with
all local codes and ordinances.
"WARNING - Improper connection of the appliance-grounding conductor can result in a risk of
electric shock. Check with a qualified electrician or service representative if you are in doubt whether
the appliance is properly grounded. Do not modify the plug provided with the appliance; if it will not fit
the outlet, have a proper outlet installed by a qualified technician.
a) The power-supply receptacle for the appliance shall be installed on a wall adjacent to the counter
space in which the appliance is to be installed;
b) Care shall be exercised, when the appliance is installed or removed, to reduce the likelihood of
damage to the supply cord.
pH Reagent Liquid Precautions
Do not expose the pH measuring reagent to extreme heat, flames or fire.
It is combustible.
Do not drink the pH reagent liquid, put it in the eyes or apply to the body.
- If the liquid is ingested, induce vomiting immediately and call
a doctor.
- If the liquid gets in the eyes, flush immediately and thoroughly
with cool water; call a doctor.
- If spilled or dropped on your body, wash if off immediately.
Make sure to keep the pH reagent liquid tightly closed and out of the reach of children.
Some helpful tips
For storing your alkaline water, glass or ceramic is best. Always try and
keep your stored water cool and away from direct sunlight.
You can use plastic, but only use lexan (number7) or poly bottles
(Nalgene type), preferably PBC free It is always best fresh out of
the machine and ideal if consumed on a day-to-day basis.
Do not store alkaline water in stainless steel, bronze or aluminum containers.
Save the box and Styrofoam your ionizer came packed in.
This will help if your ionizer needs to be transported at a later date.
Do not use an ionizer downstream of a sodium-based ion exchange softening
system or reverse osmosis system without first consulting with your dealer.
Safety Precautions
Warning
Caution
Property damage, serious injury or death may result if these instructions and precautions
are not observed.
Physical injuries or material damage may be caused if the instructions are not observed.
Do's and Dont's
DO NOT
DO
Do not disassemble it. Disconnect the power cord from
the wall outlet.
Do not touch it. Ground product for protection from
electric shock.
Precautions for use of Alkaline water - don't develop a "drinking" problem!
If you have never consumed alkaline water - start off with the lowest alkaline setting.
Let your body adjust slowly and naturally for 4-7 days. After this initial adjustment period, you
can gradually increase the alkalinity of the water.
Do not take medications with alkaline water. Take medications using the filtered water setting.
Consult with a physician before drinking alkaline water if you have:
- Chronic disease
- A dysfunctional liver or intestines
- Are currently under medical treatment
Do not drink alkaline water if you have achlorhydria.
Consult a physician before using acidic water if you have:
- Sensitive skin
- Allergies
Only use potable drinking water in your ionizer.
Poor water quality may have negative effects on your health and your ionizer! Most municipal
water sources will be fine in your ionizer.
Well water and water from smaller systems should be checked, and may require pre-filtering.
Your ionizer is not under warranty for any damage or required cleaning caused by hard water
deposits.
Please read these pages carefully. They contain very important information to keep YOU and your new ionizer safe!

7 8
LETS TAKE A TOUR OF YOUR NEW VENUS DESCRIPTION OF MAIN BODY
ⓐ Main Body
Easy to clean and durable plastic casing protects your ionizer.
ⓑ Control
Push Button Controls and function indicators (detailed on the next page).
ⓒ Flexible stainless steel drinking water spout
You will get your drinking water from this spout. It is flexible to accommodate
proper positioning.
ⓓ Filter Housing Door
You will open this door to access and change your filter.
ⓔ Flow Control Valve
This controls the flow rate of water through your ionizer. Tip: This adjustment has DIRECT
impact on the performance of your ionizer. SLOW FLOW = higher pH; FAST FLOW = lower pH
ⓕ Key-hole Slots For Wall Mounting
To save counter space you can mount your ionizer on the wall. Note: use suitable fasteners.
ⓖ Fuse Holder
Your ionizer comes equipped with a fuse to protect it in case of power surge or fluctuation.
ⓗ Main Power Switch
You will use this switch on the back to turn on and off the power supply to your ionizer.
ⓘ Back-Cover Panel.
ⓙ Acidic Water Outlet Port (On the bottom of your Venus)
This is labeled with a red sticker and is where the acidic stream will exit your ionizer.
ⓙ Tap Water Inlet Port (On the bottom of your Venus)
This is labeled with a blue sticker and is where the tap water will enter your ionizer.
ⓛ Power Cord.
This is your 110v AC power cord. Always use a GFI outlet in good working order.
ⓔ
ⓕ
ⓖ
ⓗ
ⓘ
ⓙ
ⓚ
ⓐ
ⓓ
ⓑ
ⓒ
ⓛ
ALKALINE
ALKALINE
ACIDIC
FILTERED
ACIDIC
FILTERED
Cleaning Check
Level

Cleaning Check
Alkaline
Alkaline
Acidic
Filtered
Acidic
Filtered
9 10
YOUR CONTROL PANEL DESCRIPTION OF CONTROL PANEL FEATURES
CONTROL PANEL
ⓐ
LED Filter Life Indicator
This LED indicator scale shows approximate filter life. When you first use your Venus the
lowest LED will be lit green. The LEDs lights will illuminate up the indicator scale as filter life
decreases. When the top LED illuminates Red it is time to order a new filter.
ⓑ Level Indicator
Shows Low, Medium and High settings.
ⓒ Alkaline Water Indicator
This illuminates when you have Alkaline Water selected
ⓓ Filtered Water Indicator
This illuminates when you have Filtered Water selected
ⓔ Acidic Water Indicator
This illuminates when Acidic Water is selected and/or when the machine is in cleaning mode.
Note: a tune will always plays when Acidic Water is selected or the ionizer is cleaning.
ⓕ Alkaline Water Button
Depressing this button selects Alkaline Water to come out of the Flexible Drinking Water Hose.
ⓖ Filtered Water Button
Depressing this button selects Filtered Water to come out of the Flexible Drinking Water Hose.
(Filtered Water is filtered with no change in the pH).
ⓗ Acidic Water Button
Depressing this button selects Acidic Water to come out of the Flexible Drinking Water Hose.
ⓘ Melody Button
Turns the sounds On or Off. Additionally, the volume can be adjusted on the button.
ⓙ Cleaning indicator
The cleaning mode will run for 10 seconds.
ⓚ Check indicator
When this light is lit the appliance needs to be serviced.
ⓐ
ⓑ
ⓒ
ⓓ
ⓔ
ⓕ
ⓖ
ⓗ
ⓘ
ⓙ
ⓚ
Level

11 12
ACCESSORIES INSTALLATION PROCEDURE
INSTALLATION PROCEDURE
Before installation, please check to ensure you have the following accessories.
Please note that the diverter and adapters fit onto the vast majority of standard faucets.
If you have a non-standard or custom faucet you may need to locate and purchase a
special adaptor - please consult with your dealer if necessary.
Install Kit (Divertor and adapters) Accessories
fuse / pH color chart
Reagent / Test tube or cup
Diverter / Hose clamps / Adapter
1. ATTACH THE DIVERTER TO YOUR TAP -
Remove the aerator from tap (pliers may be required), and attach diverter valve in its place
(see photo below). There are adapters supplied in case the diverter does not fit your tap.
DO NOT OVERTIGHTEN. If you have leaks at the diverter, use a few wraps of plumber's
Teflon tape which is available at any hardware store for a couple of dollars.
2. ATTACH THE WHITE HOSE TO THE TAP WATER INLET PORT -
Attach one end of the white hose to the gray port on the bottom of the ionizer
labeled "TAP WATER INLET" .
To attach the white hose, simply push it firmly into the opening on grey port.
3. ATTACH THE GRAY HOSE TO THE ACIDIC
WATER OUTLET PORT -
First, slide a squeeze clamp over the end of the hose.
Then attach the gray hose to the white plastic port
labeled ACIDIC WATER OUTLET on the bottom of the
ionizer.
Simply push the hose firmly over the white plastic port.
Squeeze the clamp and position it over the white port.
Ensure the opposite end runs into the sink.
4. POSITION YOUR IONIZER -
Ensure it is on a hard and level surface.
A wall mount can be done - there are keyhole slots
on the back for this.
5. ATTACH THE WHITE HOSE TO THE DIVERTER -
Remove the small compression nut on the back of
the diverter (opposite of the lever). Slide the nut over
the opposite end of the white hose you attached to the
TAP WATER INLET port with the threads positioned so
the nut will screw back onto the diverter.
Push the hose firmly onto the nipple.
Firmly screw the compression nut back on.
Do not over tighten.
6. CONNECT THE POWER CORD to an appropriate GFI outlet.
7. INSTALL FLEXIBLE STAINLESS STEEL SPOUT
- Screw this into the threaded port on the top of the ionizer.
Do not over tighten.
1/4" White hose
Grey hose
1/4" White hose

13 14
OPERATION OPERATION
1. POWER UP YOUR IONIZER.
- Depress the black power button located on the back of the ionizer to the
"ON" position.
- The black power button is ALWAYS left on. Your ionizer will "go to sleep" in
between uses and "wake up" when it detects water flow again.
- You will hear a single chime and the display panel will illuminate for 2-3 seconds.
- With the power on and the display panel dark, your ionizer is now in standby mode.
2. START WATER FLOW THROUGH YOUR IONIZER
A. Set the flow control Valve - This control is on the front of machine
and has an "ON" and "OFF" position. Try initially setting this half way
between "ON' and "OFF".
Important : This is one of the most critical features in controlling your
ionizer's performance.
This control WILL DIRECTLY impact the performance of your ionizer.
A slow flow will yield higher pH; a fast flow will yield lower pH.
B. Turn on your water faucet. Turn the lever to until you "divert" the water through your ionizer.
C. Get the feel for the difference in flow rates by adjusting FLOW CONTROL VALVE from a slow
trickle to the fastest flow. When you begin ionizing the water, start with it in the medium range
and adjust faster or slower as necessary to achieve optimum results.
3. TO SELECT ALKALINE WATER
A. Start Water Flow through your Venus.
Remember - The Venus cleans for 10 seconds after every 20 liters
B. To select an alkaline level simply depress the "ALKALINE" button to move to next
level until the desired level is achieved. The pH level indicator will change accordingly.
C. Note: Your Venus will always "remember" the last setting. For instance, if the previous
setting was Alkaline Level Medium, then it will go back to Medium when you start the
ionizer.
IMPORTANT NOTES:
-If you have never consumed alkaline water - do not use a setting higher than
LOW to begin with. Let your body adjust slowly and naturally for 4-7 days.
After this initial adjustment period, you may gradually increase the alkalinity of the water.
-pH levels will vary according to the minerals present in the source water and water
flow rate through your ionizer.
4. TO SELECT ACIDIC WATER
Note: Acidic water is for external use only. DO NOT DRINK.
1. With water running through the ionizer:
2. Depress the "ACIDIC" button. The Acidic Water Indicator will light and the pH Level
Indicator will move up and down the scale to indicate the selected level.
3. To select a different level, depress the "ACIDIC" button to move to next level until
the desired setting level is achieved. The orange symbol and number
will change accordingly.
5. TO SELECT "FILTERED" WATER
1. Start water flow through your ionizer.
2. Depress the "FILTERED" button. The Filtered Water Indicator will be illuminated.
"Filtered Water" runs through the Biostone filter, but does not receive any ionization.
The Filtered water comes out of the stainless steel spout.
6. HOW TO SHUT OFF THE WATER FLOW FROM YOUR IONIZER
Rotate the diverter lever until the water flow from the ionizer stops and reverts to the faucet.
The water will stop and the display panel will go dark indicating the ionizer is in standby
or "asleep".
ON OFF
After 20 liters of water have flowed through the JP107 units,
it will do an autoclean for 10 seconds.
For example, if the ionizer is used first for 15 liters and then is used for 5 liters,
upon the next use, the unit will do an auto clean for 10 seconds.
You are able to choose the autoclean setting.
Warning light comes on when 20 liters is reached and stays on until the unit is
next used and goes through its cleaning cycle. This red warning light is normal
and will go away after cleaning cycle is completed when unit is next used.
Notice

15 16
PERFORMANCE AND MEASURING pH
ALKALINE
WATER
ACIDIC
WATER
FILTERED
WATER
ALKALINE
WATER
ACIDIC
WATER
FILTERED
WATER
How to Measure pH
1) Fill one of the test tubes provided with about 1 inch of alkaline,
acidic or purified water.
2) Place 2-3 drops of the pH reagent into the tube and shake it. If the
reagent and water are not mixed well, the correct result may not be
achieved. Too many or too few drops will effect results, adding another
drop will make the color stronger.
3) The pH value is determined by matching the color with the pH color
chart provided.
4) Keep the pH indication reagent in a dark and cool place.
DO NOT expose to sunlight or heat.
THE PERFORMANCE OF YOUR IONIZER (VERY IMPORTANT INFORMATION!):
* There are three primary factors that control the performance of your ionizer:
1) The quality of your source water and its mineral content. We can not control this factor.
2) The voltage being applied to the minerals in the water. You control this by selecting the
Alkaline level on the control panel. The higher the setting the more voltage or power is
being applied to the water.
3) The flow rate of water through your ionizer. You control this with your faucet.
on the control panel. This determines how long the water is being processed.
With a fast flow your ionizer will produce lower pH, with a slow flow it will produce higher pH.
* Water quality and mineral content vary greatly in different localities.
Generally in "hard water" areas where mineral content is higher, your ionizer will easily reach
high levels of pH even with a faster flow. In "soft water" areas where mineral content is lower,
your ionizer may only reach the higher levels of pH with a slower flow.
* Learn to use the pH test kit and be sure to test your source water.
Also test the water produced at each alkaline setting at various flow rates.
* Do not drink the water that has been tested with the pH testing solution.

17 18
HOW TO REPLACEMENT THE FILTER
1
2
3
How to Replace the Filter
IMPORTANT! Stop water flow prior to filter replacement.
4
5
6
8
Check for leaks by running water through your ionizer before replacing the housing cover.
Flush out the GAC carbon dust.
- The water will initially come out discolored (light to charcoal gray) due to carbon dust in the
new filter. This is not harmful and is typical of all GAC filters.
Allow the water to flow for 2-3 minutes in the "Purified" mode and this will flush all the
carbon dust.
Replace the filter housing cover.
7
Reset the filter life indicator (2 method).
- Press the "Reset" button located at the top of the filter housing compartment for 2-3
seconds while in standby mode (water not running through the ionizer).
-
Press BOTH the Alkaline and Filtered buttons simultaneously until the LED lights
on the Filter Life Indicator resets.
When the top LED illuminates Red it is time to change your filter You will also want to
replace your filter if any of these situations occur:
- Severely reduced flow rate - slower than usual even with full flow on the control valve.
- Abnormally bad taste - usually due to a sudden change in quality of source water.
- A period of inactivity of over one month - for instance an extended vacation.
Open the filter housing cover.
-Push in on the plastic ridges in the center of the filter housing cover on the side while
pulling the door out and to the left. Swing door out and remove it.
Remove the expired filter.
-Taking hold of the filter securely with your right hand, press the
filter firmly down against the spring loaded mechanism to disengage
the top of the filter and then pull it toward you and up to remove it.
- The upper part of the filter is separated from housing by pressing
firmly down. Once you have engaged the spring loaded mechanism,
you can then easily remove the filter from the main body
by pulling it toward you.
Insert the new filter into the compartment.
-Remove the plastic caps covering both ends of
the new filter.
-Seat the large opening on the bottom of the filter
cartridge onto the base.
- Push the filter down and into the housing compartment
ensuring the opening at the top of the filter is seated
properly into the fitting at the top of the housing.
Reset
Button
#1) #2)
or
FILTER
COVER
FILTER
COVER
Otros manuales para Venus
1
Tabla de contenidos
Otros manuales de Sistema de filtración de agua de Emco Tech





















