EMCIS LN2-16 Instrucciones de operación

LISN (LN2-16)
User’s Operating Manual
Please read this manual before usage
Please keep this manual with the equipment
ELECTRO-MAGNETIC COMPATIBILITY INSTRUMENTS & SOLUTION
Emcis Bldg., Deokcheon-Ro 77, Manan-gu, Anyang-si, Gyeonggi-do, Korea
Tel : +82(0)31 444 0058 Fax : +82(0)31 465 0058
Website : www.emcis.co.kr e-mail : emcis@emcis.co.kr

User Guide –Line Impedance Stabilization Network
2
EMCIS will repair this equipment free of charge if a malfunction occurs within 2 years
after shipment due to a manufacturing fault, provided that warranty is rendered void
under any or all of the following conditions.
The fault is outside the scope of the warranty conditions described in the
operation manual.
The fault is due to disoperation, misuse, or unauthorized modification or repair
of the equipment by the customer.
The fault is due to severe usage clearly exceeding normal usage
The fault is due to improper or insufficient maintenance by the customer.
The fault is due to natural disaster including fire, flooding, and earthquake, etc.
The fault is due to use of non specified peripheral equipment, peripheral parts,
consumables, etc.
The fault is due to use of non specified power supply or in non-specified
installation location.
In addition, this warranty is valid only for the original equipment Purchaser.
It is not transferable if the equipment is resold.
EMCIS will not accept liability for equipment faults due to unforeseen and
unusual circumstances, nor for faults due to mishandling by the customer.
WARRANTY
EMCIS Contact
If this equipment develops a fault, contact office of EMCIS at the address
in the operation manual, or your nearest sales or service office.

User Guide –Line Impedance Stabilization Network
3
Certificate of Compliance
Dear Sir ;
We hereby certify that the products are manufactured, inspected, and tested
according to the rule and regulation of EMCIS quality control program
based on ISO9001,version 2008.
With best regards,
EMCIS Co., Ltd.
Quality Control Dept.

User Guide –Line Impedance Stabilization Network
4
Safety Symbols
Where these symbols or indications appear on the instrument r in this manual, they have the
following meanings.
Caution
Risk of hazard which cause fire or serious damage to
the instrument or other equipment. Do not proceed
until its suitable conditions are met.
Warning
Risk of hazard which cause injury to human body or danger to
Life, if a WARING appears on the instrument, and in this manual,
do not proceed until its suitable conditions are met.
Ground without guide
Earth with guide
Please read this manual before usage
Please keep this manual with the equipment

User Guide –Line Impedance Stabilization Network
5
Contents
1.0. Introduction of LISN
2.0. Specification
3.0. Packaging
4.0. Installation
5.0. Calibration
Appendix Isolation Transformer

User Guide –Line Impedance Stabilization Network
6
1.0. Introduction of LISN
EMCIS Model Line Impedance Stabilization Network (LISN) is a channel selectable (one or
two) low pass filter network designed to isolate the equipment under test from an external
power source ; to measure conducted emission from power lines.
The LISN must maintain a characteristic impedance to the EUT and isolate the EUT from
unwanted RF signals on both the DC and AC power source while allowing the necessary
voltage and current to be delivered to the EUT.
The LISN provides a 50Ωoutput impedance for measurement of RF emissions produced by
the EUT.
The impedance versus frequency of an LISN must match the requirements of the test
specification being applied to the EUT.
Most LISN attributes are defined in CISPR 16-1.
The most widely used LISN's present a 50Ωimpedance to the EUT. The 50Ωimpedance
was selected because theoretical and empirical data have shown that the power circuitry
statistically looks like a 50Ωimpedance to standard electronic equipment and RF test
equipment is typically designed for 50Ωinput. The bandwidth is typically determined by
the operating frequency of the potential victims of the EUT's conducted emissions.
The majority of conducted emission measurements are carried out form 150 kHz to 30 MHz.
This insures that electronic equipment do not interfere with VLF, HF radio communication
systems as well as other electronic devices operating at this frequency.
EMCIS LISN has its own special parameter.
There are two type of LISN being used ; One has one line connection port with line selection
switch(or without switch) and another one has two ports linking two lines simultaneously and
continuously. To cover both cases, EMCIS LISN has two group of selection button.
In performance and operation, there are no difference comparing with currently used LISN

User Guide –Line Impedance Stabilization Network
7
2.0. Specification
Model LN2-16
Frequency Range 9KHz ~ 30MHz
Network Impedance 50/50H + 5+ 250H
Current Rating 16Amp Max
Input voltage 220VAC
Measurement lines 1Ph, 2P(L1, N)
Input Frequency DC ~ 60Hz
Dimension W355 x H145 x D325mm
Weight 8.5kg /net
Installation Indoor usage only
Temperature 0 ~ 40°C
Related Humidity 80% up to 31°C
3.0. Packing
When receive the products, please check the packing list and match it with actual items in the
package.
Please check the conditions of items ; any damage, attachment, and looks is properly good.
Description
Quantity
Remark
Main body
1 set
Serial No.
Manual
1 ea
Table 1. Standard products package
# This packing list is based on standard package
Each purchased list shall be different according to the contract.
Please contact if there are any missing parts.

User Guide –Line Impedance Stabilization Network
8
LINE IMPEDANCE STABILIZATION NETWORK
Artificia l Hand LINE SELECT
L2L1
AN A L YSIS RF MODE
Front Panel
②③④⑤
①
⑥
①EMCIS logo and Model name ②Artificial hand
③EUT power plug(CISPR16, 16A) ④Analysis BNC connector
⑤RF BNC connector ⑥mode & line section button
Rear Panel
①②
①Earth terminal ②Input power terminal

User Guide –Line Impedance Stabilization Network
9
4.0. Installation
Any use of the LISN without proper earth connection is strictly
Warning prohibited. Due to the high leakage current to ground
inherent to this type of equipment, it is necessary to install a
supplement protective earthing wire from the protective earth
terminal on the front(rear) panel of the LISN to an appropriate
earthing point of the power mains.
If the main line is equipped with the fault current protection
switch, recommended to use an isolation transformer between
main outlet and the LISNs.
4.1. Protective earth connection
LISN is provided with earth connectors in the and rear panel. The ground
connection between the LISN and the ground plate must be as short as possible and
noninductive. The earthing point should be determined by an electrican authorized
to do such work by appropriate code or law.
4.2. Main Supply
Over current protection is not provided in the LISN
Warning LISN must be connected to a power mains which has the
properly rated mains protection installed.
Input power connection is made through the properly rated power cords meet the
related specification.

User Guide –Line Impedance Stabilization Network
10
LINE IMPEDANCE STABILIZATION NETWORK
Artif icial Hand LINE SE LECT
L2L1
AN A LYSIS RF MODE
L1 L2 RF
RF INPUTI RF INPUTⅡ
MODE RFINPUT
50VDC Max±
L1 COMMON
L2 DIFFERENTIAL
RFⅡ CALIBRATE
AUDIO VOLUME
10MHz
30dB㎶
30mV Max
SA-2000 10KHz~1100MHz
10KHz~30MHz 10KHz~1100MHz
RF mode
Analysis
mode
4.3. Measuring instruments connection
It is advisable to connect the input and output connectors to
Caution their proper power lines and loads before connecting to the
measuring instrument. Otherwise, it is possible to damage the
mixer or attenuators of the test instruments due to power surges
or transients.
LISN is connected to measuring instrument, EMI Receiver or Spectrum Analyzer
through BNC connector on the front panel.
table
Ground
# Connection shall be selected between RF andAnalysis Mode
in case of use EMCIS ESA-2000 EMI/SpectrumAnalyzer
Tabla de contenidos
Otros manuales de Instrumento de medición de EMCIS
Manuales populares de Instrumento de medición de otras marcas

Endress+Hauser
Endress+Hauser Proline Promag 50 Especificaciones técnicas

Siemens
Siemens SITRANS F Coriolis FCT030 Manual de lista de piezas

KLINGER
KLINGER CMF V Series Manual de usuario

EXFO
EXFO FTB-2 Manual de operación y mantenimiento

Keysight
Keysight M8290A Manual de usuario

ADTEK
ADTEK MW-5 Manual de usuario