This is a self contained remote control operated motion activated
security device with a built-in P.I.R.with a 3600detection pattern
(Range depends on mounting height), L.E.D.indicator, and audible
arm/disarm tones. When armed, this unit willtrigger if there is
motion in the detection area. When triggered, the built-in 115dB
siren willsound for approximately 1 minutes and then reset -
provided there is no motion in the detection area (Ifmotion is still
present; the unit willcycle again and continue to do so until
disarmed). There are also input trigger terminals provided for
external sensing devices and auxilliaryoutput terminals to trigger
other devices. ARMING & DISARMING THE SYSTEM:
When arming the security system, you must wait a period of
approximately 1 minute for the sensor to set. At that time the area
is protected. This prevents false alarm~ during sensor setup and
allows time to leave the area. Allinputs (N/Oor N/C)are instant
afterarmingthe system. .
CODE SETTING:
There are 8 jumpers with a choice of (+)to center or (-)to center
for each. Alljumpers must be in one of these positions. Matchthe
jumpers in each remote with the jumpers on the main board.
FEATURES:.
-12 VOLTD.C. 1,000 mA AC/DC adaptor (INCLU~ED)
A plug-in 110VACto 12VDC power supply is included with
this unit. There is a a plug on the output of the AC/DCadaptor that
plugs directly into a jack on the connection board.
-REMOTE CONTROLS (INCLUDED)
2 programmable remote controls ~re provided.There are 2
buttons on the remote: Button #1 arms the unit, button #~
Disarms the unit. See "Code Setting" for coding instructions.
-AUXILLIARY TRIGGER INPUT (N/O)
This input is only active when alarm is
armed. A normally open dry contact input is
provided at terminals 4 &6 to allowthis system
to be activated by a normally open device such
as: Magnetic contact, panic switch, moisture
detector, pressure mat, etc.; this also allows the
unit to be triggered by any other system
providing a dry N/Orelay output. Unitwillreset
after approximately 2 minutes if circuit is re-
opened (Or unit is disarmed), if not the unit will
cycle again and continue to do so until contact
is broken or unit is disarmed.
AUX.TRIGGER
INPUT
4 5 6 7
8V G T 12V
V N R V
C DID
CG D