2
1. Important instructions
The manual is for the full version of WGT, separated into
the parts assembly with and without tools.
- Before starting installation, check if the end of the
microduct is clean from any kind of dirt pollution and
lubricants. Also check carefully inside of microduct on
such contamination, to avoid application problems later.
- The end of a microduct need a straight, vertical, clean
cut with a tool recommended by duct manufacture.
- Due to tolerances of the outside diameter of the
microduct, different force may appear for installing the
WGT body onto the duct.
1.1 Mounting the WGT without tools on an empty
microduct
The WGT with sealing gasket can be used as sealing blind
plug for empty microducts.
1.2 Select the appropriate size of WGT according to
the diameter of microduct and size of sealing gasket to
fit the cable diameter which will be installed later
1.3 Insert sealing gasket with cone side into the
microduct, blind plug pointing towards the WGT.
1.4 Slide WGT over the blind plug and push it onto
the microduct
1.5 Push WGT on the microduct until the edge of
the duct is at least flush with the ring marking on WGT
body (arrows). This ensures tightness of WGT.
Note: To improve tightness and tensile strength on
microduct, rotate WGT ¼ turn clockwise.