Elettrotest 99112103 Manual de usuario

02/02/22 CPS_Parameters_00_ User Manual 2
INDEX
1. VERSION.......................................................................................................................................3
2. START-UP SEQUENCE...................................................................................................................3
2.1. INTRODUCTION .............................................................................................................................. 3
2.2. CPS POWER SOURCE: DESCRIPTION OF DISPLAYED INFORMATION ............................................. 3
2.2.1. POWER SOURCE AND FIRMWARE REVISION..................................................................3
2.2.2. POWER SOURCE CODE....................................................................................................3
2.2.3. POWER SOURCE OUTPUT RANGE (HIGH RANGE AND LOW RANGE).............................4
2.2.4. SERIAL COMMUNICATION BAUD RATE ..........................................................................4
2.2.5. COMMUNICATION PROTOCOL.......................................................................................4
2.2.6. POWER SOURCE OPTIONS..............................................................................................5
2.2.7. POWER-ON HOURS COUNTER........................................................................................5
2.2.8. END OF STARTUP SEQUENCE..........................................................................................6
3. QUICK START GUIDE –PARAMETERS SETTING............................................................................7
3.1. PARAMETERS TABLE....................................................................................................................... 7
3.2. CPS POWER SOURCE: PARAMETERS PROGRAMMING MODE....................................................... 8
3.3. CPS POWER SOURCE: PARAMETERS SELECTION AND MODIFICATION ......................................... 9
3.3.1. PARAMETERS SELECTION ...............................................................................................9
3.3.2. PARAMETERS MODIFICATION ........................................................................................9
3.3.3. SAVE AND EXIT................................................................................................................9
3.4. CPS POWER SOURCE: LIST OF PARAMETERS ............................................................................... 10
3.4.1. FACTORY SETTINGS.......................................................................................................10
3.4.2. AC/DC MODE ................................................................................................................10
3.4.3. SINGLE-PHASE/THREE-PHASE MODE ...........................................................................10
3.4.4. HIGH/LOW RANGE........................................................................................................10
3.4.5. 2-WIRE/4-WIRE SENSING..............................................................................................11
3.4.6. INTERNAL/EXTERNAL SYNC ..........................................................................................11
3.4.7. CONTINUOUS/INRUSH CURRENT .................................................................................11
3.4.8. L1 VOLTAGE ..................................................................................................................11
3.4.9. L2 VOLTAGE ..................................................................................................................11
3.4.10. L3 VOLTAGE ..................................................................................................................11
3.4.11. FREQUENCY ..................................................................................................................12
3.4.12. L1 PHASE.......................................................................................................................12
3.4.13. L2 PHASE.......................................................................................................................12
3.4.14. L3 PHASE.......................................................................................................................12
3.4.15. PHASE ROTATION .........................................................................................................12
3.4.16. SERIAL COMMUNICATION BAUD RATE ........................................................................13
3.4.17. SERIAL COMMUNICATION PROTOCOL .........................................................................13
4. REVISION INDEX.........................................................................................................................14

02/02/22 CPS_Parameters_00_ User Manual 3
1. VERSION
This manual is written for CPS firmware version CPSX 010_ and higher.
2. START-UP SEQUENCE
2.1. INTRODUCTION
This section describes the information shown on the display of your CPS, during the start-up sequence.
The start-up sequence takes 30 seconds and starts after a power-on or after a reset command.
2.2. CPS POWER SOURCE: DESCRIPTION OF DISPLAYED INFORMATION
2.2.1. POWER SOURCE AND FIRMWARE REVISION
CPS power source [Firmware revision: 1]
2.2.2. POWER SOURCE CODE
[POWER SOURCE CODE: 7]

02/02/22 CPS_Parameters_00_ User Manual 4
2.2.3. POWER SOURCE OUTPUT RANGE (HIGH RANGE AND LOW RANGE)
[OUTPUT HIGH RANGE: FROM 0 TO 300.0V, OUTPUT LOW RANGE: FROM 0 TO 150.0V]
2.2.4. SERIAL COMMUNICATION BAUD RATE
[BAUD RATE: 9600 bit/s]
2.2.5. COMMUNICATION PROTOCOL
[COMMUNICATION PROTOCOLO: ELETTROTEST (proprietary)]

02/02/22 CPS_Parameters_00_ User Manual 5
2.2.6. POWER SOURCE OPTIONS
[POWER SOURCE OPTIONS: 6]
2.2.7. POWER-ON HOURS COUNTER
[POWER-ON HOURS: 0]

02/02/22 CPS_Parameters_00_ User Manual 6
2.2.8. END OF STARTUP SEQUENCE
The display will switch from 7 to 9. After that, your CPS is ready to operate.

02/02/22 CPS_Parameters_00_ User Manual 7
3. QUICK START GUIDE –PARAMETERS SETTING
3.1. PARAMETERS TABLE
PARAMETERS
FACTORY SETTINGS
USER SETTINGS
AC/DC mode
AC
Single-phase/three-phase mode
3PH
High/low range
HIGH
2-wire/4-fire sensing
2W
Continuous/Inrush current
INRUSH
R voltage
0
S voltage
0
T voltage
0
Frequency
50
R phase
0
S phase
120
T phase
240
Phase rotation
L
Baud rate
1200
Serial comunication protocol
Elettrotest

02/02/22 CPS_Parameters_00_ User Manual 8
3.2. CPS POWER SOURCE: PARAMETERS PROGRAMMING MODE
To check if the machine has the programmable parameters capabilities, check the display at the turn on, if
CPSr appears in the Voltage display, the device is programmable.
In order to activate the parameters programming mode, after the end of power source initialization, press
and hold the REMOTE button for more than 5 seconds.
During parameters programming mode the power source output is powered off.
During parameters programming mode, all the parameters’ values can be checked and modified.
In case of no action for more than 3 minutes, the programming mode ends and the power source comes
back to the normal operation.

02/02/22 CPS_Parameters_00_ User Manual 9
3.3. CPS POWER SOURCE: PARAMETERS SELECTION AND MODIFICATION
3.3.1. PARAMETERS SELECTION
It’s possible to scroll the parameters by pressing the REMOTE button repeatedly.
3.3.2. PARAMETERS MODIFICATION
By rotating the knob, it’s possible to modify the selected parameter.
3.3.3. SAVE AND EXIT
In order to save the changes, the following steps have to be followed:
•Set the SAVE parameter to YES
•Press the REMOTE button for more than 5 seconds.
When the programming mode ends, the power source is reset and reconfigured following the new settings.
If the previous steps are performed without setting SAVE parameter to YES (SAVE = NO), the programming
mode ends without reset action, and the power source comes back to the previous settings.

02/02/22 CPS_Parameters_00_ User Manual 10
3.4. CPS POWER SOURCE: LIST OF PARAMETERS
During programming mode, the following parameters can be modified, refer to the manual for the
information about the parameters:
1. FACTORY SETTINGS
2. AC/DC MODE (ONLY FOR SINGLE-PHASE APPLIANCE WITH INSTALLED OPTION DC)
3. SINGLE-PHASE/THREE-PHASE MODE (ONLY FOR THREE-PHASE POWER SUPPLY)
4. HIGH/LOW RANGE
5. 2-WIRE/4-WIRE SENSING
6. INTERNAL/EXTERNAL SYNC
7. CONTINUOUS/INRUSH CURRENT (ONLY ON THE MACHINE WITH THIS CAPABILITIES)
8. L1 VOLTAGE
9. L2 VOLTAGE (ONLY FOR THREE-PHASE POWER SUPPLY)
10. L3 VOLTAGE (ONLY FOR THREE-PHASE POWER SUPPLY)
11. FREQUENCY
12. L1 PHASE (ONLY FOR THREE-PHASE POWER SUPPLY)
13. L2 PHASE (ONLY FOR THREE-PHASE POWER SUPPLY)
14. L3 PHASE (ONLY FOR THREE-PHASE POWER SUPPLY)
15. PHASE ROTATION (ONLY FOR THREE-PHASE POWER SUPPLY)
16. SERIAL COMMUNICATION BAUD RATE
17. COMMUNICATION PROTOCOL
3.4.1. FACTORY SETTINGS
In order to set a custom startup configuration “FACT = NO” must be set.
Otherwise, the startup configuration will be as factory default.
3.4.2. AC/DC MODE
3.4.3. SINGLE-PHASE/THREE-PHASE MODE
3.4.4. HIGH/LOW RANGE
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Idiomas:
Otros manuales de Instrumento de medición de Elettrotest
Manuales populares de Instrumento de medición de otras marcas

Endress+Hauser
Endress+Hauser Proline Promag 50 Especificaciones técnicas

Siemens
Siemens SITRANS F Coriolis FCT030 Manual de lista de piezas

KLINGER
KLINGER CMF V Series Manual de usuario

EXFO
EXFO FTB-2 Manual de operación y mantenimiento

Keysight
Keysight M8290A Manual de usuario

ADTEK
ADTEK MW-5 Manual de usuario