DD52R-E-RF Electronic position indicators
Data transmission via radio frequency
Models all rights reserved in accordance with the law.
Always mention the source when reproducing our drawings.
___0__
The menu function
__0___
allows the customer to choose between the options
d_tArG
or
d_to_GO
(factory detail).
Selecting
d_tArG
, when a new target position is set, the display will keep showing
the present position. If the present position differs from the target an indication will start
flashing. Turn the spindle according to the direction shown by the flashing arrows
or to get to the target position. Press the button
to see the target position
set.
Selecting
d_to_GO
, as soon as the indicator receives a new position from the
PLC, the display starts flashing, showing the distance between the actual and
the target position. To get to the target position, it is necessary to rotate the shaft
following the flashing arrows or until the number on the display becomes
zero. Once the target position is reached, the display will stop flashing showing
the actual position of the indicator. If the spindle is moved and get out of the
desired tolerance, the display will start flashing again. To visualise the actual
position while the display is flashing, keep pressed the button .
6.3.1 Target tolerance
Set the value of
P_toll
parameter to define the tollerance allowed for target (see
cap. 7.3 for detail).
6.4 Absolute / incremental measuring mode selection
Press the key to select the absolute or incremental measuring mode.
The measuring mode selected is shown on the display by the symbols:
-
ABS
: absolute measuring mode
-
REL
: incremental measuring mode
It is possible to change the key function by setting the
parameter
___0__
in the menu (see cap. 7.1).
The available options are:
-
ArCLr
(default): passing from
ABS
to
REL
the counter is set to zero.
-
Ar
: passing from
ABS
to
REL
the counter is not set to zero. In this case, the
counter is set to zero by pressing + .
-
OFF
: the key is disabled and does not allow changing the selected
measuring mode.
To program the parameters listed above, see paragraph 7.2.