This& is& the& 0*0.5& Vac& process& input.& This& input& is& used& in& junction& with& a& current& transformer.& The& input& has& a&
factory*installed& current& shunt& attached& between& terminals& 7& and& 5.&The&shunt&converts& 5& Aac& from& the& current&
transformer&to&0.5&Vac.&This&input&signal&represents&the&motor¤t&where&0&Vac&input&represents&zero&motor&
amps& and& 0.5& Vac& input& represents& maximum& motor& amps&(that& is,& the& rating& of& the& current& transformer).& This&
signal&is&displayed&on&the&Operator&Control&Panel’s&digital&display&(1).&When&5&s&is&applied,&it&is&converted&to&0.5&
Vac&and&the&AC*24&Controller&will&display&the&number&set&for&the&Display&Range&(28/29).&The&display&range&should&
be&set&to&match&the¤t&transformer.&For&example:&The&factory&default&display&range&is&set&to&100.0&for&a&100:5&
current&transformer.&If&the¤t&transformer&rating&is&50:5,&the&display&range&should&be&set&to&50.0.&
&
X!K!:&.3'!20+60+!SPKQP!R/1T!!!
This& is& the& 0*10& Vdc&output.& The& Servo& Output& terminal& (8)& is& connected& to& the& Analog& Input& of& the& attached&
MagnaValve&(orange&wire)&and&controls&the&flow&of&media&through&the&MagnaValve.&Zero&(0)&Vdc&commands&the&
MagnaValve&to&flow&0&lb/min&and&10&Vdc&commands&the&MagnaValve&to&flow&its&maximum&capability.&
&
Y!K!?*#$%&!20+60+!SLM!R/1T!!!
•When& the&mode& is& in& the& Ready& state& and& an& Enable& Input& signal& is& received,& an& Enable& Output& signal& is&
generated&at&terminal	.&
•When&the&mode&is&in&the&On&state,&an&Enable&Output&signal&is&generated&at&terminal	.&
•When&the&mode&is&in&the&Off&state,&no&Enable&Output&signal&is&generated&at&terminal	.&
The&Enable&Output&terminal&(9)&is&normally&connected&to&the&Enable&Input&wire&of&the&MagnaValve&(blue&wire).&&
&
QL!K!C%#.<!B&,&+!SLM!R/1T!!
When&a&24&Vdc&signal&is&temporarily&applied&to&the&Alarm&Reset&terminal&(12),&all&alarms&will&be&reset.&If&a&constant&
24& Vdc& signal& is& applied& to& the& Alarm& Reset& terminal& (12),& the& alarms& will& be& held& in& the&reset& state,& essentially&
disabling&them.&
&
QZ!K!C%#.<!J4;O!!
The&Alarm&High&relay&contact&(13)&is&a&normally&open&relay&contact.&The&Alarm&High&relay&contact&(13)&will&close&if&
the&Process&Input& (6/7)&is& higher&than&the& Setpoint& value&(8)&plus& the&Alarm&Band&value&(4)&for& a&duration&longer&
than&the&Alarm&Delay&(17).&The&Servo&On*Off&(20)&must&be&on&for&alarms&to&work.&
&
QM!K!C%#.<!)'<<'*!!
A&common&connection&to&all&relays.&
&
QW!K!C%#.<!A'5!
The&Alarm&Low&relay&contact&(15)&is&a&normally&open&relay&contact.&The&Alarm&Low&relay&contact&(15)&will&close&if&the&
Process&Input&(6/7)&is&lower&than&the&Setpoint&value&(8)&minus&the&Alarm&Band&value&(4)&for&a&duration&longer&than&
the&Alarm&Delay&(17).&The&Servo&On*Off&(20)&must&be&on&for&alarms&to&work.&
&
QU!K!7%'5!2[!!
The&Flow&OK& relay&contact&(16)&is&a&normally&open&relay&contact.&The&Flow& OK&relay&contact&(16)&will&close&if&the&
Process& Input& (6/7)& is& at& the& Setpoint& within& the& Alarm& Band& (4)& and& will& remain& closed& for& the& duration& of& the&
blasting/peening&cycle.&If&the&Process&Input&(6/7)&goes&higher&or&lower&than&the&Setpoint&value&(8)&plus&the&Alarm&
Band&value&(4)&for&longer&than&the&Alarm&Delay&(17),&the&Flow&OK&relay&contact&(16)&will&open&and&remain&open&until&
the& alarms& are& reset.& The& Servo& On*Off& (20)& must& be& on& for& any& of& the& alarms& to& work& (press& the& Servo& On*Off&
button&(20)&and&ensure&the&Servo&On&LED&(9)&is&lit).&
&