4
4EN EWF1 Manual v.1.0
3.2. Typical Multi-Story or Split-Level House
Install a wireless smoke detector on the ceiling or wall inside each
bedroom and in the hallway outside each separate sleeping area. If
a bedroom area hallway is more than 9 meter long, install a wire-
less smoke detector at each end. Please install a wireless smoke
detector on the top of a rst-to-second oor stairwell.
LEGEND:
Minimum required smoke detector locations.
Recommended additional smoke detector locations
Bedroom Bedroom
Basement
Living
Room
Dining
Room
3
3.3. Incorrect EWF1 Placement
DO NOT place EWF1 in the following locations:
• Nearappliancesorareaswherenormalcombustionregularlyoccurs(kitchens,nearfurnaces,hotwaterheaters).Usespecialized
wireless smoke detector with unwanted alarm control for this areas.
• Inareaswithhighhumidity,likebathroomsorareasneardishwashersorwashingmachines.Installatleast3metersawayfromthese
areas.
• Nearairreturnsorheatingandcoolingsupplyvents.Installatleast1meterawayfromtheseareas.Theaircouldblowsmokeaway
from the detector, interrupting its alarm.
• Inroomswheretemperaturesmayfallbelow5oC or rise above 45oC.
• Inextremelydusty,dirty,orinsect-infestedareaswherelooseparticlesinterferewithwirelesssmokedetectoroperation.
ATTENTION: Incorrect placement will result in a decrease of operational eectiveness.
4.INSTALLATION
1. Detach the mounting plate by turning it counter-clockwise from
the back of EWF1 (see Fig. No. 5).
2. Secure the mounting plate to ceiling or wall with mounting
screws.(see Fig. No. 5).
3. Lift to open the battery pocket door (see Fig. No. 7)
4. Insert the battery into the battery pocket considering the po-
larity terminals indicated on the enclosure of EWF1. Ensure the
battery is securely connected. Red LED may ash briey when
the battery is being installed.
5. Close the battery pocket door by snapping it into place.
6. Position the smoke detector to the mounting plate by turning
it clockwise to lock into place. Note that the device will not lock
into the mounting plate without the battery being present in
the battery pocket.
7. Push the TEST button to verify if the wirless smoke detector is
operational. See 4.1. Testing EWF1.
8. Bind the device to the alarm system using ELDES Conguration
Tool software. Open Wireless Device Management section
and enter a 8-digit wireless device ID located on the EWF1
enclosure and click the Add button (see Fig. No. 6). The device
can also be bind by sending a corresponding command via SMS
text message. For more details, please refer to the software‘s
HELP section and ELDES alarm system installation manual.
9. Upon the successful binding process, EWF1 device icon be-
comes visible in Wireless Device Management section as
well as Battery Level and Signal Level (see Fig. No. 6).
10. EWF1 wireless smoke detector is ready for use.
Mounting slot
Screws
Battery pocket door
Mounting plate
5
NOTE: If you are unable to bind the wireless device, please restore the parameters of the wireless device to default and try again. See
chapter 5.3. Restoring Default Parameters for more details.