8
Programming with EHC Smart kit
To program your eco SAVE heater with the eco
SAVE Smart Wi Kit, you must pair the radiator to
the gateway. First you must activate the pairing-
discovery mode of the eco SAVE Smart gateway.
Details of this can be found in the Smart gateway
instruction manual.
Once this is done press the CONFIG button on
the radiator and use the + or - key until the RF icon
ashes. Press OK and ‘Link’ together. An antenna
icon will appear in the top right of the screen when
connected.
Another way to pair the radiator is to press the
OK button for 3 seconds while the radiator is in
one of the main modes (OFF, AUTO, MANUAL).
Your Eco SAVE heater is now ready to accept
program instructions from the eco SAVE Smart
Gateway.
If the radiator has been linked to the gateway
and for some reason communication is lost, the
Link icon disappears and the antenna starts
ashing.
Keypad Locking (Anti-Tamper)
The keypad can be locked to prevent any
unauthorised person (children, people in public
places, nurseries, ofces, hotels etc.) altering the
settings of the radiator. To lock the keypad depress
and hold the + and – buttons at the same time for
3 seconds until “bloc” appears on the screen. Any
button presses will be ignored and “bloc” will be
display on the screen.
To unlock keyboard, once again press and
hold + and - for 3 seconds until the word ‘bloc’
disappears.
When the keypad is locked the radiator will
still receive communications from the eco SAVE
Smart Gateway.
Advanced Engineer settings
To enter the advanced settings mode, press
CONFIG while the radiator is in one of the main
modes (OFF, AUTO, MANUAL). The following
window will appear:
Now press the CONFIG button for 5 seconds
and C1 appears on the screen.
To select one of the three advanced settings (C1
to C3) use the +/- keys and choose the required
mode by pressing OK. The advanced settings are:
1. C1-> Choose ºF or ºC
2. C2-> Choose type of control
3. C3-> Temperature Compensation
Degrees Fahrenheit or Celsius (C1)
Select ºC or ºF with the +/- keys and conrm
with OK button.
Type of Control (C2)
You access the setting mode control, showing the
type of control currently used. There are 4 types
of control PID, hysteresis of 0.25ºC, hysteresis
of 0.35ºC, hysteresis of 0.50ºC and hysteresis of
0.75ºC.
To change type of control press +/-. Conrm with
OK.
The screens shown are:
Temperature Compensation (C3)
When in this mode the display will show offset
adjustments. The measured temperature is
displayed once taken into account the offset. With
the +/- keys offset can be changed and conrmed
with OK. Temperature compensation can be
adjusted up to +/- 3°C.