English Page 3
Deutsch Seite 16
Français Page 30
Italiano Page 44
Español Página 58
Português Sida 72

3
Note:
The current operating instructions, the EU
Declaration of Conformity and the Ex-certicate
can be downloaded from the relevant product
page at www.ecom-ex.com, or alternatively they
can be requested directly from the manufacturer.
Content
1. Application ............................................................... 4
2. Safety precautions ................................................... 4
3. Faults and damage .................................................. 4
4. Safety regulations.................................................... 5
4.1. Special requirements for use in ex-hazardous area....
5
5. Safety instructions................................................... 6
6. Ex-Data..................................................................... 6
6.1. ATEX ...................................................................... 6
6.2. IECEx ..................................................................... 6
7. Technical specications........................................... 7
8. Functional description / operating instructions...... 8
8.1 Assembly of the Lite-Ex PL 10e............................. 8
8.2 Getting started ....................................................... 8
8.3 Battery replacement.............................................. 9
Battery replacement.................................................... 9
8.4 Cleaning the ring switch ........................................ 9
8.5 LED replacement ................................................. 10
8.6 Replacing the protective disc............................... 10
8.7 Assembling the belt clip ...................................... 11
9. Repairs ................................................................... 12
10. Cleaning, maintenance and storage.................... 12
11. Disposal................................................................ 13
12. Warranty and liability........................................... 14
13. EU Declaration of Conformity.............................. 14
14. EU-type examination certicate .......................... 15

4
1. Application
The Lite-Ex PL 10e is a compact, robust and easy-
to-use LED ashlight for industrial application in
Ex-hazardous areas classied as Zone 2, 1 and 0,
as well as Zone 22, 21 and 20, in accordance with
directive 1999/92/EC (ATEX).
2. Safety precautions
These operating instructions contain information
and safety regulations which are to be observed
without fail for safe operation in the described
conditions. Non-observance of this information
and these instructions can have serious
consequences or it may violate regulations.
Please read these operating instructions
carefully before starting to use the unit!
In case of any doubt (in the form of translation or
printing errors) the English language operating
instructions shall apply.
3. Faults and damage
If there is any reason to suspect that the safety of
the unit has been impaired, it must be withdrawn
from use and removed immediately from the Ex-
area. Measures must be taken to prevent it from
being restarted accidentally.
We recommend that the unit is returned to the
manufacturer for inspection.
The safety of the unit may be compromised, if,
for example:
• there is visible damage to the housing.
• the unit has been subjected to excessive loads.
• the unit has been improperly stored.
• the unit has been damaged in transit.
• unit markings or inscriptions are illegible.
• malfunctions occur.
• permitted limit values have been exceeded.

5
4. Safety regulations
Use of this unit assumes that the operator
observes the conventional safety regulations
and has read the certicate in order to eliminate
faulty operation of the unit.
The following safety regulations must also be
observed with:
• The unit must not be opened within the Ex-
area.
• The batteries must only be changed outside the
Ex-area.
• Additional or spare batteries must not be
carried in the Ex-area.
• Only type-approved batteries types may be
used.
• Only spare sealing rings and discs of ecom
instruments are allowed.
• Only accessories approved by ecom
instruments GmbH may be used.
• Prevent the unit from coming into contact
with aggressive acidic or alkaline solutions.
• Do not open the inside torch head.
4.1. Special requirements for use in ex-
hazardous area
• Storing of the torch is prohibited!
• After changing the batteries or the
sealing rings always check to make
sure that the sealing rings and threads are
clean and in good condition.
• Before using the lamp in the Ex-
hazardous area and in order to ensure
the IP rating, please check that all
parts of the unit are hand tightened up
to the stop – being careful not to over-tighten.

6
5. Safety instructions
Caution! Strong light may blind other people.
• Do not look directly into the light.
• Do not shine the light directly into the eyes of
other people.
6. Ex-Data
6.1. ATEX
EU type examination certicate:
EPS 16 ATEX 1 170 X
Ex-marking: †II 1 G Ex ia op is IIC T4 Ga IP65
†II 1 D Ex ia IIIC T130° Da IP65
Ambient temperature: -20°C ≤ Ta ≤ +50°C
Approved for Zone 2,1 and 0, device group II,
explosion group IIC, temperature class T4.
Approved for zone 22, 21 and 20, device group
II, explosion group IIIC, maximum Temperature
130°C.
6.2. IECEx
IECEx Certicate of Conformity no.:
IECEx EPS 16.0074X
Ex-marking: Ex ia op is IIC T4 Ga IP65
Ex ia IIIC T130°C Da IP65
Ambient temperature: -20°C ≤ Ta ≤ +50°C
Approved for Zone 2, 1 and 0, device group II,
explosion group IIC, temperature class T4.
Approved for zone 22, 21 and 20, device group II,
explosion group IIIC, maximum Temperature
130°C.

7
7. Technical specications
Ambient temperature Ta: -20 °C ... +50 °C
Storage temperature: -30 °C ... +60 °C
Batteries / power supply: 3 x LR03
according to
IEC, AAA
Lamp: High performance LED:
3000 lx
Luminosity: 3000 lx
(at a distance of 1 m)
Luminous ux: 64 lumens
Operating time: approx. 55 hours
Dimensions: 147 x 36 x 36 mm
Weight: approx. 120g
(with batteries)
IP protection class: IP 65 / IP 67
ESD protection: Anti-static housing
CE-designation: 00102
Table with type-tested batteries:
Manufacturer Model
Duracell Industrial
Panasonic Pro Power
Panasonic Powerline
Varta Industrial Alkaline 4003
Varta Max Tech 4703
Eveready Energizer E92
Table 1
Table of approved sealing rings and
protective discs
Manufacturer Model
ecom Sealing ring type PL 10
ecom Replacement disc PL 10

8
8. Functional description /
operating instructions
Please read these operating instructions
carefully so that you are familiar with, and are
able to use, all of the functions of your
Lite-Ex PL 10e. For your own safety and
information please read the instructions on the
following pages carefully!
8.1 Assembly of the Lite-Ex PL 10e
Thread-forming screw for
plastic 20 x 10 T6
Belt clip
Flashlight body
Ring switch
Sealing ring 22.8 x 1.5
LED housing
Sealing ring 22.76 x 2
Disc
Lamp head
Fig. 1
8.2 Getting started
The supplied batteries must be inserted to
begin with (outside the Ex-area). In order to be
able to use the ashlight in the Ex-area it must
be ensured that the lamp head and the body of
the ashlight are screwed together tightly. The
ashlight can then be switched on by lightly
rotating the yellow ring switch clockwise.

9
8.3 Battery replacement
The batteries should be replaced if the level of
luminance is no longer deemed to be satisfactory.
It is advisable to change all 3 batteries at the
same time. Only the appropriate, approved types
of batteries may be used (refer to the table with
details of the type-tested batteries under point
7: Technical specications). To replace the
batteries grasp the lamp head rmly, twist the
body of the ashlight (incl. ring switch) anti-
clockwise and then remove it. The batteries can
then be removed from the battery compartment
and exchanged. After inserting the new batteries
(observe the correct polarity) the body of the
ashlight can be screwed back on. Please make
sure the ashlight has been screwed together
completely before switching it on again.
Battery replacement
- Only use type-tested batteries (see the table
under point 7: Technical specications).
- Always replace all batteries simultaneously.
- Pay attention to the correct polarity.
- Dispose of depleted batteries in an appropriate
and environmentally friendly manner!
- When changing the batteries examine the
threads and seals for cleanliness and signs of
damage.
8.4 Cleaning the ring switch
A non-contacting ring switch is used to switch
on the Lite-Ex PL 10e (see description above).
Dirt and moisture do not impair the switching
function. The ring switch is easy to clean if
excessive amounts of dirt and grime have made
it difcult to turn. Start by unscrewing the lamp
head. (See point 8.3 Battery replacement). The
ring switch can now be removed and cleaned.

10
When it has been cleaned replace the ring
switch and rotate it until it engages rmly in
place (magnet must be positioned on the shaft -
ecom address side). The lamp head can then be
screwed back onto the ashlight.
8.5 LED replacement
The Lite-Ex PL 10e is equipped with a long-
life LED bulb. Under normal conditions it is
not necessary to change the LED. If, however,
the torch is defective or the brightness of the
torch has diminished, it should be sent to ecom
instruments for inspection or repair. The LED
housing should not be opened!
Manipulating the torch head or LED on your own
poses a risk to the safety of the ashlight and is
not permitted.
8.6 Replacing the protective disc
The LED housing is protected by the surrounding
housing head and an additional protective disc,
which is located over the opening where the
beam is emitted. The disc is made of high-quality
material. Should, however, the disc break, it is
possible to replace it. To do this grasp the body of
the Lite-Ex PL 10e and the ring switch and then
carefully unscrew the lamp head by turning it
anti-clockwise. To unscrew the lamp head from
the LED housing use an Allen key (AF4) to secure
the LED housing in place (see Fig. 2) and unscrew
the lamp head. The protective disc can now be
replaced (only use original ecom protective
disc). The LED housing should then be cleaned
thoroughly (Please observe point 11) and the
sealing ring checked for signs of damage. If the
sealing ring exhibits any damage, it should also
be replaced (the sealing ring is set in a groove
under the protective disc). When replacing the
Tabla de contenidos
Idiomas:
Otros manuales de Flash de Ecom