7
Replacing the Warewash Additive
•Power Off system
•Remove suction line and discard used
additive bottle
•Unscrew cap on new additive bottle
and break the seal
•Place new additive bottle in system
and insert suction line
•Power On system and press “Reset”
button
Warewash Additive (SKU A-1060) can be
found at the EcoloxTech Online Store:
http://store.ecoloxtech.com
Electrolyzed water contains small quantities of hydrogen gas (H
2
chlorine dioxide gas (ClO2), and ozone gas (O3) that is released from
solution into the air. These gases, if accumulated, can be explosive.
Electrolyzed water contains free chlorine molecules. Free chlorine
molecules have the potential to form chlorine gas (Cl2) when the pH
of the solution becomes acidic. Chlorine gas, if inhaled, can cause
respiratory irritation or injury and is a health risk. Equipment must be
installed in a well ventilated area to avoid the accumulation of gases.
Do not install equipment near heat sources over 400°C (750°F)
Electric Shock and Fire Risks
Only use certified outlets. Do not place the equipment in water or
allow the equipment to be exposed to external sources of water. Do
not operate equipment if electric cord is damaged. Do not operate
equipment in environments of relative humidity greater than 95%. In
the event of an electric shock or fire, equipment must be removed
from the power source immediately.