EcoForce Eliminator Elite Manual de instalación

Operations Manual
Electric Heat Systems
855-4-ECOFORCE
www.EcoForceHeatSystems.com
www.HotelBedBugHeaters.com
www.BuyBedbugHeaters.com
EcoForce Heat Systems, LLC®
855-432-6367
2432 W. Peoria Ave Ste 1187
Phoenix, AZ 85029
PLEASE READ AND SAVE THESE INSTRUCTIONS

INDEX:
Introduction ………………………………………………..………………………………………. 2
Safety Instructions .……………………………………………………………………………… 2,3
EcoForce Pro R-26 ……………………………………………………………………………… 4-6
EcoForce Eliminator …………………………………………………………………………….. 7-9
EcoForce Pro-R52 ……………………………………………………………………………. 10-12
Double Universal Air Mover Heater ……………………………………………………..……13,14
Temperature Settings ………………………………………………………………………….…..16
Best Practices …………………………………………………………………………………. 16,17
Warranty …………………………………………………………………………………………… 18
1

Introduction
Thank you for purchasing your EcoForce Heat Systems® heater! EcoForce Heat Systems is proud to bring a series
of innovative products geared toward fighting the ever growing bed bug population. Our goal is to incorporate the
most advanced technology in today’s market to provide property owners and service professionals alike the ability to
kill bed bugs with heat. Our bed bug heat systems offer affordability, excellent performance, compact design, and
ease of use.
Safety Instructions
Read this owner’s manual carefully before using your pest control electric system! Warning:
Ignoring these safety precautions may result in personal injury.
Never use your heater in conditions exceeding 140ºF.
Never set the thermostat control to higher than 140ºF.
Never use an extension cord smaller than 12 gauge or longer than 100’.
2

Safety Instructions (Cont’d)
Always check building circuits for proper grounding before plugging in your heater.
Never drop or bounce. Internal damage may occur.
Never clean or service your heater while plugged into a live electrical power source.
Never operate in standing water.
Always wear rubber gloves and boots when operating in damp conditions.
Always keep the air inlet & outlet clear of any obstructions and loose material. Never operate the EcoForce
Eliminator Elite or 52K without the fan on. Never operate the EcoForce Pro-R26 without the fan attached.
Never operate your heater with a loose cord connection or damaged power cord(s).
Never connect power from different buildings to the heater.
3

4
ECOFORCE Elite 8
Specifications:
NEC® Compliant
Yes
UL® Listed
Yes
Amps Per Heating Element
8
Total Amps
64
Volts
120VAC
WATTS Per Heating Element
960
Total WATTS
7,680
BTU’s
26,190
Fan
Yes
Air Volume
2,700 CFM’s
Adjustable Thermostat Controlled
Yes, Digital
Max Temperature Setting
132ºF
Weight
42lbs
EcoForce Elite 8

Operating Your EcoForce Elite 8
Unpack & inspect your EcoForce Elite 8 for damage – Do not use if damaged. Check all heating
elements to make sure everything works and nothing was damaged from shipping. If damaged from
shipping do not use and contact us immediately at 480-304-5649.
Your EcoForce Elite 8 heater has Eight (8) 120volt plug-ins for the heat elements, four (4) located on each
side of the heater. Each heating element is 8 amps or 960 watts. Two (2) heating elements can be plugged
into a 20 single amp circuit. With (4) 20 amp circuits you can achieve full power of your EcoForce Elite
8.
If needed, you can use a 240 volt single phase splitter box to supply power to the heater via a 240 volt
electric dryer or range outlet. You can also use our hotel air conditioner splitter (A/C Pro Splitter) to
power (4) of the heating elements. When using the hotel air conditioner splitter all four (4) receptacles
must be used and must draw identically equal power. Do not plug one of the connections from the
splitter into the inlet plug-in with the green indicator light. This plug-in also provides power to the
switches and thermostat controller and draws slightly more power than the rest.
5

Operating EcoForce Elite 8 (Cont’d)
Step 1- Using a 12 gauge extension cord, plug the heating element with the green indicator light into a
wall outlet. DO NOT plug A/C Splitter (if equipped) into the green indication element as this plug also
provides power to the Fan, ON/OFF switch and thermostat controller.
Step 2- Plug in the remaining heating elements to the power supply required for your application.
Step 3- Turn on fan via the green toggle switch on top of the heater. Note: This must be done before
turning the heater on!
Step 4- Turn on the heater by pressing the red toggle switch located on the top of the heater next to the
thermostat controller.
Step 5- Adjust thermostat setting to desired Maximum temperature. (See Instructions for Temperature
Controller on page 16)
6

7
EcoForce Eliminator Elite
ECOFORCE ELIMINATOR
Specifications:
NEC® Compliant
Yes (20 Amp Breaker)
UL® Listed
Yes
Amps Per Heating Element
12.5
Total Amps
48
Volts
120VAC
WATTS Per Heating Element
1,500
Total WATTS
6,000
BTU’s
20,460
Fan Speed
1 Speed
Air Volume
2700 CFM’s
Adjustable Thermostat Controlled
Yes, Digital
Max Temperature Setting
140ºF
Weight
39 lbs
Dimensions
21” x 11” x 22”
Heating Elements

Operating Your EcoForce Eliminator Elite
Unpack & inspect your EcoForce Eliminator Elite for damage – Do not use if damaged. Check all
heating elements to make sure everything works and nothing was damaged from shipping. If
damaged from shipping do not use and contact us immediately at 480-304-5649.
Your EcoForce Eliminator Elite has one (1) cord for the fan wrapped around the cord storage handle on
top of the unit. The power control plate located on the top left of the cord storage handle contains one (1)
Green switch for fan and thermostat operation, one (1) Red switch for activating the heating elements, and
one (1) digital thermostat. The heating element receptacle plate is located on the bottom left side of the
heater below the power control plate. There are four (4) 115volt 3 prong receptacles on the receptacle
plate for supplying power to the heating elements that are installed inside the heater in front of the fan.
Each heater receptacle is 1500 watts or 12.5 amps at 120 volts and can be safely connected to a 15 amp
120 volt circuit. If necessary, use a single phase 240 volt splitter box to supply power to the heater via a
240 volt electric dryer or range outlet. You can also use our hotel air conditioner splitter (Eliminator A/C
Splitter) to power two (2) of the heating elements. When using the hotel air conditioner splitter both plugs
MUST be used and MUST draw identically equal power. Do not plug A/C Splitter into anything other
than the heating element plug-ins or damage may occur.
8

Operating Your Eliminator (Cont’d)
Step 1 - Plug the black power cord attached to the heater into a wall outlet. This cord supplies power to
the fan and thermostat controller. You must have this cord plugged in or the unit will not operate.
Step 2 - Plug the four (4) heating elements into the appropriate power source for your application.
Important: You MUST use at least twelve (12) gauge extension cords when supplying power to the
heating elements on your Eliminator Elite heater.
Step 3 - Turn on the heaters fan by pressing the Green switch on the left side of the control plate.
Step 4 - Turn on the heating elements by pressing the red switch on the right side of the control plate.
Both indicator lights and the thermostat should be illuminated at this time.
Step 5 - Adjust thermostat setting to desired maximum temperature. (See Instructions for Temperature
Controller on page 16)
Important: If you block the inlet or the outlet of the unit the heating elements will shut-off or will not turn
on. This safety feature insures that proper minimum airflow must be maintained so the heating elements
do not overheat.
9
Este manual sirve para los siguientes modelos
3
Tabla de contenidos
Manuales populares de Calentador de otras marcas

Empire Heating Systems
Empire Heating Systems WCC65 Manual de usuario

Wetekom
Wetekom 92 86 43 Manual de usuario

Desa
Desa SPC170-F Manual de usuario

Watlow
Watlow Watrod Electric Tubular Heaters Manual de usuario

Haverland
Haverland ECO-DRY GPS Series Manual de lista de piezas

Stelpro
Stelpro ASILVC2060 Series Manual de usuario