Document NO.: RD-(558D-H04)-39-001 Version: A
Date: 2018.12.17
-
and quickly respond to it to reduce the risk of damage,
injury, or death that may result from fire, If a household
member is hard of hearing, install special smoke alarms
with lights or vibrating devices to alert occupants.
7: Smoke alarms can only sound their alarms when they detect
smoke or detect combustion particles in the air. They do not
sense heat, flame, or gas. This smoke alarm is designed to
give audible warning of a developing fire. However, many
fires are fast - burning, explosive, or intentional, and others
are caused by carelessness or safety hazards. In this circs,
Smoke may not remake the unit alarm QUICKLY
ENOUGH to ensure safe escape.
8: Smoke alarms have limitations. This smoke alarm is not
foolproof and is not warranted to protect lives or property
from fire. Smoke alarms are not a substitute for insurance.
Homeowners and renters should insure their lives and
property. In addition, it is possible for the smoke alarm to
fail at any time. For this reason, you must test the smoke
alarm weekly and replace unit every 10 years.
Do Not Install Smoke Alarms in
the Following Places:
1: Near appliances or areas where normal combustion
Regularly occurs (kitchens, near furnaces, hot water
heaters). Use specialized smoke alarm with unwanted alarm
control for this areas.
2: In areas with high humidity, like bathrooms or areas near
dishwashers or washing machines. Install al least 10feet
away from these areas.
3: Near air returns or heating and cooling supply vents. Install
at least 3 feet away from these areas. The air could blow
smoke away from the detector, interrupting its alarm.
4: In rooms where temperatures may fall below 0 or rise
above 40 .
5: In extremely dusty, dirty, or insect infested areas influence
particles interfere with smoke alarm operation.
Battery Specification:
Rating voltage: DC 1.5V
Package: AA alkaline battery
Recommend battery:
Energize: E91; Gold Peak Group: GP 15A LR6; Raymax : LR6
Replace Battery:
1: Turn the alarm body counterclockwise and take out the
alarm body from the bracket.
2: Take out the old battery from the battery box.
3: Fix the two new batteries to the battery box. Please note the
battery polarity.
4: Fix the battery into battery box, fit alarm body on bracket
and turn the alarm body clockwise.
5: Test smoke alarm using test button. The sound pattern is 3
short beeps-1.5seconds pause, repeat it. I
sound output, it means that the smoke alarm is faulty or
the installing operation is wrong, and you should gain the
correctly method of disposal through reading
.
LED indicator
1: When the alarm is running normally, the red LED will
flash 1 time per 40 seconds.
2: When the battery failure or low battery is detected, the
1 time and with a corresponding red
LED flashing 1 time per 40 seconds.
3: When the unit is fault, it will chirp once per 40 seconds.
4: When the unit is running in the silence mode, the red LED
will flash once every 8 seconds.
Note: When the units chirp 1 time per 40 second, Press the test
button, it will be paused for this warning tone for 8
hours. It can still normally detect smoke during this
period, it only remove nuisance warning tone.
Alarm silence (silence mode)
During the unit is alarming, push the test button, it will be
paused the unit alarming for approx 10 minutes. The red
LED will flash once every 8 seconds, it indicates the smoke
alarm is running into the silence mode. Smoke alarms are
designed to minimize nuisance alarms. Combustion
particles from cooking may set off the alarm if the alarm is
located close to the cooking area. Large quantities of
combustible particles are generated from spills or when
grilling/frying. Using the fan on a range hood that vents to
outside (non-recirculating type) will also help remove these
combustible particles from the kitchen. The alarm silence
(test button) is extremely useful in a kitchen area or other
areas prone to nuisance alarms.
The silence feature is to be used only when a known alarm
condition, such as smoke from cooking activates the alarm.
The smoke alarm will automatically reset after
approximately 10 minutes, if after this period, particles of
combustion are still present, the alarm will sound again.
The alarm silencer (silence mode) can be repeatedly until
the air has been cleared of the condition causing the alarm.