Eaton PV240 Manual de usuario

Eaton Grid-Tied PV Inverter
User Manual
Ver. 1.1

Eaton Corporation Page 2 Ver 1.1
Index
Important Safety Notification ---------------------------------------------3
1. Introduction------------------------------------------------------------------5
2. Limited Warranty-----------------------------------------------------------6
3. Features Overview --------------------------------------------------------6
4. Product Overview----------------------------------------------------------7
4.1 Introducing the Grid PV System ------------------------------------------------ 7
4.2 Introducing Eaton Grid-Connected PV Inverter----------------------------- 8
4.3 Dimensions and Weight----------------------------------------------------------- 9
4.4 Control and Display Overview--------------------------------------------------10
4.5 LED Indicators---------------------------------------------------------------------- 11
4.6 Control Keys and LCD Displays -----------------------------------------------12
4.7 Night backlight Button ------------------------------------------------------------13
5. Installation of Eaton Grid-Tied PV Inverter---------------------- 14
5.1 Open the packing ------------------------------------------------------------------14
5.2 Visual check the PV Inverter----------------------------------------------------14
5.3 Identify the Eaton Grid-Tied PV Inverter-------------------------------------15
5.4 Mounting Inverter ------------------------------------------------------------------18
6. Wiring Box Overview --------------------------------------------------- 25
6.1 Hardware Structures --------------------------------------------------------------25
6.2 Hardware Functioning ------------------------------------------------------------26
6.3 Maximum AC Short-Circuit Current -------------------------------------------41
6.4 Knockouts for the AC and DC wiring -----------------------------------------41
7. Connecting the PV Inverter------------------------------------------- 45
7.1 DC Wiring Connections ----------------------------------------------------------45
7.2 AC Wiring Connections-----------------------------------------------------------49
8. LCD Displays Function Tree ----------------------------------------- 56
8.1 First Level Display Menu---------------------------------------------------------56
8.2 Second Level Display Menu ----------------------------------------------------57
8.2.1 Daily, Weekly and Monthly Energy Display Menu ----------------57
8.2.2 Date and Hour Display Menu ------------------------------------------58
9. Maintenance--------------------------------------------------------------- 59
9.1 External cooling fan replacement----------------------------------------------59
9.2 Cleaning the LCD Display -------------------------------------------------------62
9.3 Install or Replace the DC/AC fuse --------------------------------------------62
10. Specifications ----------------------------------------------------------- 64
11. Trouble Shooting ------------------------------------------------------- 67
11.1 Display Message Table ---------------------------------------------------------67
11.2 Trouble Shooting Actions-------------------------------------------------------69

Eaton Corporation Page 3 Ver 1.1
Important Safety Notification
General
This user manual contains important instructions and notifications for the
Eaton grid-tie PV Inverter which must be followed during installation and
maintenance for of the inverters.
The Eaton grid-tie PV Inverter is designed and tested in order to meet
international safety requirements, but yet as with all electrical and electronic
equipment, certain precautions must be observed during the installation and
operation of the Eaton grid-tie PV Inverter.
In order to avoid personal injury during installation and daily operation of the
Eaton grid-tie PV Inverter, users must to read and follow all instructions,
cautions and warnings that are described within this manual.
Electrical Code
For all electrical installation within the United States, Eaton grid-tie PV
Inverters must follow National Electrical Code regulation in addition to any
other localized regulations. For all electrical installation in Canada, inverter
installation must be completed in accordance with applicable Canadian
standards.
Safety Instructions
This manual contains various warnings in order to minimize the hazards to
personnel and equipment. Not following the procedures correctly or abnormal
practices could result in damage to the Eaton grid-tie PV Inverter and/or other
equipment(s) that is connected to the Eaton Inverter, plus personal injury.
Preventive Regulation of Product
Inverter shall be installed by authorized personnel who have read and
understand the operation instructions. Authorized/qualified personnel are
defined in the National Electric Code. Moreover, Eaton grid-tie PV Inverters
are provided with fixed trip limits and shall not be aggregated above 30kW on
a single point of common connections.

Eaton Corporation Page 4 Ver 1.1
Safety Symbols
ELECTRICAL SHOCK
Electrical shock indicates a potential for an electrical shock if not
avoided.
WARNING
Warning indicates a potentially hazardous situation that could
result in death or serious injury if not avoided.
CAUTION
Caution indicates a hazardous situation that could result in minor
injury if not avoided.
HOT SURFACE
Hot surface indicates a hot surface during operation that could
result in a burn injury if not avoided.
IMPORTANT
Important indicates specific important/useful information that the
user should know of the system.
ESD Protection
Risk of electrical shock can occur when qualified service
personnel are dealing with the electrical components within the
PV Inverter such as wiring box. An ESD glove should be worn
during the wiring operations, replacing the fuses and installing the
components.
Tool Equipment Symbols
Multi-Meter
Multi-meter symbol indicates a multi-meter should be used for
measuring in order to ensure the proper functionality of measured
components.
Tools
Tools symbol indicates some specific tools are required during the
installing procedure.

Eaton Corporation Page 5 Ver 1.1
1. Introduction
This manual describes all the information needed to install and operate an
Eaton PV240, PV250, PV260 and PV270 grid-tie PV Inverter (“PV Inverter”).
IMPORTANT
In order to avoid problems during the install procedure, it is
recommended to read the entire user manual before starting any
install procedures.
Any improper usage may result in damage to the unit. Therefore, it is
important that all installing procedures shall be completed by qualified
personnel that are trained to install and operate PV Inverters. Moreover, this
user manual only describes the information that needed for the Eaton grid-tie
PV Inverter and does not cover any installation information relating to other
equipment installed in the PV system. The following safety instruction shall
be followed:
WARNING
It is necessary that only qualified personnel conduct the
installation and operation of the Eaton grid-tie PV Inverter.
Otherwise, risk of damage could occur to the unit or connected
property due to improper installation and/or electrical shock do
due improper actions.
ELECTRICAL SHOCK
Alternating Current (AC) and Direct Current (DC) sources are
terminated in this device. In order to prevent risk of electrical
shock during maintenance or installation, it is necessary to
ensure that all AC and DC terminals are disconnected.
HOT SURFACE
Although inverter is designed to meet international safety
standards, the surface of the inverter can become hot during
operation. Therefore, do not touch the heat sink or peripheral
surfaces during or shortly after operation.
ELECTRICAL SHOCK
Risk of electrical shock from energy stored in capacitors. Do not
remove the cover until three minutes after disconnecting all
sources of supply power and the service shall be done by
qualified personnel.

Eaton Corporation Page 6 Ver 1.1
2. Limited Warranty
Eaton grid-tie PV Inverter comes with a 10-year warranty. This warranty covers
all defects due to design, manufacturing and components.
This warranty does not cover damages resulting from:
Seal on the product is broken
Improper transportation and delivery
Unqualified persons opening the unit
Improper installation and result unit damaged
Unauthorized modification, test or repairing
Insufficient ventilation of the unit
Use and application beyond the definition in this manual
Application beyond the scope of relevant safety standards
Acts of nature such as lightning, fire, storm etc.
Repairs and/or replacement of parts or the device are made at the
manufacturer’s discretion. Defective parts or malfunction discovered during
installation should be presented in a written report for confirmation before
applying for replacement or repair. The damage report must be issued within
seven working days after receiving the PV Inverter. Manufacturer is not
responsible for damages beyond the scope of this warranty.
3. Features Overview
Max energy yield CEC efficiency of 97%
Transformer-less Design
Field selectable voltage out: 208/240/277 Vac
Wide MPPT voltage operating range: 105-500V
Integrated NEC compliant wire raceway
Integrated PV system AC / DC disconnect switch
(4) branch circuit-rated Neg and Pos fused inputs
Performance Monitoring Package
LCD display with side pushbutton for nighttime monitoring
NEMA 3R enclosure
Meets UL1741 standard and CSA 22.2, No 107.1 Standards

Eaton Corporation Page 7 Ver 1.1
4. Product Overview
4.1 Introducing the Grid PV System
The grid-connected PV system is mainly composed of four parts: the
PV-modules, the gird-tied PV Inverter, the AC-Connection Unit (the connection
Interface) and a connection to the Public Utility. When a PV-panel is exposed
to sufficient irradiation and connected to an inverter, it generates DC power.
The PV Inverter converts DC to AC and feeds in to the Public Utility via the
AC-Connection unit.
The following figure shows the general configuration for a PV Inverter a grid
PV System:
DC Power
Inverter
AC Power

Eaton Corporation Page 8 Ver 1.1
4.2 Introducing Eaton Grid-Connected PV Inverter
Eaton grid-tied PV Inverter converts direct current (DC) power generated by a
PV panel into alternating current (AC), which is compatible with the local
electrical distribution network; also called the public utility, or grid system. The
Eaton grid-tied PV Inverter is designed with a transformer less
topography. Therefore, Eaton grid-tied PV Inverters will not be suitable
with PV modules that are required to have the negative (–) or positive (+)
polarity of the PV module connected to ground. For such application,
please contact the supplier before proceeding.

Eaton Corporation Page 9 Ver 1.1
4.3 Dimensions and Weight
Measuring Weights:
Model PV238
PV240 PV250 PV260 PV270
Net Weight (lbs)
86 86 90.4 101.4 101.4
17.1 in.
33.4 in.
8.4 in.
Figure 4.3: Dimension and Weight of PV Inverter

Eaton Corporation Page 10 Ver 1.1
4.4 Control and Display Overview
Figure 4.4: Overview of Eaton PV Inverter
A. LCD Display
LCD screen displays all measured values and parameters.
B. LED Indicators
There are three indicators used to indicate the operating status.
C. Control Keys
They are three control keys available to switch between each display
menu and configure the settings for the LCD.
D. DC/AC Switch
It is a built-in disconnect switch that is used to disconnect both the DC
input and AC output power from the PV inverter.
E. Night Backlight Button
When the inverter has stopped operating at night, a night backlight
momentary
button provides startup power to the PV inverter in order to
active the LCD screen with LED backlight during the night. Therefore,
user will be able to obtain the operating information in the night.
However, the button should be immediately release pressed.
F. Handling Area
It is a carrying area that is used to lift off PV Inverter. For the lifting, two
people are required due to the size and weight of PV Inverter.
A
E
B
C
D
F
Este manual sirve para los siguientes modelos
4
Tabla de contenidos
Otros manuales de Inversor de Eaton

Eaton
Eaton PowerXL DF1 Series Manual de usuario

Eaton
Eaton ETN1000 Manual de usuario

Eaton
Eaton M-Max series Manual de usuario

Eaton
Eaton DA1-34072FB-B20C Manual de usuario

Eaton
Eaton 8 kW Air-cooled Manual de usuario

Eaton
Eaton Generator Manual de usuario

Eaton
Eaton SPS-55/125 Manual de usuario

Eaton
Eaton Matrix Telecom Inverter System Instrucciones de funcionamiento

Eaton
Eaton H-Max Series Manual de usuario

Eaton
Eaton Matrix 2000 Instrucciones de funcionamiento






















