Easy-Kleen AS152E Alternate Spec Manual de usuario

1-800-315-5533 • service@easykleen.com • www.easykleen.com
Owner's Manual
Commercial and Industrial
Cold Water Electric


2
Cold Water Electric • Rev. 17/10/2016
Easy-Kleen Pressure Systems
1-800-315-5533
This manual contains operational information that is specific for
commercial and industrial cold water, electric driven machines.
Read the following instructions carefully before attempting to assemble,
install, operate or service this pressure washer. Failure to comply with these
instructions could result in personal injury and/or property damage.
Table of Contents
IMPORTANT SAFETY INFORMATION ..................................................................................................3
SPECIFICATIONS.......................................................................................................................................6
INTRODUCTION ........................................................................................................................................8
OPERATING INSTRUCTIONS..................................................................................................................9
CHEMICAL APPLICATION......................................................................................................................10
WINTER PUMP PROTECTION ............................................................................................................... 11
GENERAL MAINTENANCE....................................................................................................................12
MAINTENANCE CHECKLIST ................................................................................................................12
GLOSSARY OF TERMS...........................................................................................................................13
COMPONENT IDENTIFICATION...........................................................................................................14
QUICK DIAGNOSTICS AND SOLUTIONS GUIDE..............................................................................21
MANUFACTURER’S WARRANTY .....................................................................................................22
CIRCUIT DIAGRAMS ..............................................................................................................................23
SERVICE MANUAL .................................................................................................................................28

3
Cold Water Electric • Rev. 17/10/2016
IMPORTANT SAFETY INFORMATION
The safe operation of our pressure washing systems is the FIRST priority of Easy-Kleen. This
will only be achieved by following the operation and maintenance instructions as explained in
this manual and all other enclosed manuals.
This manual contains essential information regarding the safety hazards, operations, and
maintenance associated with this machine. The manual should always remain with the machine,
including if it is resold.
ALL CAUTIONS AND SAFETY WARNINGS MUST BE FOLLOWED TO AVOID
INJURY OR DAMAGE TO EQUIPMENT.
THIS EQUIPMENT IS TO BE USED ONLY BY TRAINED OPERATORS AND MUST
ALWAYS BE ATTENDED DURING OPERATION.
WARNING: To reduce the risk of injury,
read operating instructions carefully
before using.
WARNING: Use protective eyewear and
clothing when operating equipment in
order to avoid personal injuries.
1. Read the instructions in this manual carefully before attempting to assemble,
install, operate or service this pressure washer. Failure to comply with the
instructions could result in personal injury and/or property damage.
WARNING: This machine exceeds 85db.
Appropriate ear protection must be
worn.

4
Cold Water Electric • Rev. 17/10/2016
.
WARNING: Risk of injury
from falls when using ladder.
6. Do not overreach or stand on anything unstable. Keep a good balance and
make sure to keep a steady footing at all times.
2. Hold firmly to the gun and wand during start up and operation of the machine.
Do not attempt to make adjustments while the trigger gun is in operation.
3. Make sure all quick coupler fittings are properly secured before operating
pressure washer.
WARNING: Trigger gun kicks
back. Hold with both hands.
WARNING: Keep water spray
away from electrical wiring.
4. All electrically powered equipment must be grounded at all times to prevent
fatal electric shots. Do not spray water on or near electrical components. Do
not touch electrical components while standing in water or when hands are
wet. Always make sure machine is disconnected from power source before
servicing.
WARNING: Risk of injection or
severe injury to persons. Keep
clear of nozzle spray.
5. High pressure spray can cause serious injuries. Never point pressurized
spray at any person or animal. Handle the spray assembly with care.

5
Cold Water Electric • Rev. 17/10/2016
WARNING: Protect from freezing.
7. It is important to keep your machine from freezing in order to keep it in its
best working condition. Failure to protect your machine from freezing may
cause damage to the machine and personal injuries may occur as a result.
8. WARNING: Keep hands clear from belt guard and other moving parts. DO
NOT OPERATE MACHINE WITH BELT GUARD REMOVED.
9. Protect high pressure hoses from sharp objects and vehicles. Inspect
condition of hoses prior to use, or serious injury could occur.
10. Do not pass acids or other caustic or abrasive fluids through the pump.
11. Do not attempt to operate this machine if fatigued or under the influence of
alcohol, prescription medications, or drugs.
12. Some of the maintenance procedures involved in this machine require a
certified technician (these steps are indicated throughout this manual). Do not
attempt to perform these repairs if you are not qualified.
If you need further explanation of any of the information in this manual,
suspend any activity involving the equipment and call our toll free
number for assistance, 1-800-315-5533.

6
Cold Water Electric • Rev. 17/10/2016
SPECIFICATIONS
Commercial Cold Water Electric
MODEL
GPM
PSI
DRIVE RPM
HP/VOLTAGE
AS152E
Alternate Spec 2.2
1500
1000
1750
2/110/1ph
15 Amps
AS2436E 3.6 2400 1750 5/220/1ph
AS253E-GP 3.5 2400 1750 5/220/1ph
AS304E 4 3000 1750 7.5/220/1ph
AS3636E 3.6 3600 1750 7.5/220/1ph
AS3035E-GP 3.5 3000 1750 7.5/220/1ph
Industrial Cold Water Electric
MODEL
GPM
PSI
DRIVE
HP
VOLTAGE
IS204FE-1 4 2000 FLANGE/COUPLING 5 220V 1ph
IS204FE-3 4 2000 FLANGE/COUPLING 5 208/440/575V3ph
IS204E-1 4 2000 BELT 5 220V 1ph
IS204E-3 4 2000 BELT 5 208/440/575V 3ph
IS304FE-1 4 3000 FLANGE/COUPLING 7.5 220V 1ph
IS304FE-3 4 3000 FLANGE/COUPLING 7.5 208/440/575V 3ph
IS304E-1 4 3000 BELT 7.5 220V 1ph
IS304E-3 4 3000 BELT 7.5 208/440/575V 3ph
IS255FE-3 5 2500 FLANGE/COUPLING 7.5 208/440/575V 3ph
IS208E-3 8 2000 BELT 10 208/440/575V 3ph
IS306E-1 5.5 3000 BELT 10 220V 1ph
IS306E-3 5.5 3000 BELT 10 208/440/575V 3ph
IS404FE-1 4 4000 FLANGE/COUPLING 10 220V 1ph
IS404FE-3 4 4000 FLANGE/COUPLING 10 208/440/575V 3ph
IS1212E-3 12 1200 BELT 10 208/440/575V 3ph
IS3606E-3 6 3600 BELT 15 208/440/575V 3ph
IS465E-3 6.5 4000 BELT 20 208/440/575V 3ph
IS505E-3 5 5000 BELT 20 208/440/575V 3ph
IS310E-3 10 3000 BELT 20 208/440/575V 3ph
IS2512E-3 12 2500 BELT 20 208/440/575V 3ph
IS3685E-3 8.5 3600 BELT20 208/440/575V 3ph
IS654E-3 4.3 6500 BELT 20 208/440/575V 3ph
IS704E-3 4 7000 BELT 20 208/440/575V 3ph
IS808E-3 8 8000 BELT 50
208/440/575V 3ph
6
SPECIFICATIONS

In-Plant Systems
MODEL GPM PSI HP VOLTAGE
IP1010E-1 10 1000 7.5 208/440/575V 3ph
IP1510E-1 15 1000 10 208/440/575V 3ph
IP2110E-1 21 1000 15 208/440/575V 3ph
IP1022E-1 10 2200 15 208/440/575V 3ph
IP4210E-2 421000 2 X 15 208/440/575V 3ph
IP3612E-1 36 1200 30 208/440/575V 3ph
IP4510E-1 45 1000 30
IP7212E-2 72 1200 2 X 30 208/440/575V 3ph
IP9010E-2 90 1000 2 X 30 208/440/575V 3ph
IP13510E-3 135 1000 3 X 30 208/440/575V 3ph
IP18010E-4 180 1000 4 X 30208/440/575V 3ph
IP2320E-1 23 2000 30 208/440/575V 3ph
IP4620E-2 46 2000 2 X 30 208/440/575V 3ph
IP6012E-1 60 1200 50 208/440/575V 3ph
IP7010E-1 70 1000 50 208/440/575V 3ph
IP6010E-1 60 1000 40 208/440/575V 3ph
IP3025E-1 25 3000 50 208/440/575V 3ph
IP4020E-1 20 4000 50 208/440/575V 3ph
7
Cold Water Electric • Rev. 17/10/2016
208/440/575V 3ph

8
Cold Water Electric • Rev. 17/10/2016
Firehouse &
Car Detailing Series
MODEL
GPM
PSI
DRIVE
HP
VOLTAGE
FD2040E 4 2000 DIRECT DRIVE 5 230V-1PH
FD3035E-GP
3.5
3000
DIRECT DRIVE
7.5
230V-1PH
FD2435E-GP 3.5 2400 DIRECT DRIVE 5 230V-1PH
Marine Series Electric
MODEL
GPM
PSI
DRIVE
HP
VOLTAGE
ES204E-A 4 2000 FLANGE & COUPLING 5 220/1PH
ES204E-A-3 4 2000 FLANGE & COUPLING 5 230/440/575V 3PH
ES304E-A 4 3000 FLANGE & COUPLING 7.5 220/1PH
ES304E-A-3 4 3000 FLANGE & COUPLING 7.5 230/440/575V 3PH
ES404-A 4 4000 FLANGE & COUPLING 10 220/1PH
ES404-A-3 4 4000 FLANGE & COUPLING 10 230/440/575V 3PH
INTRODUCTION
Thank you for selecting a quality Easy-Kleen product. We are pleased to have you included
among the many satisfied owners of Easy-Kleen cleaning machines. Years of engineering
have gone into the development of these fine products and only top quality components and
materials are used throughout. Each machine is carefully tested and inspected before leaving
our plant to ensure years of dependable performance.
To continue to receive satisfactory performance, remembering that this machine represents a
substantial investment on your part, and if properly cared for and maintained it will return this
investment many times over. As with all mechanical equipment, your machine requires proper
operation and maintenance as outlined in this manual for maximum trouble free life.
This manual has been prepared under the direction of our engineering and service technicians.
Their experience in designing, manufacturing, installing and servicing our equipment from our
company’s inception is condensed in this manual. They know what information the end user
needs in order to get the optimum performance from their pressure washer. Please read
carefully.
This manual contains information that will be specific for your pressure washer, as well as
similar models.
Carefully review any additional manuals that have been included with your system and
follow ALL ADDITIONAL OPERATING INSTRUCTIONS AND SAFETY NOTICES.
They are specific for the quality components that have been used to manufacture your
machine and are an integral part of the operating and maintenance procedures.

9
Cold Water Electric • Rev. 17/10/2016
The management & staff at Easy-Kleen are proud of the equipment that we design and
manufacture, and we thank you for making us your # 1 choice in pressure washers. If you have
any questions please do not hesitate to call us, 1-800-315-5533.
Our goal is that you will be satisfied with the performance, quality, and service you receive from
Easy Kleen and that if you need to replace this machine in years to come, you will give us the
opportunity to continue supplying equipment to your company.
PLEASE READ MANUALS CAREFULLY BEFORE USING MACHINE. EXAMINE
MACHINE AND CRATE CAREFULLY FOR SHIPPING DAMAGE OR MISSING
PARTS. REPORT PROMPTLY ANY SHORTAGES OR DAMAGE CLAIMS TO
FREIGHT CARRIER OR DEALER.
OPERATING INSTRUCTIONS
1. Perform pre-start maintenance inspection on all applicable systems prior to operating the
machine. This is essential for the safe, effective and efficient operation. You will get optimum
performance from your system ONLY if these instructions and inspections are followed. Any
indication that the pressure washing system was not operated and maintained according to these
instructions may cancel the manufacturers’ warranty.
Controls – Make sure all controls turned to the off position.
Pump – Oil level - Level the pressure washer. Be sure oil level in the pump is correct on dip
stick. If the level is low, add the correct oil to the proper level. USE ONLY SAE 30 W NON-
DETERGENT OIL OR HYDRAULIC 68. DO NOT OVER FILL.
Visually inspect all electrical components to assure they are in good condition, showing
No signs of exposure, breakage or splicing.
Visually inspect all hoses, nozzles and guns to assure they are in good condition. If
replacements are necessary they must be rated to withstand the machines operating
pressure and temperatures.
2. Attach high-pressure hose to water outlet quick connector. Attach the other end of high
pressure hose (with quick coupler) to spray gun. Ensure that quick disconnect connections are
tightly locked together. Apply a sharp pull on hose to confirm they are secured.
Attach wand nozzle specific to task requirements (i.e. chemical or pressure wash).
[Quick Coupling Operation – Pull back sleeve end and insert male end into nozzle quick coupler,
release sleeve and confirm connection by pulling on nozzle].
Este manual sirve para los siguientes modelos
47
Tabla de contenidos
Idiomas:
Otros manuales de Hidrolavadora de Easy-Kleen