
6
6
7
8
888888
888888 div.deC
div.deC
...
Cel.Cap
div.deC
Cel.sen
dead.ld
CELL4 CELL 3 CELL2 CELL1
PWR INPUT 485RELAYS ANALOG232
g
kg
lb
NET
0
~
FW1
SP1 W2
SP2
35
EXC-
EXC+34
SIG- 29
SIG+ 28
SIG- 25
SIG+ 24
EXC- 23
REF-
REF 20
SIG- 19
SIG+ 18
26
EXC+
22
EXC+
+
EXC+30
EXC-
SIG+ 32
SIG- 33
EXC-27
24Vdc
Earth
RL1
RL2
IN1
COM
COM
GND
IN2
I-
I+
GND
A+
TX
V-
B-
V+
RX
ZERO TARE MODE PRINT
g
kg
lb
NET
0
~FW1
SP1 W2
SP2
CELL4 CELL 3 CELL2 CELL1
PWR INPUT 485RELAYS ANALOG232
g
kg
lb
NET
0
~
FW1
SP1 W2
SP2
EXC-
EXC+
SIG-
SIG+
SIG-
SIG+
EXC-
REF-
REF
SIG- 19
SIG+ 18
EXC+
EXC+
+
EXC+
EXC-
SIG+
SIG-
EXC-
24Vdc
Earth
1
RL1
6
RL2
7
5
IN1
4
COM
3
2
COM
8
GND
IN2
I-
10
I+
9
GND
15
A+
16
14
TX
13
V-
12
11
B-
17
V+
RX
ZERO TARE MODE PRINT
g
kg
lb
NET
0
~FW1
SP1 W2
SP2
6
7
div.deC
...
div.deC
div.deC
CapaC
QSG_ENG_DGT4X
Complete menu
at page 4
6. Maximum scale capacity, increment and decimal point setting
Set the decimal point position and the minimum scale increment*1
( 0,001 - 0,002 - 0,005 - 0,01 - 0,02 - 0,05 - 0,1 - 0,2 - 0,5 - 1- 2- 5- 10 - 20 - 50 ).
Set the maximum scale capacity*2(max 999999 ).
Examples:
7. Theoretical calibration
Set the total load cells capacity (up to 999999).
Set the load cells sensitivity (up to 999999).
(mV/V cell1) + (mV/V cell2) + (mV/V cell3) + (mV/V cell4)
(mV/V cell1) + (mV/V cell2) + ... + (mV/V celln)
n
Insert in Cel.sen parameter, the load cells sensitivity
sum value:
For each scale to calibrate, insert in Cel.sen parameter the
average sensitivity value of the load cells:
Dead load weight (from -9999.9 to 99999.9).
*1Increment = the amount that the scale will increment by as weight is added or removed.
*2Maximum capacity = the maximum weight that can be measured using the scale you are creating.
1. Set div.deC and CapaC
(ch. 4).
2. Set in Cel.Cap the total load cells
capacity (sum of the nominal load cell
capacities).
3. Set in Cel.sen the theoretical signal
value of the load cells.
4. Enter in dead.ld step. The display
shows the theoretical dead load
value. Modify the value and/or confirm
with .
5. Save calibration (Press key many
times until save? message will
appear, then press to confirm).
For a 60000 kg scale, with 2 kg
increment:
div.deC = 2
CapaC = 60000
For a 10000 g scale, with 0,1 g increment:
div.deC = 0,1
CapaC = 10000,0
For a 3000 kg scale, with 0,05 kg
increment:
div.deC = 0,05
CapaC = 3000,00
MODE 1 “DEP.CH” MODE 2 “IND.CH”