Dilog DL9120 Manual de usuario

DL9120
DL9130EV
Multifunction
installation tester
Operating Instructions
Revision 1.2

DL9120 / DL9130 Operating Instructions
- 2 -
Figure 1 DL9120 / DL9130EV Overview

DL9120 / DL9130 Operating Instructions
- 3 -
Figure 2 Earth Continuity/Insulation Measurement
Figure 3 Voltage measurement using test probes

DL9120 / DL9130 Operating Instructions
- 4 -
Figure 4 Voltage, RCD, Zs and line impedance measurement at a
mains outlet
Figure 5 Voltage, RCD, Zs, Ze and line impedance measurement at a
distribution board

DL9120 / DL9130 Operating Instructions
- 5 -
Figure 6 Phase to phase impedance/PSC measurement (DL9130EV
only)
Figure 7 Phase rotation (DL9130EV only)

DL9120 / DL9130 Operating Instructions
- 6 -
Limited Warranty & Limitation of Liability
DI-LOG Test Equipment guarantees this product to be free from defects
in material and workmanship under normal use and service for a period
of 2 years. The period of warranty will be effective from the date of
purchase.
(c) Copyright 2022
All rights reserved. Nothing from this edition may be multiplied, or made
public in any form or manner, either electronically, mechanically, by
photocopying, recording, or in any manner, without prior written consent
from DI-LOG. This also applies to accompanying drawings and diagrams.
Due to a policy of continuous development, DI-LOG reserves the right to
alter the equipment specification and description outlined in this
publication without prior notice. No part of this publication shall be
deemed to be part of any contract for the equipment unless specifically
referred to as an inclusion within such contract.

DL9120 / DL9130 Operating Instructions
- 7 -
Table of Contents
Limited Warranty & Limitation of Liability............................................... 6
Table of Contents................................................................................... 7
Introduction............................................................................................ 9
1 User Notes....................................................................................... 10
2 Safety Notes .................................................................................... 11
3 Accessories...................................................................................... 12
3.1 Standard Accessories............................................................... 12
4 Unit Description................................................................................ 13
4.1 Identifying parts of the DL9120/DL9130EV............................... 13
4.2 LCD display .............................................................................. 14
5 Using the DL9120 / DL9130EV........................................................ 16
5.1 Power On.................................................................................. 16
5.2 Remote probe (only supplied with DL9130EV)......................... 16
5.3 Continuity Tests........................................................................ 17
5.4 Insulation Resistance Tests...................................................... 18
5.5 Voltage Measurement and Phase Rotation .............................. 20
5.6 Single Phase High Current Earth Loop Impedance / Line
Impedance....................................................................................... 20
5.7 Three Phase Line Impedance................................................... 22
5.8 Non trip Earth Loop Impedance / Line Impedance.................... 23
5.9 Auto RCD Test Sequence ........................................................ 25
5.10 Auto EV Test Sequence (DL9130EV only) ............................. 27
5.11 RCD Trip Time Tests (x1/2, x1 and x5) .................................. 30
5.12 RCD Variable Mode................................................................ 32
5.13 RCD trip current (Ramp) Tests............................................... 33
5.14 Warning / Test Active Indications............................................ 35
6 Electrical Specifications ................................................................... 36
6.1 Earth Continuity........................................................................ 36
6.2 Insulation Resistance................................................................ 36
6.3 Earth Loop Impedance ............................................................. 36
6.4 Line Impedance........................................................................ 37
6.5 RCD.......................................................................................... 37
6.6 RDC-DD (DL9130EV only) ....................................................... 37
6.7 Voltage/Frequency Measurement............................................. 37
7 Environmental Conditions................................................................ 38
8 Maintenance .................................................................................... 39
8.1 Preparing to work on the DL9120 / DL9130EV......................... 39
8.2 Securing the DL9120 / DL9130EV............................................ 39
8.3 Cleaning ................................................................................... 39
8.4 Battery Replacement................................................................ 40
8.6 Service and Calibration............................................................. 41
8.7 Spare Parts............................................................................... 42

DL9120 / DL9130 Operating Instructions
- 8 -
Disposal of Old Product
This product has been designed and manufactured with high quality
materials and components that can be recycled and reused.
Please familiarise yourself with the appropriate local separate collection
system for electrical and electronic products.
Please dispose of this product according to local regulations. Do not
dispose of this product along with normal waste material. The correct
disposal of this product will help prevent potential negative consequences
for the environment and human health.

DL9120 / DL9130 Operating Instructions
- 9 -
Introduction
The DL9120 / DL9130EV is a handheld, battery powered, multi-function
electrical installation test instrument capable of performing a
comprehensive range of tests, including:
Earth Continuity @ 200mA
Earth Continuity @ 15mA (DL9130EV only)
Insulation Resistance at 250V, 500V and 1000V
Voltage
Frequency
Phase rotation
RCD Trip Time at ½In, In and 5xIn
RCD Trip current
RCD Type A, AC and B
RDC-DD testing (DL9130EV only)
Variable RCD test currents
Non trip Zs and PFC measurement on RCD protected circuits
High current Ze and PFC on non RCD protected circuits
Phase to neutral impedance and PSC
Phase to phase impedance and PSC
Power socket wiring polarity

DL9120 / DL9130 Operating Instructions
- 10 -
1User Notes
This instrument and its operating instructions are intended for use
by trained personnel.
The following symbols are used in these operating instructions and on the
DL9120 / DL9130EV.
Warning of electrical danger!
Indicates instructions must be followed to avoid danger to
persons.
Important, follow the documentation! This symbol indicates that
the operating instructions must be consulted and adhered to in
order to avoid danger.
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Otros manuales de Equipo de prueba de Dilog
Manuales populares de Equipo de prueba de otras marcas

SMART
SMART KANAAD SBT XTREME 3G Series Manual de usuario

Agilent Technologies
Agilent Technologies BERT Serial Manual de usuario

Agilent Technologies
Agilent Technologies N3280A Manual de usuario

Vernier
Vernier Go Direct Voltage Manual de usuario

Lifeloc
Lifeloc R.A.D.A.R. Manual de usuario

Fluke
Fluke T5-600 Instrucciones de funcionamiento e instalación