3.1 LocoNet® Variables (LNCV) Table
LNCV Descripon range Default LNCV Descripon range Default
0Loconet module address 1-9999 112
Waing me aer automac polarity reversal of the track
out before a short circuit is reported to the control unit.
(Seng in 3 millisecond steps.)
32-250 48
1Firmware version (1000 = 1,000)
(Value can only be read) - - 13 Waing me before polarity reversal or short-circuit signal.
(Seng in 3 millisecond steps.) 16-250 32
3Conguraon LNCV siehe unten 92 14 Oponal switching address for polarity reversal of the out-
put 0-2048 0
6Temperature of the H-bridge in degrees °C
(Value can only be read) 0-150 - 15 Polarity reversal ON for feedback A 0-2048 0
7Current load in %
(Value can only be read) 0-100 - 16 Polarity reversal ON for feedback B 0-2048 0
8Turnout address for booster Individual switch-o 0-2048 017 Polarity reversal OFF for feedback D 0-2048 0
11
Waing me unl restart aer short circuit.
The default value corresponds to approx. one 3/4 second
(750 ms). (Seng is done in three millisecond steps.)
64-30000 244 18 Polarity reversal OFF for feedback E 0-2048 0
Bit Wert Descripon Default Bit Wert Descripon Default
0
0Not used
04
0Booster does not send a special LocoNet® message in case of
short-circuit shutdown.
16
1Not used 16
Booster sends a LocoNet® message in case of a short circuit so
that the central unit can display which booster has been
switched o.
1
0Track Out acve as soon as an input signal is detected.
05
0Track Out acve without output polarity reversal (blue LED o)
0
2
Track Out acve as soon as the GO/Stop buon of the control
unit is pressed or the connected switching address (LNCV 8) is
switched to green.
32 Track Out acve Output reversed polarity (blue LED on)
2
0Booster does not send 'GPON/GPOFF' L.NET report on short
circuit. Automac short-circuit repair is enabled. 46
0Automac polarity reversal o
64
4Booster sends 'GPON/GPOFF' L.NET report to headquarters. The
central determines when the track out is switched on again. 64 Automac polarity reversal on
30Not used 870Not used 0
8Not used 128 Not used
3.2 Descripon Conguraon LNCV
With the LNCV 3 the behaviour (short-circuit behaviour, start behaviour, automac reverse polarity, etc.) of the booster can be adapted.