Dexing DHP400 Manual de usuario

DHP400
Head-end Processor User Manual
SW Version: 2.21 Build 141.00 Apr 29 2016
HW version: 0.10.0.8
Web NMS version: 2.1
20142014
DEXIN DIGITAL TECHNOLOGY CORP. LTD.

About This Manual
Intended Audience
This user manual has been written to help people who have to use, to integrate
and to install the product. Some chapters require some prerequisite knowledge in
electronics and especially in broadcast technologies and standards.
Disclaimer
No part of this document may be reproduced in any form without the written
permission of the copyright owner.
The contents of this document are subject to revision without notice due to
continued progress in methodology, design and manufacturing. DEXIN shall have
no liability for any error or damage of any kind resulting from the use of this
document.
Copy Warning
This document includes some confidential information. Its usage is limited to the
owners of the product that it is relevant to. It cannot be copied, modified, or
translated in another language without prior written authorization from DEXIN.

Directory
Chapter 1 Product Overview.......................... 1
1.1 Outline ........................................................ 1
1.2 Features ...................................................... 1
1.3 Specifications.............................................. 1
Chapter 2 Physical Presentational Statement2
2.1 Appearance and Description .................... 2
Chapter 3 Installation Guide .......................... 5
3.1 Acquisition Check...................................... 5
3.2 Installation Preparation ............................ 5
3.3 Wire’s Connection ..................................... 7
Chapter 4 Web NMS Management................ 9
4.1 Login ........................................................... 9
4.2 Operation.................................................. 10
Chapter 5 Troubleshooting........................... 50
Chapter 6 Packing list ................................ 52

DHP400 Head-end Processor User Manual 1
Chapter 1 Product Overview
1.1 Outline
DHP400 DTV head-end processor is the new generation of intelligent headend
processing equipment. This 1-U case comes with 6 independent module slots. Each
module can be configured individually based on the applications including
encoding, decoding, trans-coding, multiplexing, descrambling and modulating
processing and the combination of all these functions. It supports multiple input
and output interfaces and signal formats. With its powerful performance and low
cost, DHP400 is especially adequate for the new generation CATV system.
1.2 Features
Support Web management, Updates via web
Support flexible combination of different type of modules
Support up to 6 modules
Redundancy power supply (optional)
Support 1 ASI output (MPTS2)
Support 2 GE output, 512 SPTS (UDP, RTSP/RTP) output from GE1, 8 MPTS
(UDP,RTP) output from GE2, Unicast/Multicast, RJ45/SFP interface
Support Web management, Updates via web
1.3 Specifications
(For each module’s parameters, please see DHP400 Head-end processor SPEC)

DHP400 Head-end Processor User Manual 2
Chapter 2 Physical Presentational Statement
2.1 Appearance and Description
Front Panel Illustration
2
3
4
5
6
7
1
1 Air Vent
2 ASI output port
3 GE1/GE2 Output: IP signal output, SFP connector
4 Reset: Reset webmaster IP address, recover it to default IP address
5 GE1/GE2 Output: IP signal output, RJ45 connector
6 NMS: network management system /CA communication, Ethernet interface
7 Indicators
1U chassis support up to 6 modules, users can freely select different module types
and freely exchange modules’ position, and here we just take one case as an
example.
Rear Panel Illustration

DHP400 Head-end Processor User Manual 3
Module Illustration:
DX504 4 ASI/IP Multiplexing Module
DX505 5 ASI Multiplexing Module
DX214 4 CVBS Encoding Module
DX202A 2 HDMI Encoding/Transcoding Module
DX202A-D 2 SDI Encoding/Transcoding Module
DX224 4 HDMI Encoding Module

DHP400 Head-end Processor User Manual 4
DX202 2 IP Transcoding Module
DX702 2 HD-SDI Decoding Module
DX316/332 16/32 QAM Modulating Module
DX308T 8 DVB-T Modulating Module
DX308C 8 ATSC Modulating Module
DX306I 6 ISDB-Tb Modulating Module
DX902 2 Tuner(DVB-S/S2) Descrambling Module
DX9122 Tuner(DVB-C) Descrambling Module
DX904 4 FTA Tuner(DVB-S/S2) Module
DX914 4 FTA Tuner(DVB-C) Module
DX944 4 FTA Tuner(DVB-T/T2) Module

DHP400 Head-end Processor User Manual 5
Chapter 3 Installation Guide
3.1 Acquisition Check
When user opens the package of the device, it is necessary to check items
according to packing list. Normally it should include the following items:
DHP400 Head-end processor
User’s Manual
Power Cord
If any item is missing or mismatching with the list above, please contact local
dealer.
3.2 Installation Preparation
When users install device, please follow the below steps. The details of
installation will be described at the rest part of this chapter. Users can also refer
rear panel chart during the installation.
The main steps of the installation include:
Checking the possible device missing or damage during the transportation
Preparing relevant environment for installation
Installing DHP400 head-end processor
Connecting signal cables
Connecting communication port (if it is necessary)
3.2.1 Device’s Installation Flow Chart Illustrated as follows:

DHP400 Head-end Processor User Manual 6
3.2.2 Environment Requirement
Item Requirement
Machine Hall Space
When user installs machine frame array in one machine hall, the
distance between 2 rows of machine frames should be 1.2~1.5m and
the distance against wall should be no less than 0.8m.
Machine Hall Floor
Electric Isolation, Dust Free
Volume resistivity of ground anti-static material: 1X107~1X1010,
Grounding current limiting resistance: 1M (Floor bearing should be
greater than 450Kg/㎡)
Environment
Temperature
5~40℃(sustainable ), 0~45℃(short time)
installing air-conditioning is recommended
Relative Humidity 20%~80% sustainable 10%~90% short time
Pressure 86~105KPa
Door & Window
Installing rubber strip for sealing door-gaps and dual level glasses
for window
Wall It can be covered with wallpaper, or brightness less paint.
Fire Protection Fire alarm system and extinguisher
Power
Requiring device power, air-conditioning power and lighting power
are independent to each other. Device power requires AC power
220V ±10% 50/60Hz or 110V ±10% 50/60Hz. Please carefully
check before running.
3.2.3 Grounding Requirement

DHP400 Head-end Processor User Manual 7
All function modules’ good grounding is the basis of reliability and stability
of devices. Also, they are the most important guarantee of lightning arresting
and interference rejection. Therefore, the system must follow this rule.
Coaxial cables’ outer conductor and isolation layer should keep proper
electric conducting with the metal housing of device.
Grounding conductor must adopt copper conductor in order to reduce high
frequency impedance, and the grounding wire must be as thick and short as
possible.
Users should make sure the 2 ends of grounding wire well electric conducted
and be antirust.
It is prohibited to use any other device as part of grounding electric circuit
The area of the conduction between grounding wire and device’s frame should
be no less than 25mm2.
3.2.4 Frame Grounding
All the machine frames should be connected with protective copper strip. The
grounding wire should be as short as possible and avoid circling. The area of the
conduction between grounding wire and grounding strip should be no less than
25mm2.
3.2.5 Device Grounding
Connecting the device’s grounding rod to frame’s grounding pole with copper
wire.
3.3 Wire’s Connection
Tabla de contenidos
Manuales populares de Hardware de computadora de otras marcas

EMC2
EMC2 VNX Series Manual del propietario

Panasonic
Panasonic DV0PM20105 Manual de usuario

Mitsubishi Electric
Mitsubishi Electric Q81BD-J61BT11 Manual de usuario

Gigabyte
Gigabyte B660M DS3H AX DDR4 Manual de usuario

Raidon
Raidon iT2300 Manual de usuario

National Instruments
National Instruments PXI-8186 Manual de usuario