Delta-T Devices FX30 Manual de usuario

User Manual for
Modem Gateway
for DeltaLINK-Cloud
Delta-T Devices Ltd
DLC-UM-1.2

Copyright
Copyright © 2019 Delta-T Devices Limited. All rights reserved.
Under the copyright laws, this manual may not be copied, in
whole or in part, without the written consent of Delta-T Devices
Ltd. Under the law, copying includes translation into another
language.
CE conformity
The CE marking identifies this product as complying with all relevant directives
in the European Union (EU). For use with the GP1, DL6 or GP2 Logger this may
include one or more of the following products:
Product
Description
Standards
Modem
FX30
Refer to Sierra Wireless FX30 Hardware
User Guide.
Solar
regulator
Steca
Solsum6.6F
2004/108/EC (EMC)
2006/95/EC (Low voltage directive)
Solar panel
BP SX series
IEC 61215
If the equipment is used with any non Delta-T products it is the responsibility of
the user to ensure the EMC compliance of any such measuring systems.
Design changes
Delta-T Devices Ltd reserves the right to change the designs and specifications
of its products at any time without prior notice.
User Manual Version: 1.2 Jul 2019
Delta-T Devices Ltd
Tel: +44 1638 742922
130, Low Road, Burwell
Fax: +44 1638 743155
CAMBRIDGE CB25 0EJ
e-mail: sales@delta-t.co.uk
U.K.
www: www.delta-t.co.uk

Contents ⚫3
Contents
Contents 3
Scope of This Document 5
Introduction 6
DeltaLINK-Cloud 6
Support for GP1, DL6 or GP2 loggers 8
Health and Safety 9
Installation 9
Batteries 9
Install Modem Gateway with a GP1, DL6 or GP2 logger 10
Requirements 10
Modem Parts 11
Parts and wiring used with GP2 Loggers 12
Parts and wiring used with GP1 and DL6 loggers 14
1: Ensure the modem is powered. 15
2: Set up DeltaLINK-Cloud 18
Wiring 26
Modem Cable Harness for GP2 logger 26
GP2 Network cabling Options with Modem 26
System Wiring for GP2 Logger with modem gateway in M-
ENCL-B2 metal enclosure 27
BX1 Modem Box Wiring Harnesses 28
DLC-BX1-SP System Wiring with GP1 Logger 29

4 ⚫Contents
SIM Card replacement 29
Warranty and Service 31
Terms and Conditions of Sale 31
Service, Repairs and Spares 32
Technical Support 32

Scope of This Document ⚫5
Scope of This Document
These instructions describe the use of a modem that
communicates with the DeltaLINK-Cloud in the following
systems:_
MD-3G-DLC: Cloud modem kit for mounting with GP2 Logger into
the M-ENCL-B2 metal enclosure.
The GP2 logger is mounted inside the metal enclosure.
3G-DLC-BX1/B: polymer Modem Box with DeltaLINK-Cloud
enabled modem and battery.
3G-DLC- BX1/SP: polymer Modem Box with DeltaLINK-Cloud
enabled modem plus solar power & battery.
The GP1, GP2 or DL6 logger(s) are mounted outside the box.
Other Documents
You may also need to refer to the following:
-GP2 User Manual
-GP1 Quick Start Guide
- DL6 Quick Start Guide
- Network Cabling for GP1 and DL6
-Deltalink 3.8 or later on-line Help
-Steca Solsum 6.6F Operating Manual
-Solar Panel Manufacturer’s Instructions
-SOL 4 Solar Panel Mounting Bracket Assembly Notes
-Sierra Wireless FX30 Hardware User Guide.
See also http://www.delta-t.co.uk/DeltaLINK-Cloud.asp
To log in go to www.deltalink-cloud.com

6 ⚫Introduction
Introduction
The Delta-T Modem Gateway is used to connect GP2, GP1 and
DL6 loggers to the DeltaLINK-Cloud.
DeltaLINK-Cloud
DeltaLINK-Cloud is a free
1
secure cloud-based service from Delta-
T Devices which allows you to upload, monitor, manage and
share your sensor data with speed and ease.
•Remote data monitoring
•Share data and collaborate
•Automatic upload
•Mobile, tablet and PC compatible
•Flexible charting and reporting
•SIM card provided
•Secure and encrypted
DeltaLINK-Cloud is a secure cloud connectivity, data management
and automatic data retrieval solution. The website lets you
monitor the status of your loggers and modem gateways, graph
and export the uploaded data and share access to data reports
with project collaborators/stakeholders.
1
Data service charges apply to data sent via the 3G modem gateway.

Introduction ⚫7
Website functionality comes for free and is accessible from most
modern internet capable devices (phone, tablets and computers).
Delta-T’s GP2, GP1 and DL6 data loggers can be connected to DeltaLINK-
Cloud using the modem gateways described in this user manual or via PC
based gateway software (Windows).
Charges do apply to data transferred via the modem SIM card.
For information about SIM card data service charges contact Delta-T
Gateway upload schedules can be customised from DeltaLINK-Cloud.
The SIM cards provided by Delta-T enable us to provide an optimum
user experience and support service.
These Smart SIM cards can connect to multiple network providers,
which improves the chance of you having a stable connection.
Logger status can be monitored and program-setting changed remotely.
Data generated by the loggers can be charted per logger or aggregated
and charted for multiple loggers. Charting is customisable and can be
saved as reports for future use –which can be shared via a link.
See https://www.delta-t.co.uk/deltalink-cloud/
and www.deltalink-cloud.com

8 ⚫Introduction
Support for GP1, DL6 or GP2 loggers
Delta-T supplies these systems fully wired up so you don’t have
to worry about wiring. The modem firmware and SIM card are
preconfigured at Delta-T with the system ready to automatically
connect to the DeltaLINK-Cloud as soon as it is powered up.
When you have registered with the cloud you first create your
own gateway and tell it which loggers are attached. Then it is
ready to use.
The modem power comes from an LBAT 4 battery shown in the
bottom of both boxes. The wiring arrangements of the two
systems shown above are slightly different. This is covered in
later sections of this manual.
MD-3G-DLC DeltaLINK-Cloud -
enabled 3G modem installed with
AGP2 logger controller in an
M-ENCL-B2 metal enclosure.
A SOL-4 solar power
charger/regulator and
LBAT4 battery are also shown.
3G-DLC-BX1/SP
DeltaLINK- Cloud - enabled modem
installed in a polymer Modem Box
This includes a SOL-4 solar power
charger/regulator and LBAT4
battery.

Health and Safety ⚫9
Health and Safety
Installation
Cover the solar panels to exclude light before starting the
installation.
Batteries
Batteries that are prone to give off explosive gases at any stage of
their charge or discharge cycle must not be mounted in the
enclosure without sufficient additional ventilation.
Do not use non-approved batteries or other battery
charger/regulators in un-ventilated enclosures.
For optimum thermal protection the Solsum solar
charger/regulator should be installed in the same housing as any
external battery.
See also Warnings in the M-ENCL-B User Manual

10 ⚫Install Modem Gateway with a GP1, DL6 or GP2 logger
Install Modem Gateway with a GP1, DL6
or GP2 logger
Requirements
MD-3G-DLC: Cloud modem kit for mounting with GP2 Logger
into M-ENCL-B2 metal enclosure
or
3G-DLC-BX1/B: polymer Modem Box with DeltaLINK-Cloud –
enabled modem and battery
or
3G-DLC- BX1/SP: polymer Modem Box with DeltaLINK-Cloud
enabled modem plus solar power & battery.
A source of power is required for the modem, such as the LBAT4
and SOL4 solar power system.
At 12V the modem’s maximum consumption is up to 600mA
when connecting and 212mA when communicating with the
DeltaLINK-Cloud servers, and 74mA maximum otherwise. The
typical value would be a lot lower than this.
Tabla de contenidos
Otros manuales de Puerta de Delta-T Devices
Manuales populares de Puerta de otras marcas

LST
LST M500RFE-AS Manual de usuario

Kinnex
Kinnex Media Gateway Manual de usuario

2N Telekomunikace
2N Telekomunikace 2N StarGate Manual de usuario

Mitsubishi Heavy Industries
Mitsubishi Heavy Industries Superlink SC-WBGW256 Manual de usuario

ZyXEL Communications
ZyXEL Communications ZYWALL2 ET 2WE Manual de usuario

Telsey
Telsey CPVA 500 - SIP Manual de usuario